Compatibility Matrix

Use the following tables for system compatibility. Tests have shown that the components listed below 
interoperate effectively when properly configured. Visit 

www.adic.com

 for the most current version of this 

matrix. 

Known Issues

Advisements pertaining to the latest release of SNC 450x Firmware v. 2.16 are as follows.

Table 1

Compatibility Matrix 

Configuration

Tape Library

Host 

Server

ISV Application

GbE HBA

Model

Tape 

Drives

Platform

Make/Model

1

,

2

1.  CA ARCserve Version 9.01 requires patches through QO51045. 
2. Veritas Backup Exec Version 9.1, and patches 267180, 267250, 267682, 265501. Veritas recommends patch 268600 if 

Intelligent Disaster Recovery (IDR) is used.

Make

Model

3

,

4

3.  Use the following code levels: HBA driver, 1.20.0.39; HBA Firmware, 1.20.41; HBA BIOS,1.2.40.
4.  A host that uses this HBA with Veritas Backup Exec must first be attached to a Gigabit Ethernet switch before being connected 

to the SNC 450x. Otherwise, the software erroneously recognizes the media changer as offline. 

SNC 4501

Scalar 24

SCSI LTO-2

Win2003

Win2000

CA ARCserve

 

9.01 or 11.1

 

Veritas Backup Exec

TM

 

BakBone Netvault 7.1

 

Commvault Galaxy 5.0

 

Legato Networker 7.1.2

1 Gb

 

Adaptec 7211C

SNC 4501

Scalar 24

SDLT-320

Win2003

Win2000

CA ARCserve 11.1

1 Gb

 

Adaptec 7211C

SNC 4500

Scalar 100

SCSI LTO-2

Win2003

Win2000

CA ARCserve

 

9.01 or 11.1

 

Veritas Backup Exec

 

BakBone Netvault 7.1

 

Commvault Galaxy 5.0

 

Legato Networker 7.1.2

1Gb

 

Adaptec 7211C

SNC 4500

Scalar 100

SDLT-320

Win2003

Win2000

CA ARCserve 11.1

1Gb

 

Adaptec 7211C

Table 2

Known Issues 

Change 

Request 

Number

Description

Workaround

PR00212

If the management port (mp) experiences 
excessive traffic, for example a Denial of Service 
(DoS) attack, the CPU cycles required to service 
this increase in traffic can impact performance.

Limit mp exposure to external 
network traffic.

PR00223

The SNC 4500 cannot download library firmware.

Use the library serial port or RMU 
to load library firmware.