Release Notes
Document 6-00016-32 Rev A
September 2007
Known Issues
5
Known Issues
0
This release of Scalar 10K firmware has the following known issues. This list contains
cumulative information for the previously released versions.
Change
Request
Number
Service
Request
Number
Description
Workaround
33359
282830
On occasion, the vertical mounting
of a 3590 tape drive might be higher
than the vertical window expected
by the library firmware to
successfully scan for the drive
fiducial. As a result, the library
cannot teach the drive.
Manually adjust the vertical
placement of the 3590 tape drive or
the front bezel until the library can
successfully teach the drive.
40518
When a Teach Current operation is
performed for a DM, a drive teach
failure can return an incorrect bay
number to the Operator Panel.
Physically inspect the drive bay that
the failure indicated or possibly the
bay that is located immediately
before. The bay that is identified by
the failure might not exist.
41203
When using a data tape instead of a
FUP tape to update a list of drives,
the library correctly posts a “BAD
FIRMWARE MEDIA” operator
intervention message, but continues
to the next drive in the list. The
operation should fail and not
continue.
No applicable workaround is
available.
41301
After cleaning cartridges are ejected
from drives, the View dialog (
Main
MenuSetupCleaningView
)
continues to indicate a Valid status
for the first cleaning cartridge rather
than clearing the status.
Make sure that cleaning cartridges
are inserted into the library by using
the Insert Clean Tape command
(
Main MenuCommands Insert/
EjectInsert Clean Tape
). This
operation physically inserts the
cartridges and also inserts them into
the library database.
NOTE: Do not use
Main Menu
SetupCleaningMedia
to perform
this operation. This operation inserts
the cartridges into the library
database only.