background image

ON / OFF /

CONFIGURE

ENERGY SAVING

(MARCHE / ARRÊT /

ÉCONOMIE D’ÉNERGIE)

Larger
Top Tab
Grande
languette
supérieure

Screen

Grillage

Base Tab
Languette base

Figure 11

Smaller Top Tab / Petite languette supérieure

Screen

Screen

Grillage

Grillage

Figure 12

UP (HAUT)

DOWN (BAS)

1. 

If the screen is not in place, insert the screen into the tab at
the base of the unit (make sure the wider side of the screen is
running side to side inside the unit) 

(Figure 11).

2. 

Slide the screen to the side with the larger top tab making sure
the screen fits behind the tab 

(Figure 11).

3. 

Slide the screen back over towards the smaller top tab making
sure the screen fits behind the tab 

(Figure 12).

4. 

Confirm that the screen is being held in place by both top tabs

(Figure 12).

5. 

Close the access panel and reinstall the screws holding the
access panel in place.

6. 

Restore power and test your installation.

SECTION 9 (

QFDC model)

Setting the Controller

 

The unit mounted controller monitors temperature and humidity
of incoming air and allows the installer to configure optimal
ventilation.

With power to the unit turned on, the initial screen will show “OFF”.

1.  Si le grillage n’est pas en place, insérez le grillage dans la

 

languette située à la base de l’unité (assurez-vous que le côté le plus
large du grillage est latéral à l’intérieur de l’unité) 

(Figure 11).

 

2.  Faites glisser le grillage sur le côté avec la plus grande languette

 

supérieure en vous assurant que le grillage s’adapte derrière la

 

languette 

(Figure 11).

 

3.  Faites glisser le grillage vers la plus petite languette supérieure en

 

vous assurant que le grillage se place derrière la languette 

(Figure 12).

 

4.  Confirmez que le grillage est maintenu en place par les deux

 

languettes supérieures 

(Figure 12).

 

5  Fermez le panneau d’accès et réinstallez les vis qui maintient le

 

panneau d’accès en place.

 

6.  Restaurer l’alimentation et tester votre installation.

 

SECTION 9 (QF

DC modelo) 

Régl age d u  c on t r ôl eu r

 

Le contrôleur monté sur l’unité surveille la température et l’humidité

 

de l’air entrant et permet à l’installateur de configurer une

 

ventilation optimale.

 

Lorsque l’appareil est allumé, l’écran initial affiche « ARRÊT ».

 

Appuyez sur le bouton « MARCHE » pour afficher la température

 

Press the “ON” button to show the current temperature and

et l’humidité actuelles. En appuyant sur le bouton « MARCHE »,

humidity condition. By pressing the “ON” button, the unit will

l’appareil s’allume pour un débit d’air continu en utilisant les

turn on for continuous air flow using the CFM settings from

paramètres CFM de la 

SECTION 5

 

Réglage de la vitesse

.

SECTION 5

 

Setting the Speed

.

MODE D’ÉCONOMIE D’ÉNERGIE

 (QFDC SOLO) 

REMARQUE: 

Cet appareil est équipé d’un mode d’économie d’énergie qui vous permet

 

de configurer les limites supérieure et inférieure de température et d’humidité. En fixant
ces limites, vous contribuerez à empêcher les changements extrêmes de température ou
d’humidité d’entrer dans l’espace de vie.

 

ENERGY SAVING MODE

 (QFDC ONLY) 

NOTE: 

This unit is equipped with an Energy Saving Mode that allows you to configure upper

 

and lower limits for temperature and humidity. By setting these limits, you will help prevent
extreme temperature or humidity changes from entering into the living space.

 

1.  If you have not already pressed the “ON” button in step one of this section, do so now.

 

1.   Si vous n’avez pas encore appuyé sur le bouton « MARCHE » à la première étape de cette

 

section, faites-le maintenant. Appuyez une fois sur le bouton « CONFIGURE » et l’écran

 

affichera « C » et « Unité Temp » sur le côté droit.

 

2.   Appuyez sur le bouton haut ou bas pour afficher la température en degrés Fahrenheit ou Celsius.

3.   Appuyez à nouveau sur le bouton « CONFIGURE » pour régler la température limite supérieure.

 

C’est la température où lorsque l’air extérieur arrive dans la maison, le ventilateur s’arrête et

 

passe en mode d’échantillonnage. Vous verrez « Limite supérieure » et « Température » sur le

 

côté droit. Utilisez les boutons « HAUT » et « BAS » pour ajuster la température.

