background image

 

QX-4150 

USER MANUAL    

|   

09

QUESTAUDIO.NET

SPECIFICATIONS

MODEL

PER CHANNEL

BRIDGED-MONO MODE

LOAD

8Ohm

4Ohm

70V 

(22Ohm)

100V 

(33Ohm)

8Ohm

4Ohm

70V

100V

Maximum Dynamic Power  

(@1KHz, 1% THD)

4x 200W

4x 275W

NA

NA

2x 550W

2x 550W

2x 550W

2x 550W

Maximum Continuous Power  

(@1kHz, 1% THD)

4x 150W

4x 150W

NA

NA

2x 280W

2x 260W

2x 250W

2x 240W

Features

Wake On Music, Auto-Mute 

(1ms wake-up), Limiting on 

 

High Temperature

Amplifier Protection Systems

Thermal protection, 

 

Over-Current Protection, 

 

DC Protection, HF Protection

Mains Input Voltage Range

85VAC - 265VAC

Standby Power Consumption

3.8W

Muted Power Consumption

9.5W

Idle Power Consumption

16W

Standard Power Consumption 

(Pink Noise@ 1/8th Rated 

Power, 8Ohm)

75W

Output Connector       

2-pin Phoenix (5.08mm pitch) 

with a screw lock

Mains Connector

Standard IEC C14

Dimensions (H x W x D)

44 x 482 x 344 mm 

 

(1.75 x 19 x 13.5")

Weight

5.3kg (11.7 lbs)

Accessories

Mains Cable, Feet, User Manual, 

Phoenix Plugs

Frequency Response

20-20kHz (+/-0.3dB)

Peak Output Current

25A

Dynamic Range

104dB (A-weighted)

Noise Level

-72dBu (A-weighted)

Distortion (1kHz@1W/8Ohm)

0.006%

Distortion (1kHz@50W/8Ohm)

0.006%

Crosstalk (1kHz@1W/8Ohm)

-90dB

Gain

26dB/32dB

Maximum Input Level

+24dBu

Input Type

Analogue Balanced 3-pin 

Phoenix (5.08mm pitch) + 

Optional Expansion Module

Input Sensitivity

+7dBu/+4dBu

Input Impedance

10kOhm

Output Resistance

22.5mOhm/43.6mOhm

Front Controls

Volume Adjust, 80Hz HPF 

Enable, 100Hz LPF Enable, 

Bridged-Mono Enable, Limiter 

Enable, Auto-Standby Enable

Indicators (LEDs)

Blue/Orange

Active/

Standby

Orange

Protection

Green

Signal 

Detection

Orange/Red

Limiter/Clip

Cooling

Fan cooled, temperature 

dependent

* All specifications were measured at 240VAC
** Quest Engineering reserves the right to make changes in 
specifications, or products without prior notice.
*** The figures shown above are ‘real world’, usable specifications and 
are conservative as a result. Quest Engineering does not believe in 
portraying misleading or exaggerated specifications.

Summary of Contents for QX-4150

Page 1: ...QX 4150 USER MANUAL 01 QUESTAUDIO NET QUESTAUDIO NET QX 4150 USERMANUAL ...

Page 2: ... commercial AV or domestic applications the QX range of amplifiers provide superior class D performance with proven reliability without compromise SAFETY PRECAUTIONS Please read the instructions in this section carefully before use Ensure all instructions in this manual are observed as all information contained within is very important It is also highly recommended that this manual is retained for...

Page 3: ...he event of storms and or lightning ensure all devices are disconnected from mains power in order to prevent damage to any of the units in the system When cleaning the unit ensure it has been disconnected from any power source and that only a dry cloth is used Do not use any aerosol or liquid based cleaners Ensure all electronics are electronically grounded earthed to a safety ground terminal in o...

Page 4: ...plifier is clipping HPF Off Amplifier passing full range signal On 80Hz High Pass Filter Active 24dB Oct LPF Off Amplifier passing full range signal On 100Hz Low Pass Filter Active 24dB Oct LIMIT Off Amplifier will not limit On Amplifier will limit to prevent clipping A STBY Off Amplifier will not enter power saving mode On Amplifier will enter sleep mode after 25 minutes of no signal BRIDGED MONO...

Page 5: ...5 QUESTAUDIO NET REAR PANEL CONNECTIONS CH1 Input CH2 Input CH3 Input CH4 Input Phoenix Euroblock CH1 Output CH2 Output CH3 Output CH4 Output Phoenix Euroblock Mains Connection IEC Blank Plate for Expansion Module optional ...

Page 6: ...plifier has a selectable limit option which can be engaged to help avoid clipping and it is recommended that this mode is used if the potential exists for extended periods of overdriving The amplifier has a protection circuit which activates when a fault condition exists The LED will stay illuminated until the fault is resolved The protection circuit activates to help prevent damage to the amplifi...

Page 7: ...led by toggling the under panel A STBY switch from Off to On In this mode if no signal is detected for 25 mins the amplifier will sleep and wake within 660ms of detection of signal Mute mode puts the amp into a light sleep and occurs when the Standby option has been selected and no signal has been detected for 10mins if the amplifier detects signal it will wake within 1ms When no signal has been d...

Page 8: ...ier is to be used in Bridge Mono mode for low impedance speakers or to drive high impedance loads 70 100v the under panel Bridged Mono control switch should be in the On position and input connection wired to input 1 for channels 1 2 and channel 3 for channels 3 4 This can easily be remembered by noting the circle around the and signals on input connectors 1 3 ...

Page 9: ...ssories Mains Cable Feet User Manual Phoenix Plugs Frequency Response 20 20kHz 0 3dB Peak Output Current 25A Dynamic Range 104dB A weighted Noise Level 72dBu A weighted Distortion 1kHz 1W 8Ohm 0 006 Distortion 1kHz 50W 8Ohm 0 006 Crosstalk 1kHz 1W 8Ohm 90dB Gain 26dB 32dB Maximum Input Level 24dBu Input Type Analogue Balanced 3 pin Phoenix 5 08mm pitch Optional Expansion Module Input Sensitivity 7...

Page 10: ...QX 4150 USER MANUAL 10 QUESTAUDIO NET TECHNICAL DRAWINGS QX 4150 345mm Height 1RU 19 ...

Page 11: ...ing Quest Please take the time to complete your product registration Registering your Quest Engineering product will Confirm your warranty Register your product Protect your new product REGISTER ONLINE questaudio net warranty reg For spare parts and service ...

Reviews: