Quantum QT-730 Series Installation And Operation Manual Download Page 1

Manual Part No. DC30-003   Revision 

B

 

Model QT-730 Series 

 

Installation and Operation 

Manual 

Fixed Non-Float-Top 

 Enclosed Base Radiographic Table 

Summary of Contents for QT-730 Series

Page 1: ...Manual Part No DC30 003 Revision B Model QT 730 Series Installation and Operation Manual Fixed Non Float Top Enclosed Base Radiographic Table...

Page 2: ...ax 631 567 5074 This manual is copyrighted and all rights are reserved No portion of this document may be copied photocopied reproduced translated or reduced to any electronic medium or machine readab...

Page 3: ...graphic Table i Revision History REVISION HISTORY REVISION DATE TYPE OF MODIFICATION A 9 1 00 Initial Release B 2 15 01 Added UL Mark Page Number Rev Page Number Rev Page Number Rev i x B 1 34 B LIST...

Page 4: ...Model QT 730 Radiographic Table THIS PAGE INTENTIONALLY LEFT BLANK ii Revision History...

Page 5: ...el QT 730 Radiographic Table Table of Contents Section 1 Introduction 1 Section 2 Specifications 5 Section 3 Assembly Installation 11 Section 4 Operation 21 Section 5 Maintenance 27 iii Table of Conte...

Page 6: ...Model QT 730 Radiographic Table Table of Contents iv THIS PAGE INTENTIONALLY LEFT BLANK...

Page 7: ...serious injuries X RAY PROTECTION X rays are hazardous to both patient and operator unless established safe exposure factors and operating instructions are observed It is important that everyone havi...

Page 8: ...s described in publications such as Subchapter J of Title 21 of the Code of Federal Regulations Diagnostic X Ray Systems and Their Major Compo nents and NCRP Report No 102 Medical X Ray Electron Beam...

Page 9: ...ill be determined by a completed returned warranty card which must be returned within 30 days of system installation In no case shall the warranty exceed 15 months from the date of shipment If the war...

Page 10: ...quirements or operating environmental conditions in compliance with any applicable instruc tions or recommendations of Quantum Medical Imaging 2 Failure of Buyer Dealer to provide the proper incoming...

Page 11: ...ed parts shall become the property of Quantum Medical Imaging The preceding Paragraphs set forth Buyer s Remedies and Quantum Medical Imaging s sole liability for claims based upon failure of the prod...

Page 12: ...Model QT 730 Radiographic Table Warranty Information THIS PAGE INTENTIONALLY LEFT BLANK x...

Page 13: ...Chapter INTRODUCTION 1 1...

Page 14: ...2...

Page 15: ...proved radiography with minimum magnification Compact low maintenance design Enclosed base design i e welded on sheet metal covers surround the table base 650 lbs maximum patient load capacity Accept...

Page 16: ...PONENTS See Figure 1 The Model QT 730 Radiographic Table contains 1 Tabletop 2 Receptor Cabinet 3 Receptor Cabinet Lock Lever 4 Compliance Label 5 Table Base 4 Chapter 1 Introduction Figure 1 Radiogra...

Page 17: ...5 Chapter SPECIFICATIONS 2...

Page 18: ...6...

Page 19: ...o Film plane distance from 2 3 to 2 9 inches 58 4 to 73 7 mm Note Reduced length down to 60 inches 1524 mm is available reduces longitudinal travel distance Table Base Specifications Width 38 0 inches...

Page 20: ...Model QT 730 Radiographic Table 8 Chapter 2 Specifications Figure 2 Model QT 730 Dimensions...

Page 21: ...elative Humidity 20 to 80 non condensing Altitude 30 5 to 2440 meters relative to sea level Non Operating Environment Ambient Temperature 18 C to 70 C Relative Humidity 20 to 95 non condensing Altitud...

Page 22: ...Model QT 730 Radiographic Table 10 Chapter 2 Specifications THIS PAGE INTENTIONALLY LEFT BLANK...

