The other way to control the PWRKEY is using a button directly. A TVS component is indispensable to be
placed nearby the button for ESD protection. When pressing the key, electrostatic strike may generate
from finger. A reference circuit is shown in the following figure.
PWRKEY
S1
Close to S1
TVS
Figure 10: Turn on the Module Using Keystroke
The turn on scenarios is illustrated as the following figure.
V
IL
≤ 0.5V
V
IH
≥ 1.3V
VBAT
PWRKEY
(Input)
≥ 100ms
OFF
BOOTING
Module
Status
RUNNING
1
≥ 3.5s
RESET_N
STATUS
>2.3s
Figure 11: Timing of Turning on Module
①
Make sure that VBAT is stable before pulling down PWRKEY pin, the recommended delay time is at
least 30ms. It is not suggested that PWRKEY pin is always pulled down.