Quasar SSI000 User Manual Download Page 6

User Manual 

 

 

24V OUTPUT – SERIES CONNECTION (voltage increase current remain) 

 

 

24V OUTPUT – SERIES/PARALLEL CONNECTION (both voltage and current increase) 

 

SAFETY INSTRUCTION: 

Please note the following instructions should be carefully followed as any incorrect installation or misuse of 
the inverter may cause harm to user and damage apparatus. 

-

 

Do not connect any other form of input power other than DC power that is within the inverter’s 
acceptance range 

-

 

Ensure the ventilation duct on both front and back panels are clear of blockage when the inverter 
is in use 

-

 

Please use appliance with power rated within the inverter power range. 
Do not attempt to overload the inverter constantly 

-

 

Do not pull on cable when unplugging from the inverter, always grip firmly on the plug 

-

 

To avoid shock hazard, always ensure inverter and DC power supply (if apply) are switched off 
before inserting the AC plug to the inverter 

-

 

Strictly for indoor use only, avoid exposing the unit to any heat source, sunlight, dust, moisture or 
flammable substances 

-

 

It is normal that the inverter will become hot while in use, please avoid touching the unit 

-

 

Do not drop the inverter 

-

 

Do not place any object on the inverter 

-

 

Always connect/set up with cable and accessories supplied and follow the instructions carefully. 
Any use of third party accessories may cause damage and result in injury 

-

 

Do not attempt to service or disassemble the inverter. Any attempt to do so can cause injury to 
user including death from exposure to high voltage. If problems are experienced from the unit 

Summary of Contents for SSI000

Page 1: ...ny damaged caused by misusage of the product WARNING Contain high voltage and high current Do not open or attempt to repair yourself SSI000 001 002 003 004 005 006 007 008 009 010 011 12 and 24V Modif...

Page 2: ...s Unlike pure sine wave inverters modified sine wave inverter is not recommended for powering voltage sensitive or inductive equipment For inductive load such as fluorescent light acoustic equipment a...

Page 3: ...inner temperature less than 30 C the fan will not operate At load between 40 60 the fan will operate at 40 of its maximum speed At load between 60 80 the fan will operate at 60 of its maximum speed A...

Page 4: ...cessories other than the ones provided may cause damage Mercury will not take any responsible for damage caused by use of third party accessories For cable cross section requirement for different mode...

Page 5: ...the start up load is normally twice as much as the rated continuous power of the appliance In some equipment the start up load can be as high as 8 times of its continuous power especially on inductiv...

Page 6: ...onstantly Do not pull on cable when unplugging from the inverter always grip firmly on the plug To avoid shock hazard always ensure inverter and DC power supply if apply are switched off before insert...

Page 7: ...ash Low input power protection warning the input power is below 10 8V 0 2V for 12V input inverter and 21 6V 0 4V for 24V input inverter This indicates the power bank is running low or DC power supply...

Page 8: ...on 24V input inverter 1 Check battery level if it is low please recharge before continuing use 2 On the battery cables used check the cross section area of the conductor is no thinner than recommended...

Page 9: ...months must be shown for warranty to be valid Any unit that has been misused altered or accidentally damaged will not be covered by warranty Mercury will not be responsible for any damage cause as res...

Page 10: ...SURGE POWER 200 of Continuous Power for 2 sec to help starting up AC VOLTAGE 230Vac 10 50Hz SIGNAL WAVE FORM Modified Sine Wave USB 5Vdc 1 0A PROTECTIONS 2 Phases Low Battery Protection warning and c...

Page 11: ...1 pair 4mm2 20A 4 50Ah SSI006UK 12V 1 pair 10mm2 35A 4 160Ah SSI007UK 24V 1 pair 6mm2 20A 4 80Ah SSI008UK 12V 2 pairs 10mm2 35A 6 250Ah SSI009UK 24V 2 pairs 6mm2 20A 6 125Ah SSI010UK 12V 2 pairs 16mm2...

Reviews: