4
Operating Conditions
This softening system will operate at maximum efficiency under the following conditions:
Operating Conditions
Working conditions
Working pressure
21 psi to 120 psi
Water temperature
40°F - 120°F (5° C - 50°C)
Working Environment
Environment temperature
40°F - 120°F (5°C - 50°C)
Relative humidity
≤95% when temperature is 25C/77°F
Power source
AC100~240V/50~60Hz
Inlet Water Quality
Water turbidity
Down-flow Regeneration <5FTU
Chlorine
<0.1ppm
Iron2
<0.3ppm
• All plumbing and electrical work should be performed by an accredited professional to ensure all local, munici-
pal, and state codes are met.
• Do not use the water softener with water that is unsafe or of unknown quality.
• Do not use the brine tube, injector body, or other connectors on the valve as a handle to carry the system.
•
Ensure there is salt in the brine tank at all times when in use for softening. The brine tank should contain clean
water softening salt only, at least 99.5% pure. Do not use small grain salt.
•
When there is moderate to high turbidity, a filter should be installed before the softening system on the inlet
side.
• If the water pressure exceeds 80 psi, it is recommended to install a pressure valve. If the water pressure is under
20 psi, a boost pump must be installed before the water inlet.