GSM/GPRS Module
M85 Hardware Design
M85_Hardware_Design Confidential / Released 73 / 92
1) Power control level PCL 5
2) Power control level PCL 0
5.4. Current Consumption
The values of current consumption are shown as below.
Table 34: The Module Current Consumption
GSM850/EGSM 900
1)
DCS1800/PCS1900
2)
435/400
313/337
mA
mA
DATA mode,
GPRS(2 Rx,3Tx)
GSM850/EGSM 900
1)
DCS1800/PCS1900
2)
605/558
399/460
mA
mA
DATA mode,
GPRS (4 Rx,1Tx)
GSM850/EGSM 900
1)
DCS1800/PCS1900
2)
265/240
200/212
mA
mA
DATA mode,
GPRS (1Rx,4Tx)
GSM850/EGSM 900
1)
DCS1800/PCS1900
2)
615/560
420/470
mA
mA
Peak supply
current (during
transmission
slot)
Maximum power control level on
GSM850 and GSM900.
1.6
1.8
A
Condition
Current Consumption
Voice Call
GSM850
@power level #5 <300mA,Typical 209mA
@power level #12,Typical 96mA
@power level #19,Typical 73mA
GSM900
@power level #5 <300mA,Typical 208mA
@power level #12,Typical 96mA
@power level #19,Typical 73mA
DCS1800
@power level #0 <250mA,Typical 191mA
@power level #7,Typical 93mA
NOTES
Quectel