background image

INST

ALLA

TION

Installation Procedure

Mains Power Connection 

Before connecting the amplifier to the mains power, 
make certain that the voltage corresponds with that 
indicated on the rear of the amplifier. A variation of 
10% is acceptable. Refer to safety warnings before 
switching on.

Power Up 

It is standard procedure to power up the amplifiers last 
and shut down first. The QA series amplifiers feature 
turn on delays as the power up diagnostic circuits 
search for faults, so turn on “thump” is avoided. The 
speaker outputs are switched into circuit once checks 
are complete and normal operating voltages are 
present at all stages of the amplifier.

When powering up multiple amplifiers, a staged turn 
on is suggested as the power surge of simultaneously 
switching on multiple amplifiers can exceed the power 
supply capability causing circuit breakers to disengage.

Power Requirements 

The QA Series amplifier is capable of high output 
voltages. When multiple amplifiers will be operating 
simultaneously, make sure the power supply is 
adequate for all amplifiers to draw full power. In this 
case three phase power of sufficient Amperage supply 
capacity will give best results from your amplifiers.

In the case where power is to be supplied from mobile 
generators, It may help to “load the generator” with 
some lighting to create a reserve of power from 
the generator for the amplifiers. Amplifiers do not 
necessarily draw high continuous power as lighting 
will, but have a high demand for dynamic power 
and can draw very high amounts of current for short 
durations. If the power in not available, distortion and 
reduced performance will result.

Rack mount installation 

In permanent installation or mobile rack mounting it 
is recommended to secure the amplifier from both 
front and rear rack mounting facilities. For mobile 
application, this practice is absolutely essential. 
Damage to the amplifier caused by incorrect rack 
mount installation or transit damage is not covered by 
the warrantee.

Installation and electrical interference 

Avoid installing your amplifier near sources of magnetic 
fields such as radio transmitters, welding equipment, 

high current transformers, lighting dimmers or electric 
motors. 

All signal cables should be physically isolated from 
power cables and all audio and amplifier power should 
be supplied via a circuit separate from lighting or stage 
machinery power. Failure to observe this standard 
may generate unwanted noises and hum to the audio 
system.

Connecting cables 

When connecting the audio system, use only balanced 
three conductor signal cable of high quality (screen 
pin1 plus two signal carriers pin2/3). Low cost cable is 
more inclined to pick up radio frequencies and noise 
under certain conditions. For speaker cabinets, always 
use two core copper high current cables of suitable 
length. The thicker the copper core, the less the loss 
on a long speaker line. 
 
It follows to not make speaker cable runs longer than 
necessary. Long runs of thin cable will greatly reduce 
the excellent damping factor of the QA series amplifiers 
causing a loss of “punch” in the bass response. The 
rule of thumb is to use as thick a copper core as is 
practical. It is impossible for a cable to have too much 
copper but too little will cause losses of power and 
reduced damping factor. Unnecessarily long speaker 
cable runs will have the same effect, especially when 
left in a tight coil from a high powered amplifier. 

Bridge mono operation 

In Bridge mono mode, the output of channel A input 
buffer amplifier is connected to both channel A and 
channel B power amplifiers. The signal is routed in a 
manner to bring the channels onto opposite polarity to 

GND

+

+

-

-

1

3

2

INPUT

SHIELD

FROM

PREAMPLIFIER

SHIELD

+

1

3

2

INPUT

FROM

PREAMPLIFIER

+

SHIELD

1. Balanced input connector wiring. 
2. Unalanced input connector wiring.

1. BALANCED

2. UNBALANCED

QA

 SERIES

User Manual

QA

 Series

Power Amplifiers

User Manual

8

Summary of Contents for QA 4004

Page 1: ...QA SERIES QA 1004 QA 2004 QA 3004 QA 4004 POWER AMPLIFIERS user manual...

Page 2: ...ts with solvents or petrochemical based cleaners The power voltages inside this device are high and could cause serious injury or death if touched while the power is connected Do not open the ampli er...

Page 3: ...u for choosing Quest Please take the time to complete your procuct registration card which is included with the packaging Registering your Quest Engineering product will 6 Do not locate ampli ers clos...

Page 4: ...r is then subjected to stress testing before shipping It follows that if your audio installation is completed with the same attention to detail your ampli er will deliver its best results It is recomm...

Page 5: ...orrect wiring instructions A W L A YS SWITCH OFF AMPLIFIER BEFORE OPERATING BRIDGE SWITCH 11 LIMITER Switches between off and on 12 GAIN Input switch to calibrate mixer line level to ampli er input se...

Page 6: ...r band pass type bass boxes The ampli er can be used to power a bass system without the need for an electronic crossover by switching the high pass to 35Hz and the low pass to 80 or 110Hz The input li...

Page 7: ...to control amplifier level Parallel Mono is selected when you have an odd number of speakers such a three Instead of leaving the amplifier in stereo two channel mode and driving two on one side and o...

Page 8: ...y essential Damage to the ampli er caused by incorrect rack mount installation or transit damage is not covered by the warrantee Installation and electrical interference Avoid installing your ampli er...

Page 9: ...e output speaker connector the speaker is now connected across the two channels Power is proportional to the square of the voltage swing so four times the output power is possible The reality is that...

Page 10: ...PIN 1 SIGNAL GROUND LINK A LINK B INPUT A INPUT B Push ToReset 220 240V 10A 50 60Hz OUTPUT A OUTPUT B BRIDGE PIN1 PIN2 PIN3 SIGNAL GND SIGNAL SIGNAL CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN OFF 80H...

Page 11: ...ode switch and gain select switch Two front panels attenuators rear panel mode switch and gain select switch Hi Pass Linkwitz Reily 24 db Octave Off 35 80 Hz Off 35 80 Hz Low Pass Linkwitz Reily 24 db...

Page 12: ...www questaudio net...