background image

GV600MA User Manua

l

 

QSZTRACGV600UM0101 

13 

Figure 13.

 

GV600MA LEDs on the Case 

Note: 

1. CELL LED cannot be configured.
2. GPS LED and PWR LED can be configured to turn off by using the configuration tool.
3. Fast flashing: for CELL LED is about 100ms ON/800ms OFF; for GPS LED and PWR LED is about
100ms ON/100ms OFF. 
4. Slow flashing: for CELL LED is about 100ms ON/2000ms OFF; for GPS LED and PWR LED is about
600ms ON/600ms OFF. 

3.10.

 

Temperature Sensor Interface 

Figure 14.

 

Typical Connection with a Temperature Sensor 

Summary of Contents for GV600MA

Page 1: ...GV600 User Manual 1 GV600MA User Manual QSZTRACGV600UM0101 Version 1 01 GPS Tracker ...

Page 2: ...s possession Furthermore system validation of this product designed by Queclink within a larger electronic system remains the responsibility of the customer or the customer s system integrator All specifications supplied herein are subject to change Copyright This document contains proprietary technical information which is the property of Queclink Copying of this document distribution to others o...

Page 3: ...e Color 5 3 Getting Started 6 3 1 Open and Close the Case 6 3 2 Install a SIM Card 7 3 3 Install the Internal Backup Battery 7 3 4 Power Supply Connection 8 3 5 Ignition Detection 8 3 6 Digital Inputs 9 3 7 Analogue Inputs 10 3 8 Digital Outputs 10 3 9 Device Status and LED 12 3 10 Temperature Sensor Interface 13 3 11 Serial Port UART Interface 14 4 Support Peripheral list 15 5 GV600MA Certificati...

Page 4: ...el 4 Table 4 Parts List 4 Table 5 Description of 18 pin Connections 4 Table 6 GV600MA Standard Cable Color Definition 5 Table 7 Electrical Characteristics of Ignition Detection 8 Table 8 Electrical Characteristics of the Digital Inputs 9 Table 9 Electrical Characteristics of Digital Outputs 10 Table 10 Definition of Device Status and LED 12 ...

Page 5: ...Figure 7 Typical Digital Input Connection 9 Figure 8 Typical Analogue Input Connection 10 Figure 9 Digital Output Internal Drive Circuit 10 Figure 10 Typical Connection with a Relay 11 Figure 11 Typical Connection with a LED 11 Figure 12 Typical Connection with a Buzzer 11 Figure 13 Typical Connection with Other Devices 12 Figure 14 GV600MA LEDs on the Case 13 Figure 15 Typical Connection with a T...

Page 6: ...GV600MA User Manual 2 QSZTRACGV600UM104 0 Revision History Version Date Author Description of Change 1 01 Dec 2018 Arry Wang Initial ...

Page 7: ...ver and mobile devices System integration is straightforward as complete documentation is provided for the full featured Track protocol The Track protocol supports a wide variety of reports such as emergency geo fence boundary crossings and external power supply monitoring and scheduled GPS position reports It built in BLE 4 0 communication unit as a Bluetooth device for more devices to interactiv...

Page 8: ...Temperature Sensor Fuel Level Sensor RS232 DUT E 2 3 Interface Definition The GV600MA Tracker has an 18 pin interface connector which contains the connections for power I O TTL etc The sequence and definition of the 18 pin connector are shown in the following figure Figure 1 The 18 pin Connector on the GV600MA Table 5 Description of 18 pin Connections Index Description Comment 1 PWR1 Primary Power...

Page 9: ...50mA max drive current 15 EX_RX UART RXD RS232 16 EX_TX UART TXD RS232 17 RXD UART RXD TTL 18 TXD UART TXD TTL 2 4 GV600MA Standard Cable Color Table 6 GV600MA Standard Cable Color Definition Definition Color Pin No Connector Pin No Color Definition PWR1 Red 1 2 Red Green RWR2 AGNG Black 3 4 Black AGNG IGN White 5 6 Green ADIN1 OUT 3V3 Red White 7 8 Black White GND 1 WIRE Gray 9 10 NC NC OUT IN1 B...

Page 10: ...p case with the bottom case and then tighten the four screws Note Pay attention to the following details to close the case Otherwise the waterproof capability of the device may be deteriorated 1 The positioning poles total 11 on the top cover must be inserted into the holes of the rubber ring as shown below 2 Tighten the screws sufficiently until the rubber ring is squeezed out as shown in the fol...

Page 11: ...the internal battery to the OFF position Insert the SIM card into the holder Take care to align the cut mark and ensure the SIM card is pushed into the SIM holder completely Close the case Figure 2 SIM Card Installation 3 3 Install the Internal Backup Battery GV600MA has an internal backup Li ion battery 5200mAH Figure 3 Backup Battery Installation ...

Page 12: ...cles that operate on 12V or 24V systems without the need of external transformers Figure 4 External Power Supply Connection 3 5 Ignition Detection Table 7 Electrical Characteristics of Ignition Detection Logical Status Electrical Characteristics Active 5 0V to 32V Inactive 0V to 3V or open loop Figure 5 Typical Ignition Detection IGN pin 5 is used for ignition detection It is recommended to connec...

Page 13: ... can be configured to transmit information to the backend server when ignition is on and enter the power saving mode when ignition is off 3 6 Digital Inputs There are four general purpose digital inputs on GV600 They all are negative triggers Table 8 Electrical Characteristics of the Digital Inputs Logical Status Electrical Characteristics Active 0V to 0 8V Inactive Open loop The following picture...

Page 14: ...tion Note Pin 6 is a multifunction pin it can be configured as an analogue input 3 8 Digital Outputs There are four digital outputs on GV600MA All are of open drain type and the maximum drain current is 150 mA Each output has a built in over current PTC resettable fuse Figure 8 Digital Output Internal Drive Circuit Table 9 Electrical Characteristics of Digital Outputs Logical Status Electrical Cha...

Page 15: ...GV600MA User Manual QSZTRACGV600UM0101 11 Figure 9 Typical Connection with a Relay Figure 10 Typical Connection with a LED Figure 11 Typical Connection with a Buzzer ...

Page 16: ...D LED Device Status LED Status CELL Note 1 Device is searching CELL network Fast flashing Note 3 Device has registered to CELL network Slow flashing Note 4 Device goes into sleep mode OFF SIM card needs pin code to unlock ON GPS Note 2 GPS chip is powered off OFF GPS sends no data or data format error occurs Slow flashing GPS chip is searching GPS info Fast flashing GPS chip has gotten GPS info ON...

Page 17: ...d to turn off by using the configuration tool 3 Fast flashing for CELL LED is about 100ms ON 800ms OFF for GPS LED and PWR LED is about 100ms ON 100ms OFF 4 Slow flashing for CELL LED is about 100ms ON 2000ms OFF for GPS LED and PWR LED is about 600ms ON 600ms OFF 3 10 Temperature Sensor Interface Figure 14 Typical Connection with a Temperature Sensor ...

Page 18: ...QSZTRACGV600UM0101 14 3 11 Serial Port UART Interface There are two lines dedicated to the Serial Port UART interface TXD and RXD TXD and RXD are standard TTL signal Figure 15 Typical Connection with USB to TTL Serial Port ...

Page 19: ...re Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and Operated with minimum distance 20cm between the radiator your body 4 1 Bluetooth The device role of Bluetooth could be Master and Slave When the device role is Slave the device will provide below services device information service battery informa...

Reviews: