MAINTENANCE
To minimize the risk of abnormal heating that can result in system failure, keep the QS-
617/625 uncovered, clean and dust-free. Cleaning the unit should be performed with a
soft, dry cloth.
DO NOT
use solvents or cleaners that may corrode or damage materials
of parts used in the QS-617/625 in any other way.
At least once a month check if Motion Lock Switch is working correctly – turn on the
QS-617/625 (when no one is using the rig) and push the red button. If the machine turns
off and does not react to any signal (turn on simulation or game to check it) then Motion
Lock Switch works properly. If the machine reacts in any different way stop using it and
contact the technical support immediately.
To minimize the risk of QS-617/625 failure, check the condition of the linear actuator’s
rubber seals once a month, and lubricate them externally, if necessary, using a viscous
lubricant spray with dispenser.