Quattroflow 150s Operating And Installation Instruction Download Page 3

 

 

  

 

                                                                                                                     

 

QF150S; edition 2016-05; page 3 of 19   

 

1. General 

 

1.1. Introduction 

 
These operating instructions are valid for the Quattroflow 150S pump. 
 
No liability will be undertaken for any damages caused by non-compliance with the operating 
instructions and service conditions! Original spare parts serve safety purposes. The use of other parts 
may cancel the liability for the consequences and secondary failures resulting thereof.  
 
Manufacturer:  ALMATEC Maschinenbau GmbH  

  

Carl-Friedrich-Gauss-Str. 5 
47475 Kamp-Lintfort, Germany 
Phone: +49 2842 961-0 

  

 

Fax: +49 2842 961-40 
e-mail: [email protected] 

  

 

Internet: www.quattroflow.com 

 
Quattroflow quaternary diaphragm pumps are constructed according to the state of the art and they 
are reliable. Imminent danger by operating error or misuse can lead to damages of properties and/or 
persons. The pumps are to be applied for the intended use and in a safety-related proper condition 
only. 
 

1.2. Storage 

 
In general the Quattroflow pump is delivered operational and packaged. If the unit is not installed right 
away, proper storage conditions are important for a trouble free operation later. The pump has to be 
protected from wetness, coldness, dirtying, UV-radiation and mechanical influences. The following 
storage conditions are recommended: 
- Steady ventilated, dust and vibration free storage room 
- Ambient temperature between 15°C (59°F) and 25°C (77°F) with a relative humidity below 65% 
- Prevention of direct thermal influences (sun, heating) 
 

1.3. Labelling of the pump 

 
The ALMATEC Maschinenbau GmbH is certified as a modern, quality-orientated enterprise according 
to DIN EN ISO 9001:2008 and 14001:2009. Before release for dispatch, any Quattroflow pump has to 
undergo an extended final control. The performance data registered during this are archived in our 
records and can be read back at any time. 
 
As a general rule in the countries of the EU only such machines are allowed to take into operation, 
which are determined to meet the regulations of the EU machinery directive, the harmonized 
standards, European standards and the respective national standards. Hence the operator has to 
verify whether the Quattroflow pump manufactured and delivered properly according to the customers 
order meets the mentioned requirements.  
 
Therefore make sure, before putting the pump into operation, that the pump and the used materials of 
construction are suitable for the provided application and the installation site. 
 
The type label of each Quattroflow pump can be seen on the bottom of the base plate. Besides the 
serial number of the pump head is fixed at the front cover. 

 

 

Summary of Contents for 150s

Page 1: ...trol pa manua are of a ope At d the w Orig and tructi 50S Qu Piston ultiple U anel and hou l carefu an appr rating s ttentio warning inal Ins Insta ions aterna Diaph Use using other v ully befo ropria...

Page 2: ...tructions 8 3 5 Safety hints for the operator 8 3 6 Safety instructions for maintenance inspection and mounting operations 9 3 7 Unauthorized reconstruction and spare part usage 9 3 8 Inadmissible mod...

Page 3: ...nd mechanical influences The following storage conditions are recommended Steady ventilated dust and vibration free storage room Ambient temperature between 15 C 59 F and 25 C 77 F with a relative hum...

Page 4: ...cosmetic research centers or plants Examples Solutions containing proteins albumin IgG Clotting factors monoclonal antibodies enzymes vaccines Solutions of polymers or suspensions silicon latex chroma...

Page 5: ...er Prior to each use we recommend to flush the pump with a proper fluid e g water or buffer Prior to the very first use it might make sense to clean and sanitize the pump chamber A commercial caustic...

Page 6: ...r Panasonic 50 W 230V with integrated frequency inverter Speed control Panasonic Digital Control Panel 2 5 Cleaning CIP Depending on the products in contact with the pump and given requirements the cl...

Page 7: ...max 30 min Follow instructions of the autoclave manufacturer Please make sure that the pump chamber is not placed on the clamp ring during the autoclave process The clamp ring should not be loaded dur...

Page 8: ...strictly the safety guidelines of this manual as well as all national and possible internal regulations e g the handling of chemicals like caustic or acid the handling of biological materials the han...

Page 9: ...art up and check the tightness of the pump o Please respect the relevant additional security advices if the pump has been used for aggressive dangerous or toxic liquids e g suitable protective equipme...

Page 10: ...he right tool for the specific application The user operator is responsible to perform a proper method of testing if the pump should be applied for his specific application The chemical and thermal co...

Page 11: ...led personnel Check the electrical cables before connecting to mains supply During all maintenance work it has to be ensured that no explosive atmosphere can arise Appropriate protection equipment is...

Page 12: ...ecessary to shorten the maintenance intervals for the elastomers significantly In case that the diaphragm broke it needs to be replaced Then it is also recommended to check the ball bearings For corro...

Page 13: ...and the valves can be conducted by the operator The following drawings describe it step by step maintenance kit PSKITQF15MU In case of bursting diaphragms by overpressure we advice also to change the...

Page 14: ...05 page 14 of 19 4 1 3 Assembly of the pump chamber to the ring drive Pay attention to the following torque values Image 2 item 1 Bolts pump chamber 4 Nm 3 lb ft Image 2 item 2 Bolt clamping ring 2 N...

Page 15: ...the bearing unit shaft bearing cap unit kit PSKITWLC155 can be conducted by the operator The following drawings describe it step by step Between both coupling halves has to be a gap of 1 mm 0 039 inc...

Page 16: ...truction in discharge line 9 X Pressure line completely or partly clogged diaphragm maybe broken change diaphragm 10 X The diameter of the pipes in suction or pressure line are too small 11 X Check th...

Page 17: ...p Pump rpm motor rpm The flow rates showing at the chart above were ascertained with new diaphragms and new valves under standard conditions after the final assembly of the pump 0 0 5 1 1 5 2 2 5 3 0...

Page 18: ...face approx cm inch 112 17 112 17 Speed range pump rpm 10 3000 10 3000 Connection specification inlet standard Connector 1 4 TC 1 4 TC Flange diameter mm inch 25 25 Internal diameter mm inch 4 7 4 7 C...

Page 19: ...TDK Lambda power supply Designation n a HWS Analog input optional 0 5V 0 10 V Protection class IP54 IP20 switch board Power supply 230V 50Hz 1P optional 110V 60 Hz 1P 85 265VAC 50 60 Hz 8 2 A Housing...