background image

2

3

To activate sparkling filtered water, touch the 

bottom right control quadrant (glass icon) once.

When the tap releases sparkling water, the bot-

tom right glass icon will illuminate blue, and the 

central screen will display the message ‘spar-

kling.’

The sparkling water function will run for 30 sec-

onds (earlier models have an 8-second time-

out) before automatically switching itself off.

To turn this function off, touch the bottom right 

control quadrant (glass icon) once or touch 

once any of the four control quadrants.

Note:

If the sparkling water is spluttering or is not car-

bonated enough, the system will require adjust-

ment.

If the pump inside the chiller carbonator is ac-

tivating when the tap is not running, please ac-

tivate the sparkling function for one second to 

open the inlet valve which supplies the chiller 

carbonator. Failure to do so could lead to dam-

age.

QUATREAU TOUCH 
SPARKLING WATER

HAND HOT - HOT WATER 
SUPPLY

To activate, touch once 
the bottom left con-
trol quadrant (sink icon) 
once. To turn off, touch 
anywhere on the key-
pad.

Note:

During commissioning, it is 
possible to adjust the tem-
perature to suit personal 
preference. Recommended 
set point is 104°F. To adjust, 
turn the nut on the top of 
the thermal mixing valve in a 
clockwise direction to make the water colder and 
counter-clockwise to make it hotter.

HAND COLD - COLD-WATER SUPPLY

To activate, touch the 
bottom left control quad-
rant (sink icon) twice. To 
turn off, touch anywhere 
on the keypad.

FLOW RATE

Flow rates are set at 
commissioning. To ad-
just flow rate for hand 
hot and cold-water sup-
ply, close the lever ball 
valves feeding the ther-
mal mixing valve.

CAUTION

Maximum operating pressure 30 psi. Do not open 
lever ball valves fully. Excessive pressure and flow 
will cause damage.

The CO2 is controlled 

via the gas canister 

regulator on the front 

of the unit (see dia-

gram). 

Use a large flathead 

screwdriver or a 19mm 

spanner to increase 

the level of carbonation 

in the water. Turn the 

regulator by a half turn 

in a clockwise direction.

To decrease the level of carbonation, turn the 

regulator by a half turn in a counter-clockwise 

direction.

Between adjustments, 

you must run off sev-

eral glasses of spar-

kling water to see the 

effects of the adjust-

ment. If the sparkling 

function is spluttering, 

there is too much gas in 

the water. Reduce the 

setting by one full turn 

and try again.

QUATREAU TOUCH 
HAND HOT AND COLD MAINS WATER

TAP FUNCTIONS:
ADJUSTING THE CARBONATION OF 
THE SPARKLING WATER

CHILLED WATER SEQUENCE

ADJUSTING CARBONATION - HAND HOT & COLD

To activate chilled water,

 touch the top right 

control quadrant (snowflake icon) once.

When the tap releases chilled water, the top 

right snowflake will illuminate white, and the 

central screen will display ‘chilled.’

To turn this function off, touch the top right con-

trol quadrant (snowflake icon) once or touch 

once any of the four control quadrants.

Check the sparkling water 

by tasting it to see if you 

have the proper amount 

of CO2 in the water. If not. 

you will be able to adjust 

using the CO2 regulator.  

QUATREAU TOUCH 

CHILLED WATER 

Thermal Mixing Valve

CO

2