Quick Tools QU959D+ User Manual Download Page 22

              

 USER MANUAL 

 

 

 

2.9.

 

Troubleshooting 

 

H-E 

Indicates that there is a problem with the heater and the heater needs to 
be

 checked or replaced.

 

S-E 

Indicates that there is a problem with the sensor and the sensor needs to 
be 

checked or replaced.

 

ERR 

Indicates that the fan is faulty and needs to be checked 

or replaced

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for QU959D+

Page 1: ...ENUNGSANLEITUNG QU959D Hei luft L tstation Hot Air Rework Station Br unlich GmbH Am Heideberg 26 D 06886 Lutherstadt Wittenberg Tel 49 0 3491 6181 0 Fax 49 0 3491 6181 18 e mail info quick tools de ww...

Page 2: ...chnischen Daten 4 1 5 Inbetriebnahme 5 1 6 Passwort ndern 8 1 7 Kalibrierung 8 1 8 Heizeinsatz wechseln 9 1 9 Fehlermeldungen 10 2 English 1 2 1 Safety Instruction 1 2 2 Characteristics 3 2 3 Specific...

Page 3: ...ten ACHTUNG Dessen Nichtbeachtung kann m glicherweise zur Verletzung des Benutzers oder zu einer Besch digung beteiligter Objekte f hren Zu Ihrer eigenen Sicherheit sollten Sie diese Hinweise einhalte...

Page 4: ...darf nicht mit scharfen metallischen Gegenst nden in Ber hrung kommen Der Hei luft Auslass muss mindestens einen Abstand von 2mm zum Objekt haben Es muss immer die passende D se entsprechend der Anwe...

Page 5: ...beaufsichtigt werden und bez glich des sicheren Gebrauchs unterwiesen wurden Netzanschlussleitungen d rfen nicht mit scharfen Kanten Hitze oder len in Verbindung kommen Besch digte Anschlussleitungen...

Page 6: ...digitale Kalibrierfunktion Automatik Standby und Ruhezustand konstante Temperatur dank geschlossenem Regelkreis automatisches K hl System leichter Handgriff 1 4 Technischen Daten Anzeige LCD Anschluss...

Page 7: ...eratur CH1 CH2 CH3 3 Speicherpl tze CH0 Manuelle Einstellung COOL Abk hlphase SLEEP Standby CAL Kalibrierung 1 5 2 Ablage f r Hei luftkolben Die Ablage f r den Hei luftkolben muss an der Station links...

Page 8: ...Hei luftkolben immer in den Ablagest nder Der Hei luftkolben wird im Ablagest nder automatisch gek hlt Sobald weniger als 100 C erreicht sind schaltet die Station in den Standby Modus In l ngeren Arb...

Page 9: ...ion im Arbeitsmodus 1 5 7 Passwort eingeben Wenn das Standard Passwort 000 nicht ge ndert wird k nnen Einstellungen ge ndert werden Wenn das Passwort ge ndert wurde dann muss es vor der nderung der Ei...

Page 10: ...eweils best tigen 9 Station aus und wieder einschalten 10 Die Station ist gesichert Es k nnen nur noch die 3 Speicherpl tze ausgew hlt werden 1 7 Kalibrierung HINWEIS Zur Kalibrierung wird das Messger...

Page 11: ...Gelbes und Oranges Kabel vom Heizeinsatz abziehen 4 Schraube am Stahlrohr entfernen 5 Gr ne Masseleitung vom Stahlrohr abziehen 6 Stahlrohr heraus ziehen 7 Halterung auf Besch digungen pr fen 8 Heize...

Page 12: ...wechseln ERR L fter pr fen ggf wechseln Wir w nschen Ihnen viel Freude und Erfolg beim Einsatz Ihrer QUICK Hei luft Station und sind gern an Ihren Anregungen f r Verbesserungen interessiert Kontaktier...

Page 13: ...014 35 EU einschlie lich deren zum Zeitpunkt der Erkl rung geltenden nderungen entspricht Folgende harmonisierte Normen wurden angewandt RICHTLINIE DES EUROP ISCHEN PARLAMENTS UND DES RATES zur Harmon...

Page 14: ...of burns on the surfaces The device is designed for brazing soft solder at different temperatures A different use is not permitted During operation and immediately after switching off do not touch th...

Page 15: ...es for a safe working environment Make sure that the device and the shelf are secure Place the tool on the shelf when not in use The use of the device by children from 8 years and persons with disabil...

Page 16: ...3 Specification Power 580W Display LED resolution 1 Airflow Max 40 min Temperature range 100 500 C Heating element Ceramic Heating element Dimension 110mm W 151mm L 180mm H Weight 1 6kg 2 4 Applicatio...

Page 17: ...e plate Make sure that the station is always switched off when plugging or unplugging the handset Failure to do so may result in damage 2 5 1 Buttons and Symbols Air volume C Temperature CH1 CH2 CH3 3...

Page 18: ...torage stand The station is now in work mode Set the desired air volume After use and during work breaks always place the hot air pen in the storage stand The hot air pen is automatically cooled in th...

Page 19: ...hen it must be entered before the settings can be changed 1 switch off station 2 Press and hold at the same time and switch on the station 3 Control tone is heard C is displayed briefly 4 The display...

Page 20: ...prox 3 5mm in front of the hot air nozzle 1 Switch on the station and remove the hot air bath from the tray set 300 C 2 When the display has stabilized measure the hot air temperature 3 press and hold...

Page 21: ...e 5 Disconnect green ground wire from steel pipe 6 Pull out steel pipe 7 Check the holder for damage 8 Detach heater insert from plug 9 Remove heating element 10 Install new heating element 11 Insert...

Page 22: ...here is a problem with the heater and the heater needs to be checked or replaced S E Indicates that there is a problem with the sensor and the sensor needs to be checked or replaced ERR Indicates that...

Page 23: ...oltage Directive 2014 35 EC including the changes which applied at the time of the declaration The following harmonised standards have been applied DIRECTIVE OF THE EUROPEAN PARLIAMENT AND OF THE COUN...

Page 24: ...SER MANUAL BEDIENUNGSANLEITUNG Br unlich GmbH Am Heideberg 26 D 06886 Lutherstadt Wittenberg Tel 49 0 3491 6181 0 Fax 49 0 3491 6181 18 e mail info quick tools de www quick tools de Version 17 08 2023...

Reviews: