QTrack
™
Antenna System
17
Quasonix, Inc.
Note the Azimuth and Elevation indicators with resolution of 0.01°, indicating the pedestal pointing in El
and AZ frame of reference.
Figure 24: Elevation, Tracking Error, Azimuth Windows
2.
On the Axis Control window, select Manual Mode, as shown in Figure 25, and verify that the Hand Wheel
Position illuminates green for both Elevation and Azimuth Input Controls.
Figure 25: Axis Control Window, Manual Mode Buttons
3.
Operate the ACU hand wheels, and verify the pedestal responds both Elevation and Azimuth commands.