21
ENGLISH
Cable length in meters
0 - 1,2
1,2 - 2,1
2,1 - 3,1
3,1 - 4,0
4,0 - 4,9
4,9 - 5,8
5,8 - 6,7
6,7 - 8,5
Fuse value in
Amperes
0 - 20
2,5
4
4
6
6
10
10
10
20 - 35
4
6
10
10
16
16
16
20
35 - 50
6
10
10
16
16
20
20
20
50 - 65
10
10
16
20
20
20
20
35
65 - 85
16
16
20
20
35
35
35
50
85 - 105
16
16
20
35
35
35
35
50
Minimum cable cross-section in mm
2
Recommended minimum cable cross-section to guarantee full amplifier performance:
Up to a length of 3 m: 10 mm
2
From a length of 3 m: 16 mm
2
Replace defective fuses only with a new one of the same type and with the same fuse rating.
CAUTION
FUSE
Socket for the device fuse (35 A).
5
REM IN/OUT (DO NOT USE)
By using the
AUTO TURN-ON
function (refer to page 22, section 9), the REM IN/OUT terminal does
not need to be connected. However, the REM IN/OUT terminal can then connected to the REM termi-
nal of another amplifier to provide a control signal to it (REM OUT function).
4
ADDITIONAL CABLE FUSE (NOT INCLUDED)
Install an extra fuse (not included) for the +12V power cable near the battery to secure the power
cable. The distance between the fuse and the battery should not exceed 30 cm. The fuse size must be
adapted to the cable cross-section of the installed power cable (refer to the table below).
IMPORTANT: The fuse on the battery does not protect the amplifier, but the cable between the battery
and the amplifier against short circuits.
6