Quick Charge QP Operating Instructions Manual Download Page 1

 
 
 
 
 
 
 
 
 
 
 
 

O P E R A T  I N G   I N S  T R U C T I O N S 

                         QP, QPXU Battery Chargers 

For Industrial  Use

:

  Designed for gel, wet cell, AGM,  and Lithium Ion Batteries 

                           (Lithium ion applications 

must b e factory programmed

 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
Quick Charge  Corp. 
800  658-2841 
e-mail 

[email protected]

 

www.quickcharge.com

 

Made  in the U.S.A

 

101712 

Summary of Contents for QP

Page 1: ...Battery Chargers For Industrial Use Designed for gel wet cell AGM and Lithium Ion Batteries Lithium ion applications must be factory programmed Quick Charge Corp 800 658 2841 e mail quickcharge icnet...

Page 2: ......

Page 3: ...AC WIRING Before making AC connections refer to the requirements on the charger ID label If your charger is not equipped with an AC plug for example a 230 volt charger have a qualified electrician ins...

Page 4: ...r from the batteries when the charger is on The resulting arcing could cause the batteries to explode Do not expose charger to rain The charger will become hot during use provide adequate air flow aro...

Page 5: ...ng batteries Chargers can ignite flammable materials and vapors Do not use near fuels grain dust solvents or other flammables Do not charge batteries in excessively hot temperatures wait till the cool...

Page 6: ...nance mode assures batteries will remain charged and won t self discharge IMPORTANT Use switch numbers as a guide as some boards may be upside down and reversed When batteries are connected in Paralle...

Page 7: ...eries requiring long finish rates If your performance is poor it could be the batteries are being undercharged Verify with specific gravity readings on wet cells US Battery and Full River are two bran...

Page 8: ...having the same rating Check that there is power at the source If using an extension cord check that it is not damaged When I put a volt meter across the output of the charger there is no power coming...

Page 9: ...it s fuse or branch circuit fuse circuit breaker as soon as it s switched on Charger is shorted Contact factory The charger blows the branch circuit fuse circuit breaker a short while after being swi...

Page 10: ...repaired item will thenbe returned freight prepaid by QuickCharge Thiswarranty isvoid if the charger or component havebeenaltered changed or repaired by anyone notauthorized by QuickCharge or if the c...

Reviews: