background image

 3

7. Do you have power applied?

No – Go to step 

9.

Yes – Go to step 

8.

SMcli <

ctrl_IP1

> -c “Set tray [

trayID

] powerCanister[top|bottom] service 

Allowed Indicator=on;”

[trayID]

 is the identifier of the drive tray that contains the power canister that you want to replace. Drive tray ID 

values are 0 to 99. Be sure to type the square brackets around the identifier.

[top|bottom]

 is the identifier of the power canister that you want to replace. Power canister values are either 

top or bottom. Be sure to type the square brackets around the value.

This command turns on the blue Power Service Action Allowed LED and prevents the controller from accessing the 

drive tray (

Figure 2

).

ATTENTION  Possible loss of power

 – To avoid taking the wrong power canister offline and causing the drive tray to lose 

all power, contact your Technical Support representative before performing step 

8.

8. Turn off the Power switch on the power canister that has failed (

Figure 3

). 

Figure 3  Power Switch on the DE6600 Drive Tray

1.

Power Switch

9. Unplug the power cord from the failed power canister. 
10. Remove the power canister from the drive tray (

Figure 4

) by pressing the orange tab toward the black tab, moving the 

power canister latches to the outside, and then pulling the power canister toward you. 
While removing the power canister, you might notice an increase in fan speed. The fan speed returns to normal after 

you have replaced the power canister.

Figure 4  Removing and Replacing a Power Canister

1.

Power Canister Latches

Summary of Contents for StorNext QD7000

Page 1: ...Replacing a Power Supply Unit PSU StorNext QD6000 QD7000 Expansion Unit 6 68486 01 Rev A 6 68486 01 Rev A...

Page 2: ...nit PSU 6 68486 01 Rev A July 2016 Product of USA 2016 All rights reserved Quantum the Quantum logo DXi Scalar and StorNext are registered trademarks of Quantum Corporation and its affiliates in the U...

Page 3: ...ion Intended audience Prerequisites NetApp to Quantum Naming Decoder Intended audience This guide is intended for storage customers and technicians Prerequisites Prerequisites for installing and using...

Page 4: ...dules ESMs E5600 Code Name Titan RAID controller Four 16Gb s FC SFP host ports E5500 Code Name Soyuz RAID controller Four 16Gb s FC SFP host ports E5400 Code Name Pikes Peak RAID controller Four 8Gb s...

Page 5: ...r your particular hardware configuration If you are performing a hardware reconfiguration make sure you have the correct replacement power canister to support the particular controller tray or control...

Page 6: ...storage array 2 Did the Recovery Guru direct you to replace a failed power canister Yes Go to step 3 No Run the Recovery Guru to identify the failed component and then go to step 3 3 Put on antistatic...

Page 7: ...ve tray Figure 2 ATTENTION Possible loss of power To avoid taking the wrong power canister offline and causing thedrive tray to lose all power contact your Technical Support representative before perf...

Page 8: ...blem Yes Go to step 17 No If the problem has not been resolved contact your Technical Support representative 17 Check the status of all of the trays in the storage array 18 Does any component have a N...

Reviews: