background image

SmartCell 212/112 

 
 

4.1.3 Insert 3 dowel pins. 
 
 
 
 
 
 
 
 
 
 
 
4.1.4 Tighten the two upper screws. Leave a gap of 3mm minimum between 
the screw head and the wall. 
 
 
 
 
 
 
 
 
 
 
4.1.5 Mount the SmartCell 212/112 on the 2 screws. 
 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for SmartCell 112

Page 1: ...aims by third parties which may arise through the use of its products Registration and Type Approval Smartcell 212 112 carries CE Certification Australia AS NZS3548 Corporate contacts E mail sales qua...

Page 2: ......

Page 3: ...th 2 channels to any GSM cellular network to create a cellular gateway The SmartCell 112 is a single channel gateway SmartCell 212 112 operates at 900MHz 1800MHz The 212 1900 and 112 1900 models opera...

Page 4: ...SmartCell 212 112 3 Cables Power Cable ISDN Interface Cable SYNC IN Cable Antenna 2 Bags with Screws Dowel pins SmartCell 212 112 unit Drill Template...

Page 5: ...with the standard IGC 950 All connected equipment must comply with the applicable safety standards EN 55022 IEC 1801 2 91 IEC 801 3 IEC 801 4 To avoid injury and prevent equipment damage observe the f...

Page 6: ...otocol Euro ISDN Connector type RJ 45 Data Port Specifications Interface port Connector type RS232 Protocol AT command compatible Dial tone 400 Hz 1 GSM channel specifications Cellular interface Wavec...

Page 7: ...d On the channel is handling a call Slow blinking the SmartCell 112 212 is initialising following power up or is being programmed Fast blinking an error has occurred in the PIN code entry and the outg...

Page 8: ...must be disabled or the default PIN code 1234 must be entered RCPT LVL 2 Reception Level Channel 2 Indicates the reception level of the GSM channel 2 Green High reception Orange Medium reception Red...

Page 9: ...8 4 SmartCell 212 112 Installation 4 1 Installation Instructions 4 1 1 Locate template on the wall and mark screw location 4 1 2 Bore 3 holes...

Page 10: ...SmartCell 212 112 9 4 1 3 Insert 3 dowel pins 4 1 4 Tighten the two upper screws Leave a gap of 3mm minimum between the screw head and the wall 4 1 5 Mount the SmartCell 212 112 on the 2 screws...

Page 11: ...10 4 1 6 Tighten the lower screw 4 1 7 Connect cables Power cable NT cable SYNC IN cable only if necessary...

Page 12: ...SmartCell 212 112 11 4 1 8 Connect antennas Antenna x2 Bracket x2...

Page 13: ...ce point to point with TEI 0 Required 2 On LCR Least Cost Routing enabled systems set the CLI programmed to identify cellular prefixes Optional SmartCell 212 112 becomes transparent to internal caller...

Page 14: ...ote If the PABX will not accept the 212 112 as a sync source use the configuration described in paragraph 4 4 3 Note ISDN Ready LED will be ON 4 4 2 Partial TE mode In this mode the 212 112 is used as...

Page 15: ...over a second cable a straight RJ 45 cable provided with 212 112 This cable connects to any NT port of the PABX without interrupting the traffic If more than one 212 112 need to be connected to the P...

Page 16: ...ialisation Once the SIM cards have been registered and are operational the STATUS LEDs will stop blinking 4 5 3 Verify that the RCPT LVL LED is green indicating high reception level To improve the rec...

Reviews: