Installation

7

Mounting
CAUTION: 
This unit is sealed. The cover is not removable!

Remove the mounting plate from the back of the alarm by

holding the plate and twisting the alarm anti-clockwise in

the direction indicated by the “OFF” arrow on the alarm

cover.

The smoke alarm is suitable for wall mounting.

After selecting the proper smoke alarm location as

described previously, hold the mounting plate against

the selected installation location (wall or ceiling) and

mark the centre of the holes with a pencil. To ensure

aesthetic alignment of the alarm with the hallway, or

wall, the “A” line on the mounting plate should be

parallel with the hallway when ceiling mounted, or

horizontal when wall mounted (Image 3A and 3B). Drill a

hole through the pencil marks and use the enclosed

screws and anchors to secure the mounting plate. Use

a 3/16 inch drill bit for the screw anchor holes.

Press the battery reminder tab down into the battery

compartment while inserting the battery (Image 3E) .

CAUTION: If the battery reminder tab is            not held down in

the battery compartment by the battery, the unit will not

attach to the mounting plate.

Corresponding alignment marks are provided on the

edge of the mounting plate and the alarm. After installing

the mounting plate, place the alarm onto the mounting

plate, making sure the alignment marks are lined up.

Twist the alarm clockwise in the direction indicated by

the “ON” arrow on the alarm cover (Image 3D) until it

locks in place.

0945-7204-00.qxd:_  2009.7.31  4:25 PM  Page

Summary of Contents for Q945

Page 1: ...invisible particles associated with fast flaming fires Home fires develop in different ways and are often unpredictable For maximum protection against fast flaming fires and slow smouldering fires both ionisation and photoelectric alarms should be installed P N 130593 130594 0945 7216 00 e ...

Page 2: ...ndicates the particles of combustion have been detected Removal of the smoke alarm battery will render the smoke alarm inoperative IMPORTANT Read all instructions before installation and keep this manual near the alarm for future reference 1 Manufactured in China for Chubb Fire Security Pty Ltd 33 39 Talavera Road Macquarie Park NSW 2113 Australia Telephone 1800 654 435 Website www quell com au Th...

Page 3: ...outside from waking the sleeper Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on the ceiling in the centre of the room places it closest to all points in the room Ceiling mounting is preferred in ordinary residential construction When mounting an alarm on the ceiling locate it at a minimum of 30 cm 12 in from the side wall Image 2A For mobi...

Page 4: ...IVING ROOM Smoke Alarms for Minimum Protection Ionisation Type Smoke Alarm with Alarm Silencer Hush or Photoelectric Type Smoke Alarms for Additional Protection KITCHEN BEDROOM BEDROOM BEDROOM LIVING ROOM KITCHEN BEDROOM BEDROOM HALL BASEMENT IMAGE 1A IMAGE 1C IMAGE 1B SINGLE FLOOR PLAN MULTIPLE FLOOR PLAN BEDROOM FAMILY ROOM WORKSHOP BASEMENT KITCHEN HALL GARAGE MASTER BEDROOM FIRE EXTINGUISHERS ...

Page 5: ...n the ceiling In such units install the smoke alarm on an inside wall with the top edge of the alarm at a minimum of 10cm 4 and a maximum of 30cm 12 below the ceiling see Image 2A If you are not sure about the insulation in your mobile home or if you notice that the outer walls and ceiling are either hot or cold install the alarm on an inside wall For minimum protection install at least one alarm ...

Page 6: ...not install in areas where the temperature is colder than 0 C or hotter than 40 C such as garages and unfinished attics Do not install in areas where the relative humidity RH is greater than 93 Very humid areas with moisture or steam can cause nuisance alarms Avoid placing smoke alarms in kitchen areas Normal cooking may cause nuisance alarms If a kitchen alarm is desired it should have an alarm s...

Page 7: ...LE PLACEMENT DO NOT INSTALL NOT IN THIS AREA ANYWHERE IN THIS AREA NOT IN THIS AREA ANYWHERE IN THIS AREA PEAK CEILING SLOPED CEILING 500mm 1000mm 1000mm 500mm Smoke alarm should be located between 500mm and 1500mm of the highest point DEAD AIR DEAD AIR DEAD AIR DO NOT INSTALL DO NOT INSTALL 0945 7204 00 qxd _ 2009 7 31 4 25 PM Page ...

Page 8: ...n ceiling mounted or horizontal when wall mounted Image 3A and 3B Drill a hole through the pencil marks and use the enclosed screws and anchors to secure the mounting plate Use a 3 16 inch drill bit for the screw anchor holes Press the battery reminder tab down into the battery compartment while inserting the battery Image 3E CAUTION If the battery reminder tab is not held down in the battery comp...

Page 9: ...Installation 8 IMAGE 3A IMAGE 3C IMAGE 3D A LINE ALIGNMENT MARKS WALL MOUNTING POSITION ROTATE TO MOUNT OR TO REMOVE IMAGE 3B IMAGE 3E BATTERY REMINDER TAB 0945 7204 00 qxd _ 2009 7 31 4 25 PM Page ...

Page 10: ...g plate With the blocks removed the tamper resist feature will be activated when the alarm is installed on the mounting plate The tamper resist tab will have to be released in order to change the battery Using a tool small screwdriver push the tab away from the mounting plate Image 4B and rotate the alarm anti clockwise in the OFF direction After installation test the alarm by depressing and holdi...

Page 11: ...ry or other failure DO NOT use an open flame to test your alarm you could damage the alarm or ignite combustible materials and start a fire CAUTION Due to the loudness 85 decibels of the alarm always stand an arms length away from the unit when testing Test the alarm weekly to ensure proper operation Erratic or low sound coming from your alarm may indicate a defective alarm see Warranty section NO...

Page 12: ...larm senses particles of combustion and goes into alarm constant pulsating sound the red LED will flash once per second The flashing LED beeps will continue until the air is cleared NOTE WEEKLY TESTING IS REQUIRED Alarm Removal To remove the alarm from the mounting plate rotate the alarm anti clockwise in the direction of the OFF arrow on the cover If the tamper resist feature has been used refer ...

Page 13: ...placed Use only the following 9 volt batteries for replacement Carbon Zinc Type Eveready 1222 Gold Peak 1604S Alkaline Type Energizer 522 Duracell MN1604 or MX1604 Gold Peak 1604A Panasonic 6AM6 6AM 6 6AM 6PI 6AM6X or 6LR61 GA Lithium Type Ultralife U9VL J These batteries can be purchased at your local retailer WARNING Use only the batteries specified above Use of different batteries than the reco...

Page 14: ...r entering the unit After cleaning reinstall your alarm and test your alarm by using the Test button If cleaning does not restore the alarm to normal operation the alarm should be replaced Do not paint the unit Paint will seal the vents and interfere with the sensor s ability to detect smoke Never attempt to disassemble the unit or clean inside This action will void your warranty Replacing the Ala...

Page 15: ...lectric alarms should be installed A battery powered alarm must have a battery of the specified type in good condition and installed properly AC powered alarms without battery backup will not operate if the AC power has been cut off such as by an electrical fire or an open fuse Smoke alarms must be tested regularly to make sure the batteries and the alarm circuits are in good operating condition S...

Page 16: ... from each room Second storey windows may need an escape ladder Have a family meeting and discuss your escape plan showing everyone what to do in case of fire Determine a place outside your home where you all can meet if a fire occurs Familiarise everyone with the sound of the smoke alarm and train them to leave your home when they hear it Practice a fire drill at least every six months including ...

Page 17: ...e rush in Stay close to the floor if the air is smoky If possible do not breathe too deeply to avoid smoke inhalation Breathe through a cloth preferably wet if possible Once outside go to your selected meeting place and make sure everyone is there Don t return to your home until the fire officials say that it is all right to do so There are situations where a smoke alarm may not be effective to pr...

Page 18: ...alarms desirable The required number of smoke alarms might not provide reliable early warning protection for those areas separated by a door from the areas protected by the required smoke alarms For this reason it is recommended that the householder consider the use of additional smoke alarms for those areas for increased protection The additional areas include the basement bedrooms dining room fu...

Page 19: ...the goods are offered for sale in New Zealand the benefits to the consumer given by this warranty are in addition to other rights and remedies of the consumer under relevant New Zealand consumer protection laws and other applicable laws relating to the goods Our goods come with guarantees that cannot be excluded under relevant New Zealand consumer protection laws You are entitled to a replacement ...

Page 20: ...z To make a claim If a defect in the product appears within the time frame stated you are entitled to submit a warranty claim by returning your product to the address shown below Please contact Chubb on the telephone numbers provided below Monday to Friday during 9 00AM 5 00PM When returning the product please ensure it is properly packaged so that no damage occurs during transit Any postage and p...