background image

 

QX-4150 

USER MANUAL    

|   

06

QUESTAUDIO.NET

BASIC OPERATION GUIDELINES

Due to the advanced power saving feature of the QX-4150, the amplifier has been designed to power 
from the mains with no additional switch. The amplifier has a removable grille on the front panel. The 
grille is held in place magnetically and can easily be removed without tools to access controls to engage 
a number of modes which are described in the next section. High Pass and Low Pass filters can also be 
activated to provide basic frequency dividing functions, these are most commonly used in a system with 
sub-woofers.

To avoid harm to connected speakers it is important to not clip the amplifier for extended period of times. 
Clipping occurs when the input signal is excessive and overloads the input or output of the amplifier. 
To avoid clipping reduce the level of the input. The amplifier has a selectable limit option which can be 
engaged to help avoid clipping and it is recommended that this mode is used if the potential exists for 
extended periods of overdriving.

The amplifier has a protection circuit which activates when a fault condition exists. The LED will stay 
illuminated until the fault is resolved. The protection circuit activates to help prevent damage to the 
amplifier and connected speakers. Common causes can be shorted wiring or faulty speakers.  If the 
Protect light illuminates disconnect the amp from power and then disconnect the speakers. Reconnect 
the amp to mains and check the status of the protect LED, if the LED has not turned back on then check 
the speakers and cabling for faults.

If the amplifier is to drive high impedance speaker loads (70 or 100v) then Bridge mode must be enabled, 
it is possible to have half the QX-4150 running high impedance loads and the other half running low 
impedance loads, e.g. Ch 1&2 Bridged 70/100v and Ch 3&4 connected to separate 4/8 ohm loads or 
bridged to 4/8 ohm or 70/100v.

Summary of Contents for QX-4150

Page 1: ...QX 4150 USER MANUAL 01 QUESTAUDIO NET QUESTAUDIO NET QX 4150 USERMANUAL ...

Page 2: ... commercial AV or domestic applications the QX range of amplifiers provide superior class D performance with proven reliability without compromise SAFETY PRECAUTIONS Please read the instructions in this section carefully before use Ensure all instructions in this manual are observed as all information contained within is very important It is also highly recommended that this manual is retained for...

Page 3: ...he event of storms and or lightning ensure all devices are disconnected from mains power in order to prevent damage to any of the units in the system When cleaning the unit ensure it has been disconnected from any power source and that only a dry cloth is used Do not use any aerosol or liquid based cleaners Ensure all electronics are electronically grounded earthed to a safety ground terminal in o...

Page 4: ...plifier is clipping HPF Off Amplifier passing full range signal On 80Hz High Pass Filter Active 24dB Oct LPF Off Amplifier passing full range signal On 100Hz Low Pass Filter Active 24dB Oct LIMIT Off Amplifier will not limit On Amplifier will limit to prevent clipping A STBY Off Amplifier will not enter power saving mode On Amplifier will enter sleep mode after 25 minutes of no signal BRIDGED MONO...

Page 5: ...5 QUESTAUDIO NET REAR PANEL CONNECTIONS CH1 Input CH2 Input CH3 Input CH4 Input Phoenix Euroblock CH1 Output CH2 Output CH3 Output CH4 Output Phoenix Euroblock Mains Connection IEC Blank Plate for Expansion Module optional ...

Page 6: ...plifier has a selectable limit option which can be engaged to help avoid clipping and it is recommended that this mode is used if the potential exists for extended periods of overdriving The amplifier has a protection circuit which activates when a fault condition exists The LED will stay illuminated until the fault is resolved The protection circuit activates to help prevent damage to the amplifi...

Page 7: ...led by toggling the under panel A STBY switch from Off to On In this mode if no signal is detected for 25 mins the amplifier will sleep and wake within 660ms of detection of signal Mute mode puts the amp into a light sleep and occurs when the Standby option has been selected and no signal has been detected for 10mins if the amplifier detects signal it will wake within 1ms When no signal has been d...

Page 8: ...ier is to be used in Bridge Mono mode for low impedance speakers or to drive high impedance loads 70 100v the under panel Bridged Mono control switch should be in the On position and input connection wired to input 1 for channels 1 2 and channel 3 for channels 3 4 This can easily be remembered by noting the circle around the and signals on input connectors 1 3 ...

Page 9: ...ssories Mains Cable Feet User Manual Phoenix Plugs Frequency Response 20 20kHz 0 3dB Peak Output Current 25A Dynamic Range 104dB A weighted Noise Level 72dBu A weighted Distortion 1kHz 1W 8Ohm 0 006 Distortion 1kHz 50W 8Ohm 0 006 Crosstalk 1kHz 1W 8Ohm 90dB Gain 26dB 32dB Maximum Input Level 24dBu Input Type Analogue Balanced 3 pin Phoenix 5 08mm pitch Optional Expansion Module Input Sensitivity 7...

Page 10: ...QX 4150 USER MANUAL 10 QUESTAUDIO NET TECHNICAL DRAWINGS QX 4150 345mm Height 1RU 19 ...

Page 11: ...ing Quest Please take the time to complete your product registration Registering your Quest Engineering product will Confirm your warranty Register your product Protect your new product REGISTER ONLINE questaudio net warranty reg For spare parts and service ...