CONFIGURING PASSIVE PANELS
CP-1601A-P REMOTE & CP-1601A-LP LOCAL
There are two jumper links in this control panel to set up Lock and Enable modes.
Unscrew the front panel catches. The links are to be found on the right-hand side of the
PCB upon which the buttons are mounted. Set the two links to the following positions as
shown in the diagram below:
Mode
Links
Lock
or
Destination Toggle
Set to outer positions (away from each other)
Enable
Set to inner positions (close to each other)
The diagram shows the links in the
Lock
or
Destination Toggle
Mode
A
B
A
B
Figure 8: Setting Local Panel Mode
CP-1600A-LP
There is nothing to set on this panel since its operation is determined by the
configuration stored in the
Advanced Controller
module.