Safety Considerations 

General 

This product and related documentation must be reviewed for familiarisation before operation. If 
the equipment is used in a manner not specified by the manufacturer, the protection provided by the 
instrument may be impaired. 

Before Applying Power 

Verify that the product is set to match the available line voltage and the correct fuse is installed. 

Before Cleaning 

Disconnect the product from operating power before cleaning. 

WARNING  

Bodily injury or death may result from failure to heed a warning. Do not proceed beyond a warning 
until the indicated conditions are fully understood and met. 

 

CAUTION 

Damage to equipment, or incorrect measurement data, may result from failure to heed a caution. Do 
not proceed beyond a caution until the indicated conditions are fully understood and met. 

This equipment must be earthed 

An uninterruptible safety earth ground must be maintained from the mains power source to the 
product’s ground circuitry. 

WARNING 

When measuring power line signals, be extremely careful and use a step down isolation transformer 
whose output is compatible with the input measurement capabilities of this product. The product’s 
front and rear panels are typically at earth ground. Thus, never try to measure AC power line 
signals without an isolation transformer. 

 

WARNING 

Instructions for adjustments when covers are removed and for servicing are for use by service-
trained personnel only. To avoid dangerous electrical shock, do not perform such adjustments or 
servicing unless qualified to do so. 

 

WARNING 

Any interruption of the protective grounding conductor (inside or outside the instrument) or 
disconnecting of the protective earth terminal will cause a potential shock hazard that could result 
in personal injury. Grounding one conductor of a two conductor out-let is not sufficient protection. 

Whenever it is likely that the protection has been impaired, the instrument must be made 
inoperative and be secured against any unintended operation. 

If the instrument is to be energised via an autotransformer (for voltage reduction) make sure the 
common terminal is connected to the earthed pole terminal (neutral) of the power source. 

Instructions for adjustments while the covers are removed and for servicing are for use by service-
trained personnel only. To avoid dangerous electrical shock, do not perform such adjustments or 
servicing unless qualified to do so. 

Summary of Contents for A5-32

Page 1: ...l 29 April 2002 Page 1 of 10 MODEL A5 32 32 Way Distribution Amplifier USER S HANDBOOK Quartzlock UK Ltd Gothic Plymouth Road Totnes Devon TQ9 5LH England Tel 44 0 1803 862062 Fax 44 0 1803 867962 Web...

Page 2: ...requency and Power Characteristics 4 Environmental Conditions 4 Replaceable Fusing Characteristics 4 Cleaning Instructions 4 Distribution Amplifier A5 12 5 Operating Procedure 5 Circuit Descriptions 6...

Page 3: ...transformer whose output is compatible with the input measurement capabilities of this product The product s front and rear panels are typically at earth ground Thus never try to measure AC power lin...

Page 4: ...t 10 C to 55 C 65 to 65 op Storage 40 C to 85 C Magnetic Field Sensitivity 2x10 11 Gauss Atmospheric Pressure 60m to 4000m 1x10 13 mbar Replaceable Fusing Characteristics 800mA time lag HBC Cleaning I...

Page 5: ...lled the output amplifiers in the following description A modified version of the output amplifier with a gain control called the input amplifier drives a twelve way passive power splitter This divide...

Page 6: ...of 13 dBm the second harmonic distortion is less than 60 dBc due to the differential design Third harmonic distortion is less than 40 dBc The bandwidth is 1 dB from 2 MHz to 100 MHz The gain falls by...

Page 7: ...analyser to measure the harmonic distortion and verify against the specifications Repeat for other outputs if desired Take care that the spectrum analyser is not generating harmonics so as to affect...

Page 8: ...ser to any input and search for discrete spurii Calculate their level in dBc related to the 13 dBm nominal output Measure the wideband noise using a preamplifier if necessary to improve the spectrum a...

Page 9: ...at nominal output 10 MHz Source harmonics less than 60dBc a Second harmonic 50dBc b Third harmonic 40dBc 7 Isolation a Output to output 90dB adjacent outputs at 10 MHz 70dB adjacent outputs at 100 MHz...

Page 10: ...Model A5 32 Operation And Service Manual A5 32 Manual 29 April 2002 Page 10 of 10 Appendix...

Reviews: