Quasar SSI000 User Manual Download Page 4

User Manual 

 

 

Mounting – The unit should be mounted horizontally; 

we do not recommend mounting the unit vertically

 

Connection: 

-

 

Please ensure the ON/OFF switch on the inverter is in the OFF position and the voltage of power 
source matches the required inverter input voltage, if the power source is from a DC power supply 
please ensure it is switched off also 

-

 

Connect the invert to battery / DC power source. Using provided black cable; connect the 

black negative terminal 

to the 

negative 

output of the power source. Using provided red 

cable; connect the 

red positive terminal 

to the 

positive 

output of the power source. 

-

 

Before connect the inverter to appliances please ensure the appliance power rating is within the 
inverter’s continuous output power. After connected, double check all connections are correct 
before switch on the inverter and appliance. If more than one appliance is being used on the 
same inverter, please ensure appliances are switched on one after the other, after the inverter has 
been switched on. This is to avoid the inverter undergoing any surge current from individual load 
all at once. 

 

Please beware, any use of cables and accessories other than the ones provided may cause damage, 
Mercury will not take any responsible for damage caused by use of third-party accessories. For cable 
cross-section requirement for different models, please refer to accessory appendix at the back of this 
manual. Some models with higher power may have 2 pairs of terminals that require 2 pairs of cable to 
help with the high input current. ALWAYS ensure the correct polarity is connected before start, DO NOT 
reverse input polarity as it will blow up the fuse and may cause permanent damage to the inverter. 

 

Input power specification: 

For an inverter running from a battery, the duration of the appliance is determined by these 3 factors: 

-

 

Voltage of input power 

-

 

Power of the appliance 

-

 

Capacity of the battery 

For example, an appliance of 100W running on a 12V input power inverter will 

require: 100/12 = 8.33 Amp/hour 

A typical 12V car battery has capacity of around 80Ah; to run the above example on this battery we can 
estimate it will be capable of duration of: 

 

80/8.33 = 9.6 hours 

 

In reality, this number will be lower due to the power lost from the efficiency in power conversion (in this 
case over 80% of DC power will be used to convert to AC power) power lost from the input/output cable, 
depreciation of battery capacity on older batteries, and temperature (a cold battery holds less capacity). 

Summary of Contents for SSI000

Page 1: ...ny damaged caused by misusage of the product WARNING Contain high voltage and high current Do not open or attempt to repair yourself SSI000 001 002 003 004 005 006 007 008 009 010 011 12 and 24V Modif...

Page 2: ...s Unlike pure sine wave inverters modified sine wave inverter is not recommended for powering voltage sensitive or inductive equipment For inductive load such as fluorescent light acoustic equipment a...

Page 3: ...inner temperature less than 30 C the fan will not operate At load between 40 60 the fan will operate at 40 of its maximum speed At load between 60 80 the fan will operate at 60 of its maximum speed A...

Page 4: ...cessories other than the ones provided may cause damage Mercury will not take any responsible for damage caused by use of third party accessories For cable cross section requirement for different mode...

Page 5: ...the start up load is normally twice as much as the rated continuous power of the appliance In some equipment the start up load can be as high as 8 times of its continuous power especially on inductiv...

Page 6: ...onstantly Do not pull on cable when unplugging from the inverter always grip firmly on the plug To avoid shock hazard always ensure inverter and DC power supply if apply are switched off before insert...

Page 7: ...ash Low input power protection warning the input power is below 10 8V 0 2V for 12V input inverter and 21 6V 0 4V for 24V input inverter This indicates the power bank is running low or DC power supply...

Page 8: ...on 24V input inverter 1 Check battery level if it is low please recharge before continuing use 2 On the battery cables used check the cross section area of the conductor is no thinner than recommended...

Page 9: ...months must be shown for warranty to be valid Any unit that has been misused altered or accidentally damaged will not be covered by warranty Mercury will not be responsible for any damage cause as res...

Page 10: ...SURGE POWER 200 of Continuous Power for 2 sec to help starting up AC VOLTAGE 230Vac 10 50Hz SIGNAL WAVE FORM Modified Sine Wave USB 5Vdc 1 0A PROTECTIONS 2 Phases Low Battery Protection warning and c...

Page 11: ...1 pair 4mm2 20A 4 50Ah SSI006UK 12V 1 pair 10mm2 35A 4 160Ah SSI007UK 24V 1 pair 6mm2 20A 4 80Ah SSI008UK 12V 2 pairs 10mm2 35A 6 250Ah SSI009UK 24V 2 pairs 6mm2 20A 6 125Ah SSI010UK 12V 2 pairs 16mm2...