Torridon HS Lite Drive Control Module - Technical Manual
Revision 1.0
©Quarch Technology
Page 21 of 28
SOURce:[1-6|ALL]:DELAY [#ms]
SOURce:[1-6|ALL]:DELAY?
Sets the initial delay of a source in mS. The delay is entered as a decimal number with no
units. E.g. “Source:1:delay 300”.
SOURce:[1-6|ALL]:STATE [ON|OFF]
SOURce:[1-6|ALL]:STATE?
Sets or returns the enable state of the source. Any signals assigned to a disabled (off)
source will immediately be disconnected and vice versa. If a source state is changed, all
signals assigned to it will change at exactly the same time (if a change is required). NOTE:
If the ‘ALL’ selector is used, all 6 sources will be affected BUT there will be a very small
delay between the change of each source. If timing is critical, assign all signals you want
to change to the SAME source.
SIGnal:[SIG_NAME|ALL]:SETup [#num]
SIGnal:[SIG_NAME|ALL]:SOURce [#num]
Sets a given signal to a numbered timing source (0-8). SIGNAL_NAME is one of the
following signals that can be switched by the cable pull module:
12V_POWER
12V_CHARGE
5V_POWER
5V_CHARGE
3V3_POWER
3V3_CHARGE
SPECIAL1
(see drive presence detection support)
Signal groups are used to alter the state of multiple Signals as the same time. Only
commands that alter a setting can use signal groups. Commands that return a setting
value do not support signal groups as there is no single value to return.
ALL
(Affects all signals)
PRIMARY
(Affect all signals relating to the SATA or primary SAS port)
SECONDARY
(Affect all signals relating to the secondary SAS port)
SIGnal:[SIG_NAME]:SOURce?
Returns the source number that the signal is assigned to.
RUN:POWer [UP|DOWN]
Initiates a plug or pull operation (legacy name used to preserve compatibility between
Torridon modules). This is done by changing the HOT_SWAP bit, register 0x00 bit 0. This