background image

iv

Replacing a

n

 

ESM

NetApp to Quantum Naming Decoder

Use 

Table 1

 to correlate the NetApp product nomenclature to the equivalent Quantum-storage 

naming conventions. 

Table 1

Product Nomenclature

E-Series NetApp Product

Quantum-Storage

Description

Controller-Drive Tray

Base System

Quantum uses Base System when referring to a 
drive tray with the RAID controllers.

Drive Tray

Expansion Unit

Quantum uses Expansion Unit when referring 
to a drive tray with the environmental services 
modules (ESMs).

E5600 (Code Name: Titan)

RAID controller

Four 16Gb/s FC SFP+ host ports

E5500 (Code Name: Soyuz)

RAID controller

Four 16Gb/s FC SFP+ host ports

E5400 (Code Name: Pikes Peak)

RAID controller

Four 8Gb/s FC SFP+ host ports

DE6600 (Code Name: Wembley)

4U 60-drive enclosure

60 3.5 inch disk drives

E5560 or E5660
(DE6600 4U drive enclosure with 
E5500 or E5600 RAID controllers)

Quantum StorNext 
QD7000

E5460
(DE6600 4U drive enclosure with 
E5400 RAID controllers)

Quantum StorNext 

QD6000

E5424
(DE5600 24-drive 2U drive 

enclosure (Code Name: Camden) 
with E5400 RAID controllers)

Quantum StorNext 
QS2400

E5412
(DE1600 12-drive 2U drive 
enclosure (Code Name: Ebbets) 
with E5400 RAID controllers)

Quantum StorNext 
QS1200

Summary of Contents for StorNext QD6000

Page 1: ...Replacing an ESM StorNext QD6000 QD7000 Expansion Unit 6 68481 01 Rev A 6 68481 01 Rev A...

Page 2: ...1 Rev A July 2016 Product of USA 2016 All rights reserved Quantum the Quantum logo DXi Scalar and StorNext are registered trademarks of Quantum Corporation and its affiliates in the United States and...

Page 3: ...ion Intended audience Prerequisites NetApp to Quantum Naming Decoder Intended audience This guide is intended for storage customers and technicians Prerequisites Prerequisites for installing and using...

Page 4: ...Ms E5600 Code Name Titan RAID controller Four 16Gb s FC SFP host ports E5500 Code Name Soyuz RAID controller Four 16Gb s FC SFP host ports E5400 Code Name Pikes Peak RAID controller Four 8Gb s FC SFP...

Page 5: ...c protection when handling tray components 1 Gather support data about your storage array by using one of these methods Use the storage management software to collect and save a support bundle of your...

Page 6: ...nect the cables correctly on the replacement ESM canister ATTENTION Possible loss of hardware To avoid taking the wrong ESM canister offline contact your Technical Support representative before perfor...

Page 7: ...he new ESM canister Figure 1on page 2 13 Based on the LED status perform one of these actions The ESM Power LED is on and the ESM Service Action Required LED is off Go to step 15 The ESM Power LED is...

Page 8: ...r storage array From the Array Management Window toolbar select Monitor Health Collect Support Data Then name and specify a location on your system where you want to store the support bundle Use the C...

Reviews: