Quantum Scalar i40 and Scalar i80:Power Supply Replacement
6-66559-02 Rev C
February 2014

4

Replacing a Power Supply with a Filler Plate

status of the power supply’s LED: the power supply LED should turn green 

immediately to indicate the library is turned on. 

Replacing a Power Supply with a Filler Plate

These instructions explain how to replace a power supply with a filler plate.

Note: On the Scalar i80

, if you are using only one power supply, you should 

install the power supply in the upper slot, and cover the lower slot with 

a filler plate (see 

Figure 1

 on page 1). 

1

Hold the filler plate with the thumbscrews at the top. 

2

Insert the bottom edge of the filler plate into the slot, engaging the bottom 

edge of the filler plate into the bottom of the slot. 

3

Pivot the filler plate up to fit securely in the hole.

4

Tighten the thumbscrews. 