Page 23: ...11 Chapter ASSEMBLY INSTALLATION 3...

Page 24: ...12...

Page 25: ...ist enclosed first Locate and re move the packing list Use the list as a guide to opening remaining cartons Do not dispose of packing material until packing list is matched with actual parts received...

Page 26: ...he event it is not 1 Position the Table Base see Figure 3 under the collimator in the approxi mate location where it is to be mounted 2 Place Table Top Frame on Table Base and secure using four 4 1 4...

Page 27: ...ack see Figure 5 Care fully lower the back end of the Receptor Cabinet so it rests on the Ta ble Top Frame where it mounts to the Table Base as shown in Figure 6 c Insert the left Rear Receptor Bearin...

Page 28: ...Model QT 730 Radiographic Table Chapter 3 Assembly Installation 16 Figure 6 Receptor Cabinet Resting on Table Base Figure 5 Front Receptor Bearings Resting on Rail FRONT RECEP TOR BEARING BRACKET...

Page 29: ...llation 17 Figure 7 Insert Left and Right Receptor Bearings on Track INSERT REAR RECEPTOR BEARINGS ON TRACK THROUGH SLOT IN BEARING RAIL Figure 8 Position Receptor Cabinet for Rear Receptor Bracket In...

Page 30: ...bucky route the bucky cable through the back of Table Base and up through the Table Top Frame Provide a service loop in cable such that there is no cable interference at any point throughout the full...

Page 31: ...collimator reduce the light field to a narrow beam of light along the length of the table 3 Position collimator to approximately 24 source to image distance SID 4 Insert a 14 x 17 cassette into the fi...

Page 32: ...front and back be sure that the leveling washers are in the proper position Use hard ware suitable for the type of floor in the installation and of sufficient strength to handle 100 lb pull out force...

Page 33: ...Chapter OPERATION 4 21...

Page 34: ...22...

Page 35: ...g the cabinet to the desired position Locking pulling up the Receptor Cabinet Lock Re lease Lever locks the cabinet in its new position WARNING All movable assemblies and parts of this equipment WARNI...

Page 36: ...Midwest type cassette tray proceed as fol lows 1 Pull cassette tray from Receptor Cabinet using tray handle see Figure 12 2 Pull back on front cassette grip opens both grips 3 Position slide guides L...

Page 37: ...ptor Cabinet using tray handle see Figure 13 2 Place thumb under lip of clamp handle Lift handle to release 3 Grasp handle and slide clamp back for inserting cassette 4 Insert cassette into tray back...

Page 38: ...Model QT 730 Radiographic Table Chapter 4 Operation 26 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 39: ...Chapter MAINTENANCE 5 27...

Page 40: ...28...

Page 41: ...inspection and maintenance of the Radiographic Table should be per formed by qualified service personnel on an annual basis WARNING Personnel engaged in maintenance activities should WARNING Personnel...

Page 42: ...trical cabling and wiring for wear and fraying Check all bearings and bearing surfaces for cleanliness and corrosion Conduct a general inspection for worn or damaged parts Visually inspect for wear an...

Page 43: ...Cabinet Repeat adjustment if necessary REPLACEMENT PARTS AND ORDERING INFORMATION Table 1 below provides a list of replaceable parts for the Radiographic Table Figures 15 through 17 show the location...

Page 44: ...Model QT 730 Radiographic Table Chapter 5 Maintenance 32 Figure 16 Replaceable Parts Location Diagram 3 Figure 15 Replaceable Parts Location Diagram 1 2...

Page 45: ...2905 Veterans Memorial Highway Ronkonkoma New York 11779 USA Phone 631 587 5800 Fax 631 567 5074 e mail info qmiteam com When ordering replacement parts supply the following information Model and seri...

Page 46: ...Model QT 730 Radiographic Table 34 Chapter 5 Maintenance THIS PAGE INTENTIONALLY LEFT BLANK...

Reviews: