3.7.
Analogue Inputs
There is one analogue input on GV600MA, and the analogue input voltage range is from 0 to 32V.
The following picture shows the recommended connection.
Figure 7.
Typical Analogue Input Connection
Note:
Pin 6 is a multifunction pin: it can be configured as an analogue input.
3.8.
Digital Outputs
There are four digital outputs on GV600MA. All are of open drain type and the maximum drain
current is 150 mA. Each output has a built-in over current PTC resettable fuse.
Figure 8.
Digital Output Internal Drive Circuit
Table 9.
Electrical Characteristics of Digital Outputs
Logical Status
Electrical Characteristics
Enable
<1.5V @150 mA
Disable
Open drain