 

4.   Appuyez à nouveau sur le bouton « CONFIGURE » pour régler la limite supérieure du niveau

 

d’humidité. C’est le niveau d’humidité où, lorsque l’air extérieur arrive dans la maison, le

 

ventilateur s’arrête et passe en mode d’échantillonnage. Vous verrez « Limite supérieure » et «

 

Humidité » sur le côté droit. Utilisez les boutons « HAUT » et « BAS » pour ajuster la température.

 

5.   Appuyez à nouveau sur le bouton « CONFIGURE » pour régler le niveau de température

 

inférieur. C’est la température où lorsque l’air extérieur entrant dans la maison tombe en

 

dessous, le ventilateur s’arrête et passe en mode d’échantillonnage. Vous verrez « Limite

 

inférieure » et « Temperature » sur le côté droit. Utilisez les boutons « HAUT » et « BAS »

 

pour ajuster la température.

 

6.   Appuyez à nouveau sur le bouton « CONFIGURE »  pour régler le niveau d’humidité limite

 

inférieure. C’est le niveau d’humidité qui, lorsque l’air extérieur entrant dans la maison tombe

 

en dessous, le ventilateur s’arrête et passe en mode d’échantillonnage. Vous verrez “Limite

 

inférieure” et “Humidité” sur le côté droit. Utilisez les boutons « HAUT » et « BAS » pour ajuster

 

la température. Si vous réglez ce paramètre sur 0 ou “LO”, le niveau de réglage de l’humidité

 

est annulé. Cela peut être nécessaire dans les zones à très faible humidité du pays.

 

7.   Appuyez sur le bouton « CONFIGURE » jusqu’à ce qu’il revienne à l’écran principal. Vous verrez

 

« MARCHE » dans le coin supérieur gauche de l’écran. À ce stade, l’information a été suvegardée.

 

SECTION 10 (FD

C Modelo) 

Ut i l i sat i on  d u  c on t r ôl eu r

 

1.   

Mode Économie d’énergie:

 Pour passer en mode Économie d’énergie, appuyez sur

 

le bouton « MARCHE / ARRÊT / ÉCONOMIE D’ÉNERGIE » jusqu’à ce que « Économie

 

d’énergie » apparaisse sur le côté gauche de l’écran. Le mode Économie d’énergie active

 

les paramètres configurés dans la 

SECTION 9

 

Mode Économie d’énergie

.

 

2.   Lorsque l’appareil est allumé, l’écran affichera les conditions actuelles (température et

 

niveau d’humidité) ainsi que s’il est en mode Économie d’énergie ou non. D’autres icônes

 

/ informations pouvant figurer à l’écran incluent:

 

L’icône du ventilateur apparaît lorsque le ventilateur est allumé.

 

« HI ° F » apparaît si la température d’entrée est supérieure à 150 ° F.

 

« Lo ° F » apparaît si la température d’entrée est inférieure à 15 ° F.

 

« Lo% » apparaît si l’humidité d’entrée est inférieure à 10%.

 

Press the “CONFIGURE” button once and the display will show a “C” and “Temp Unit” on

 

the right hand side.

 

2.   Press the up or down button to display the temperature in Fahrenheit or Celsius.

 

3.   Press the “CONFIGURE” button again to set the upper limit temperature. This is the

 

temperature that when the outside air coming into the home exceeds, the fan will stop

 

and enter sampling mode. You will see “Upper Limit” and “Temperature” on the right

 

hand side. Use the “UP” and “DOWN” buttons to adjust the temperature.

 

4.   Press the “CONFIGURE” button again to set the upper limit humidity level. This is the

 

humidity level that when the outside air coming into the home exceeds, the fan will stop

 

and enter sampling mode. You will see “Upper Limit” and “Humidity” on the right hand

 

side. Use the “UP” and “DOWN” buttons to adjust the temperature.

 

5.   Press the “CONFIGURE” button again to set the lower temperature level. This is the

 

temperature that when the outside air coming into the home falls below, the fan will stop

 

and enter sampling mode. You will see “Lower Limit” and “Temperature” on the right

 

hand side. Use the “UP” and “DOWN” buttons to adjust the temperature.

 

6.   Press the “CONFIGURE” button again to set the lower limit humidity level. This is the

 

humidity level that when the outside air coming into the home falls below, the fan will

 

stop and enter sampling mode. You will see “Lower Limit” and “Humidity” on the right

 

hand side. Use the “UP” and “DOWN” buttons to adjust the temperature. Setting this to 0

 

or “LO” will override the humidity set level. This may be necessary in very low humidity

 

areas of the country.

 

7.   Press the “CONFIGURE” button until it returns to the main screen. You will see “ON” in

 

the top left corner of the display. At this point, the information has been stored.

