TROUBLES HOOTING

 

 

Symptom 

Cause 

Corrective  Action 

No voltage reading on 
meter  when connected 
to battery, and the LED 
flashes red/green. 
 

Connected reverse to 
battery, or not connected 
to battery.  
 
 
 
Break  in DC  cord, or 
connector.  
 
Battery too dead to 
charge.  

Correct polarity, or 
connect to battery. On 
chargers having a white 
and black wire,  white is 
positive. 
 
Have a qualified person 
make  repair. 
 
Replace. 

When switched on, the 
red LED  does not light, 
and no amps read on 
meter 

The panel mount fuse is 
blown. 
 
There is no AC power 
present at the plug. 

Replace with one having 
the same rating. 
 
Check that there is 
power at the source. If 
using an extension cord, 
check that it is not 
damaged. 

When I put a volt meter 
across the output of the 
charger there is no 
power coming out when 
I switch it on. 

The charger must be 
connected to a battery to 
turn on. 

 

The batteries don’t 
receive a full  charge. On 
wet cells, the specific 
gravity will  not rise to a 
full  reading after the 
charge has completed.  

The charger is too small 
for the battery. 
 
 
 
The charge profile  is not 
set correctly. 
 
 
The cycle needs more 
time.   
 
 
The battery is defective. 

Check that the charger’s 
output is about 10% of 
the amp hour rating of 
the battery. 
 
Recheck the dip switch 
setting. If in doubt, 
contact us. 
 
If you have a 4 position 
switch, switch #1 
position ON. 
 
Replace. 

Summary of Contents for QP

Page 1: ...Battery Chargers For Industrial Use Designed for gel wet cell AGM and Lithium Ion Batteries Lithium ion applications must be factory programmed Quick Charge Corp 800 658 2841 e mail quickcharge icnet...

Page 2: ......

Page 3: ...AC WIRING Before making AC connections refer to the requirements on the charger ID label If your charger is not equipped with an AC plug for example a 230 volt charger have a qualified electrician ins...

Page 4: ...r from the batteries when the charger is on The resulting arcing could cause the batteries to explode Do not expose charger to rain The charger will become hot during use provide adequate air flow aro...

Page 5: ...ng batteries Chargers can ignite flammable materials and vapors Do not use near fuels grain dust solvents or other flammables Do not charge batteries in excessively hot temperatures wait till the cool...

Page 6: ...nance mode assures batteries will remain charged and won t self discharge IMPORTANT Use switch numbers as a guide as some boards may be upside down and reversed When batteries are connected in Paralle...

Page 7: ...eries requiring long finish rates If your performance is poor it could be the batteries are being undercharged Verify with specific gravity readings on wet cells US Battery and Full River are two bran...

Page 8: ...having the same rating Check that there is power at the source If using an extension cord check that it is not damaged When I put a volt meter across the output of the charger there is no power coming...

Page 9: ...it s fuse or branch circuit fuse circuit breaker as soon as it s switched on Charger is shorted Contact factory The charger blows the branch circuit fuse circuit breaker a short while after being swi...

Page 10: ...repaired item will thenbe returned freight prepaid by QuickCharge Thiswarranty isvoid if the charger or component havebeenaltered changed or repaired by anyone notauthorized by QuickCharge or if the c...

Reviews: