background image

Release Notes
Document 6-00016-32 Rev A
September 2007

4

Resolved Issues

2876

Logical serial number (12 character) causing configuration errors with 

TSM application.

2911

IVT test does not run LTO move cartridge test in 4th IE.

2931

418156

Library should compare drive fiducial labels with actual sled type.

2938

Service login timeout is handled incorrectly at "service->verify->all-

>perform all tests" screen if the 'Accept' input is 'y' when the timeout 

occurs. 

2939

Remove fibre channel topology and data rate selection for LTO-1 FC 

drives.

2974

S10K Tape alert flags are reported incorrectly in the S10K log and need a 

mechanism to report tape alert log data back to SDLC.

3024

550364

If the IE cable between the IE and the LMC becomes disconnected and a 

new teach is performed the teach fails with SAC 01, 40, A3.

3031

On large dual aisle systems, it has been observed that tower 13 sometimes 

fails to teach new on the secondary aisle side.

3032

566896

Serial number and logical serial number are truncated by 1 character on 

the operator panel.

3038

527016

E_LSC_WFSCRDBF_BAD_READBUFFER_HANDLE is reported with 

RMU 192 and 304 Library firmware.

3041

622572

If a LTO barcode label is printed in the reverse direction the library 

incorrectly places the label into the bottom cell and forces a rescan.

3045

Need to merge changes form CR64557(support of LB and LX media for 

3592 drives) onto main tree for 320.

3050

582456

On systems with a lot of drives (70+ drives), the Log sense page 3B 

interferes with vary on of drive causing SAC 71.

3071

Need to add changes (DDC\LDC\LBI boot \appl code problem 313 code) 

to 320 code.

3073

3592 drive modules power supply diags for the 4th drive bay do not work 

properly.

3074

S10K 314A FW does not identify media type and usage.

3075

3592 short media returns an incorrect media character through SCSI read 

element status.

3081

Code can take the library offline and not post an error.

3352

When varying a drive offline the library does not queue a unit attention 

until the menu is exited. It should queue the UA as soon as the drive has 

been varied offline and not wait for the user to exit the menu.

Change 
Request 
Number

Service 
Request 
Number

Description

Summary of Contents for Scalar 10K

Page 1: ...his Release 1 New Features and Enhancements 2 Compatibility Matrix 2 Resolved Issues 3 Known Issues 5 Documentation 6 Contacting Quantum 7 Purpose of This Release 0 The Scalar 10K 320 release includes...

Page 2: ...wing table for information on drive and auxiliary firmware compatibility with the 320 release of Scalar 10K 320A 00004 This information is current as of this product release For the most up to date in...

Page 3: ...r Description Version 320A 00004 1588 Aux trace screen shows tower numbers in hex 1589 Need change to display location of print log port 1727 Inserting AIT 3 tapes always causes retries Handling too h...

Page 4: ...e truncated by 1 character on the operator panel 3038 527016 E_LSC_WFSCRDBF_BAD_READBUFFER_HANDLE is reported with RMU 192 and 304 Library firmware 3041 622572 If a LTO barcode label is printed in the...

Page 5: ...e drive bay that the failure indicated or possibly the bay that is located immediately before The bay that is identified by the failure might not exist 41203 When using a data tape instead of a FUP ta...

Page 6: ...n MenuCommands Insert EjectInsert Clean Tape This operation physically inserts the cartridges and also inserts them into the library database NOTE Do not use Main Menu SetupCleaningMedia to perform th...

Page 7: ...nformation including answers to frequently asked questions FAQs You can also access software firmware and drivers through this site For further assistance or if training is desired contact Quantum For...