 

SECTION 10 (

QFDC Model) 

Usi n g t h e Con t r ol l er

 

1.   

Energy Savings Mode:

 To enter the Energy Savings mode, press the “ON/OFF/ENERGY

 

SAVINGS” Button until “Energy Savings” appears on the left side of the display. Energy

 

Savings mode engages the settings configured in 

SECTION 9

 

Energy Saving Mode

.

 

2.   When the unit is on, the display will show the current conditions (temperature and

 

humidity level) as well as if it is in Energy Savings mode or not. Other icons/information

 

that may be on the display include:

 

Fan icon appears when the fan is on.

 

“HI°

F

” appears if the intake temperature is above 150°F.

 

“Lo°

F

” appears if the intake temperature is below 15°F.

 

“Lo%” appears if the intake humidity is below 10%.

 

3. 

Unité de chauffage optionnelle:

 Une unité de chauffage optionnelle est disponible

3. 

Optional Heater Unit:

 An optional heater unit is available for climates that the air coming

pour les climats où l’air entrant dans l’unité tombe en dessous de 54 ° F. Pour installer

into the unit falls below 54°F. To install the unit, follow the direction that are included

l’unité, suivez les instructions fournies avec cette unité. L’écran affichera une icône de

with that unit. The display will show a thermometer icon with either a “1” or “1 2” when

thermomètre avec un « 1 » ou « 1 2 » lorsque la plage de température est à un niveau

the temperature range is at a level where the heating element would come on if present.

où l’élément chauffant s’allume s’il est présent. Étape 1 - «1» s’allume lorsque la

Stage 1 - “1” turns on when the intake air temperature is between 39°F and 54°F. Stage

température de l’air d’admission se situe entre 39 ° F et 54 ° F. Les étapes 1 et 2 « 1 2 »

1 and 2 “1 2” turn on when the intake air temperature is between 33°F and 39°F.

s’allument lorsque la température de l’air d’admission se situe entre 33 ° F et 39 ° F.

4. 

To restore the factory setting, make sure the unit is in the “OFF” setting. Hold both the

4. 

Pour restaurer le réglage d’usine, assurez-vous que l’appareil est réglé sur « ARRÊT ».

“UP” and “DOWN” buttons for approximately 5 seconds. The “OFF” on the display will

Maintenez les boutons « HAUT » et « BAS » pendant environ 5 secondes. L’indication «

flash to confirm the settings have been restored.

ARRÊT » sur l’affichage clignote pour confirmer que les réglages ont été restaurés.

6727924 Rev. G 5-20

4 of 8

Summary of Contents for QFDC

Page 1: ...requispour labonnecombustionet l vacuationde equipment manufacturer sguidelineandsafetystandardssuchasthosepublishedby gazpar leconduit chemin e provenant d quipement debr lageaucombustible theNationa...

Page 2: ...ECO MMENDEDFO RBEST ATTENTION TO USLESCO NDUITSDO IVENT TRE PERFO RMANCE CO NFO RMESAVECLESCO DESDUBA TIMENTLO C AUXET NA TIO NAUX CAUTION ALLDUCTINGMUSTCO MPL YWITHLO C AL ANDNA TIO NALBUILDINGCO DES...

Page 3: ...optional motorizeddamper canbeconnectedtotheunit Thedamper is U namortisseur motoris optionnel peut treconnect l unit L amortisseur connect viaa24Vtransformer that plugsintothereceptacleintheunit Figu...

Page 4: ...ons H AU T et BAS pour ajuster latemp rature Si vousr glezceparam tresur 0ou LO leniveauder glagedel humidit est annul C elapeut tren cessairedansleszones tr sfaiblehumidit dupays 7 Appuyezsur lebouto...

Page 5: ...seutilisation de shippingchargesfromAir Kingfollowingwarrantyrepairsor replacement r parationfaiteou tent esnonautoris es C ettegarantienecouvrepaslesco tsd exp dition ANYANDALLW ARRANTIES EXPRESSEDO...

Page 6: ...hittinghousing of unit 3b Call your dealer for service Trouble Cause Possible Solution Sugg r e 1 Leventilateur ne fonctionne 1a Param tresdecontr le 1a V rifiezlesparam tresde temp ratureet d humidit...

Page 7: ...ountingBrackets Support demontage 5S1650001 2 1 6 Metal Collar Intake Assembl edecollier enm tal de6 po d admission 5S1650002 3 1 6 Metal Collar O utlet Assembl edecollier enm tal de6 po sortie 5S1650...

Page 8: ...NOTES REMARQUES 6727924 R ev G5 20 8 of 8...

Reviews: