Quick Charge SCP Quick Start Instructions Download Page 10

When powered up the 
LED is solid red with a 
yellow flash, and 
displaying 02. 

The battery is very low, 
and the charger is in a 
slow charge phase until 
the voltage rises to a 
safe level before full 
turn on. 

Leave connected, it may 
take hours, but if the 
voltage rises even a little 
bit, it should recover, 
and turn the charger full 
on. 

(Do not allow your 

batteries to deep 
discharge, it is the 
number one cause of 
premature battery 
failure

.) 

The charger blows it’s 
fuse, or branch circuit 
fuse/circuit breaker as 
soon as it’s switched on. 

Charger is shorted. 

Contact factory. 

The charger blows the 
branch circuit 
fuse/circuit breaker a 
short while after being 
switched on. 

The branch circuit is too 
small. 

Relocate charger to a 
branch circuit with a 
heavier rating, or 
remove other loads on 
the circuit.  

Batteries use water, get 
hot, or smell. 

One or more dead cells. 
 
 
 
 
 
 
Profile not set correctly. 

Replace batteries. If 
charging in a series 
string, it is best to 
replace all the batteries 
rather than mix new 
with old. 
 
If shallow discharging, 
check that the 
gassing/absorption 
profile is set to 

d1

 

After a full charge, the 
batteries die quickly 

The batteries are 
sulfated. 

Sometimes batteries can 
be recovered. Leave the 
charger on for some 
hours, if the voltage falls 
and the current begins to 
rise, it is a good sign 
they can recover under 
normal charging. 

Summary of Contents for SCP

Page 1: ...argers models SCP SCPX SCS SCSX SCX For Industrial Use Designed for gel wet cell AGM and Lithium Ion batteries Lithium ion applications must be factory programmed Quick Charge Corp 800 658 2841 e mail...

Page 2: ......

Page 3: ...When using multiple batteries in a series string cells become uneven during charge and discharge cycles At least once a month perform two charge cycles back to back this will give a chance for cells t...

Page 4: ...ounded to reduce the risk of electric shock 117 volt chargers are equipped with a grounding type plug 230 volt chargers are shipped without a plug Have a qualified electrician install a properly groun...

Page 5: ...oss the battery terminal or battery top Arcing or explosion of the battery can result Do not wear jewelry when working around batteries Arcing can cause severe burns The tops of the batteries and batt...

Page 6: ...re the AC cord DC output leads terminals connectors or clamps are all in good working condition Do not use the charger if there are any signs of stress or damage or if wires are cut or have damaged in...

Page 7: ...s a three stage profile for AGM batteries Bulk charging absorption cycle and maintenance F5 is for Lithium ion batteries and must be pre programmed at the factory The adjustments are d0 standard gassi...

Page 8: ...p at the desired profile The display will stop flashing and remember the setting Unplug AC power and reconnect the battery When powered back up the display will flash the changed setting and the charg...

Page 9: ...volt meter across the output of the charger there is no power coming out when I plug it in The charger must be connected to a battery to turn on The batteries don t receive a full charge On wet cells...

Page 10: ...e charger blows the branch circuit fuse circuit breaker a short while after being switched on The branch circuit is too small Relocate charger to a branch circuit with a heavier rating or remove other...

Page 11: ...s did not reach minimum voltage requirements and the charger bulk timed out The batteries are too big for the charger The batteries have defective cells and cannot make minimum voltage NOTE An occasio...

Page 12: ...zed by Quick Charge or if the charger or component have been subjected to misuse negligence or harsh environmental conditions Except those chargers designed for such conditions If returning the charge...

Reviews: