background image

 

Version: 1.64                               Edited: 29 Sept 2003                      Manual - 06 

 

(((((<<<<<<Q>> 

 

Q1601 

Q1602 

Monitoring Router 

System Manual

 

Summary of Contents for Q1601

Page 1: ...Version 1 64 Edited 29 Sept 2003 Manual 06 Q Q1601 Q1602 Monitoring Router System Manual...

Page 2: ...pport Telephone 44 0 118 935 0203 E mail support quartzuk com Emergency Technical Support Mobile 44 0 7714 102 629 Copyright Quartz Electronics Ltd 2003 MADE IN ENGLAND All rights reserved No part of...

Page 3: ...parate branch circuits employing separate service grounds NEVER use flammable or combustible chemicals for cleaning components NEVER operate this product with any covers removed NEVER wet the inside o...

Page 4: ...ideo Inputs and Outputs 12 Video Sync 12 Audio Inputs and Outputs 12 Remote Control Passive Panels 13 Remote Control using Q link 14 RS232 422 Serial Port 14 Cascade Mode 16 Power 18 Setting the Power...

Page 5: ...be connected to the router via the Q Link Another major benefit of the Advanced Controller is that several routers can be combined to appear and operate like a single router with a large number of in...

Page 6: ...d the insertion gain so accurately maintained that no adjustment is required A jumper link for each output is provided to correct the gain when driving into 600 loads If it is necessary to drive unbal...

Page 7: ...e router where if accepted it is latched to a low state near 0V so that when the button is released the LED stays lit A series of jumper switches can be set up to determine how the unit operates Refer...

Page 8: ...ers when equipped with the Advanced Controller and the standard remote panels have a single Q Link BNC connector so a T piece is used to tap off the Q link signal into the units In this way a unit can...

Page 9: ...f the Q Link control panels and their operation REMOTE CONTROL PANELS If the standard controller is fitted then the standard passive panel available with this product is the CP 1601A P This is functio...

Page 10: ...oss to 5 5 MHz 40dB VIDEO OUTPUTS Impedance 75 Return Loss to 5 5 MHz 40dB dc on output 50mV SIGNAL PATH Insertion gain 0 1dB HF response 0 2dB to 5 5MHz 3dB to 100MHz Diff Gain and Phase 0 15 0 15 o...

Page 11: ...power cords supplied are suitable for your country Note that some remote panels are mains powered and must be set to the correct mains line voltage PHYSICAL INSTALLATION REMOTE PANELS The passive rem...

Page 12: ...put 1 and J1 for the single feed from Output 2 VIDEO SYNC Analogue video routers take their switching reference signal from Input 1 Serial Video routers have a separate terminating Sync input J2 that...

Page 13: ...ard passive remote panel CP 1601A P is connected to the router using D25 panels The pin connections are as follows Pin Signal Pin Signal 1 Input 1 14 Input 14 2 Input 2 15 Input 15 3 Input 3 16 Input...

Page 14: ...circumstances cause data errors The system can support up to 32 devices Each unit being connected to the Q link has its own address switch which is set up as part of the system configuration RS232 42...

Page 15: ...h a D Type 9 way connector and the router 1 2 6 7 3 8 4 9 5 TXD RXD GND 2 3 5 1 2 6 7 3 8 4 9 5 Cable 9 way to 9 way RS 232 1 2 6 7 3 8 4 9 5 RXD TXD GND 7 3 6 1 2 6 7 3 8 4 9 5 Computer D 9 Plug D 9...

Page 16: ...outers The outputs of the three upstream routers are cascaded into the downstream router equipped with an Advanced Controller module which acts as a master controller for the system Q1601 OUT J1 Q1601...

Page 17: ...is daisy chained to the upstream routers When commands are received from the control panels they are processed in the Advanced Controller in the downstream router It then sends commands to its own cro...

Page 18: ...o service the unit SETTING THE POWER LINE VOLTAGE On units with no voltage selector the PSU is auto ranging and no adjustments are required SETTING THE Q1602E PSU LINK On Q1602E models the internal PS...

Page 19: ...003 fitted SW1 4 Panel function for CP 1601A P or CP 1601A LP SW1 5 Up Standard Down Advanced SW1 6 Sync Mode SD Routers Up Sync from Slave Down from Master HD Routers Up Tri level sync Down 525 625 s...

Page 20: ...n SW1 8 Frame mode Up Field mode Down Analogue Video Router The Sync signal is derived from Input 1 so it is important that a valid signal is provided at this input otherwise video switching will not...

Page 21: ...in the table below Note that the functions of the jumper links are different if the Advanced Controller is fitted Mode LK 5 LK 6 LK 7 17 button panels CP 1601A L P or custom panels 16x1 Lock Enable A...

Page 22: ...ystem Manual 22 V1 64 Main Board LK8 LK9 B A LK7 LK6 LK5 See Text Figure 6 Stand alone Mode Main Board Main Board Master Slave LK8 LK9 B A LK7 LK6 LK5 See Text LK8 LK9 B A LK7 LK6 LK5 See Text Figure...

Page 23: ...ches are different if the Advanced Controller is fitted Mode SW1 2 SW1 3 SW1 4 17 button panels CP 1601A L P or custom panels 16x1 Lock Enable Up Up Up 16x2 Destination Toggle Down Up Up 8x2 Lock Enab...

Page 24: ...Master mode Standard control DIP Switch SW1 Figure 7 Stand alone Mode Main Board Main Board Master Slave Panel 1 2 3 4 Up 5 6 7 8 Up Sync Master mode Standard control DIP Switch SW1 Panel 1 2 3 4 Dn...

Page 25: ...2 routers are used together for instance when the video and two levels of audio are provided by one router and a further two levels of audio by another router In this application one router is set to...

Page 26: ...l 26 V1 64 Main Board FU 0003 Main Board Master Slave LK8 LK9 B A LK7 LK8 LK9 B A LK7 Figure 10 Stack Mode Main Board FU 0003 Main Board Master Slave LK8 LK9 B A LK7 LK8 LK9 B A LK7 LK10 SL M LK10 SL...

Page 27: ...64 27 Analog Video Router The position of the jumper links is shown in the diagram below FRAME FIELD LK10 VS LK1 FLD MS 525 625 SLAVE MASTER LK2 A0 A2 A1 RD WR LK7 LK6 LK5 LK4 LK3 LK8LK9 OPEN SET Fig...

Page 28: ...ether for instance when the video and two levels of audio are provided by one router and a further two levels of audio by another router In this application one router is set to be a master and the ot...

Page 29: ...k Advanced DIP Switch SW1 Up Not used Up Figure 14 Stack Mode Main Board FU 0003 Main Board Master Slave 1 2 3 4 Up 5 6 7 8 Dn Sync Master mode Cascade Advanced DIP Switch SW1 1 2 3 4 Dn 5 6 7 8 Dn Sy...

Page 30: ...m One frame must be set as master and all the others as slaves The master holds the configuration of the system that determines how the system operates and also contains the non volatile RAM that stor...

Page 31: ...e buttons are mounted Set the two links to the following positions as shown in the diagram below Mode Links Lock or Destination Toggle Set to outer positions away from each other Enable Set to inner p...

Page 32: ...t the selection If the destination toggle mode is active then when the LED is off routes are selected on Destination 1 and if the LED is on then routes are selected to Destination 2 Alternate key pres...

Page 33: ...ration Alternatively the default input can be set permanently to any input other than Input 1 by wiring the relevant input pin in the remote CONTROL connector to 0V If joystick override is needed with...