Step 

Description 

Optional 
Press 

Restart

 [Button] 

Restarts the device. After the device as rebooted it will attempt 

to authenticate to the configured network. As long as the 
network is in range the wireless interface will connect. 
If the network is using DHCP then an IP address will be 

assigned to the WLAN interface and IP connectivity is possible 
over the WLAN network. 
If the network is using static IP addresses it will be necessary to 
configure the network interface, see the next step. 

The web interface supports advanced configuration of the device through the additional pages available. The following sections provide 
guidance on how to use these pages for specific configurations. 

 

Table 2 – LED Indicators 

LED 

Color 

Airborne Device State 

POWER

 

 

Adapter is not powered.

 

 

Adapter is powered. 

POST 

 

Adapter is not powered. 

 

Adapter failed Power On Self Test (POST) and is not configured for 
wireless communication. 

 

Adapter passed POST but is not configured for wireless network 

communication. 

 

Adapter passed post and is configured for wireless communication. 

LINK 

 

Adapter is not powered. 

 

(Periodic Blinking) Adapter is searching for a valid network (Access Point) 

that matches device’s configuration. 

 

Adapter has successfully associated with an Access Point. 

COMM 

 

If Power LED is also Off then Adapter is not powered. 
If Power LED is On then: 

 

No TCP session from WLAN or Ethernet interface has been 
established. 

 

A TCP connection to the adapter has been established from the Wireless 

or Ethernet interfaces but no traffic has been detected. 

Get other manuals https://www.bkmanuals.com

Summary of Contents for AirborneDirect ABDG-SE-IN5410

Page 1: ...BDG ET IN50X0 unit with included antenna attached Laptop or desktop system with an Ethernet port 5 36 VDC power for terminal block attachment or an AC power outlet for optional ABDG SE IN5410 IN5420 p...

Page 2: ...DG to an Ethernet port on the laptop or desktop system 4 Apply power to the ABDG SE IN5XXX 5 The unit will boot and display one of the following LED patterns ABDG SE IN5XXX COMM Off LINK Off POST Oran...

Page 3: ...ress Setup If this is the first time you have configured the device the Express Setup page will be displayed This page provides access to the critical configuration items needed to get the ABDG up and...

Page 4: ...cription Navigation Bar Select Configuration You will see a group of fields under the banner of WLAN Parameters Feature Link Select Express Setup This step is optional If this is the first time the de...

Page 5: ...port uses DHCP to assign IP addresses to the wired clients you should select Enabled from the drop down menu If you are using static IP addresses you should select Disabled from the drop down menu Eth...

Page 6: ...how to use these pages for specific configurations Table 2 LED Indicators LED Color Airborne Device State POWER Adapter is not powered Adapter is powered POST Adapter is not powered Adapter failed Po...

Page 7: ...rt 1 DTE Port 2 DTE BAUD 9600 9600 Parity None None Stop Bits 8 8 Data Bits 1 1 Flow Control None None Serial Default Mode Listen Listen Input Buffer Size Bytes 1460 1460 Serial Escape Mode ON ON Seco...

Page 8: ...art Guide Quatech Inc 100 8106 110G 8 4 27 2010 5675 Hudson Industrial Parkway Hudson OH 44236 Tel 330 655 9000 800 553 1170 support quatech com www quatech com 2010 2011 Quatech Inc All rights reserv...

Reviews: