Configuration
Description
Highest availability
campus configuration
(recommended)
This configuration has the greatest redundancy. It is the most stable of the
three configurations.
•
Two Fibre Channel switches (for a total of four) at both the primary
site and the secondary site provide for complete failover and
redundancy in the Fibre Channel switches and fabrics, in addition to
all storage array components and hosts.
•
A single point of failure does not exist in this configuration, and it is
the recommended configuration.
See
Highest availability campus configuration recommended
on page
112.
Campus configuration
The campus configuration is a lower-cost configuration than the highest
availability campus configuration. Only one Fibre Channel switch at the
primary site and one at the secondary site exist, for a total of two
switches. This configuration essentially allows the minimum required
components to successfully operate between two sites.
•
The number of Fibre Channel switches is reduced from four to two
and the number of fabrics from two to one.
•
This configuration is redundant for host bus adapters, controllers, and
Synchronous Mirroring ports, but it has a single point of failure for
switches and fabric.
•
A switch failure does not usually result in a loss of data, but it does
affect data synchronization until the error is corrected. Therefore, the
highest availability campus configuration is the recommended
configuration, because data synchronization can continue for any
single switch failure.
See
on page 118.
Intra-site
configuration
The intra-site configuration is the lowest-cost configuration of all three
configurations. It is used in environments where a long-distance fabric is
not required because of the close proximity of the hosts and storage
arrays.
•
Because the intra-site configuration only has two switches, it is
similar to the campus configuration. However, multiple-switch fabrics
do not exist in this configuration.
•
The configuration is redundant for host bus adapters, controllers,
Synchronous Mirroring ports, and switches but is a single point of
failure for the site because all of the equipment can be destroyed by
the same disaster.
•
The highest availability campus configuration is the recommended
configuration, because it is fully redundant, which makes disaster
recovery easier.
See
on page 123.
Highest availability campus configuration recommended
Note:
The highest availability campus configuration is the recommended Fibre Channel
configuration for the Synchronous Mirroring feature or the Asynchronous Mirroring feature.
112 |
Summary of Contents for StorNext QD7000
Page 1: ...Hardware Cabling Guide StorNext QD7000 Firmware 8 40 xx xx 6 68683 01 Rev A...
Page 7: ...Preface Hardware Cabling Guide vii...
Page 10: ...E Series Hardware Cabling Guide December 2017 215 11792_B0 doccomments netapp com...
Page 11: ......
Page 90: ...One E5660 controller drive tray and one DE6600 drive tray Drive shelf or drive tray cabling 81...
Page 106: ...One E2760 controller drive tray and one drive tray Drive shelf or drive tray cabling 97...