background image

Release Notes
Document 5502252 Rev C
August 2008

4

Resolved Issues

PCR 14723

If there is a miss-match between the Cartridge Memory (CM) and the element type or 

barcode, the system will accept the element type.

PCR 14724

Address issues found in Cartridge Memory (CM) reads resulting in invalid densities after 

the drive is swapped.

PCR 14733

SR: 355614

With a bad tape drive, failing unload is taking 45 minutes and it should be 16 minutes.

PCR 16219

Improved the error message reported in the Remote Management Pages when the pass-

through elevator test has stopped with an error. 

PCR 17100

The Remote Management Pages do not reflect the library online state correctly (Java 

version 6 issue).

PCR 17370

State and Drive Activity fields always display 

unknown

.

PCR 17725

SR: 777244

Public SNMP community cannot be removed.

PCR 17847

SCSI Inquiry does not return the library serial number once a partition is named.

PCR 18206

SR: 798660

The library Remote Management Pages/ 

Setup SCSI/Fibre

 does not report the correct 

status.

PCR 19001

The Healthtest does not fail but logs a B506 event in the hard que.

PCR 19032

Add a test to move a cartridge from the top to the bottom of a library stack (and back)

PCR 19033

A Failed move to the Lower Pass-thru leaves the unit stuck in a Moving state.

PCR 19034

Remote Management Pages: Allow more than 15 chars in the Find Media ID area.

PCR 19037

Add specific text to failed get cartridge events.

PCR 19041

Improved media handling in the pass-through.

PCR 19042

Add an SNMP and E-mail event to inform user of a Host Reserve on the library.

PCR 19043

The OCP does not notify that the tape drive updated has completed when downgrade 

finishes.

PCR 19044

OCP: Drive operation screen is not correctly updated after drive power off.

PCR 19045

Prevents the Pass-through Elevator and the Hand can becoming FULL at the same time 

when moving tape cartridges from the Remote Management Pages

PCR 19051

The left door is opening up during power-on on some PX502 backplanes.

PCR 19096

Improve message if a user hits remove when no partition is selected/available.

PCR 19116

The WWNN need to be unique for each partition like SN - Networker autoconfig fails.

PCR 19185

Configuration of partitions is allowed (when it shouldn't be) with a Parallel SCSI or iSCSI 

library.

PCR 19258

SR: 818050

The library goes into an unexpected error state and the date and time are incorrect.

PCR 19288

SR: 815106

Allow the library to configure drives if drive found after the configuration process.

Change 

Request 

Number

Service 

Request 

Number

Description

Summary of Contents for PX500 Series

Page 1: ...0 6 and later versions Date August 2008 Contents 0 Purpose of This Release 1 New Features and Enhancements 2 Compatibility Matrix 2 Resolved Issues 3 Known Issues 6 Documentation 7 Contacting Quantum...

Page 2: ...ectivity Fibre When upgrading from a prior firmware revision this change may result in library not being available to the host in FC SAN configurations that employ persistent binding and or zoning in...

Page 3: ...hange Request Number Service Request Number Description PCR 3929 Failure B50B on PX502 during Z diagnostic test di test 7 PCR 4576 Improve message if user hits remove when no partition selected availa...

Page 4: ...y stack and back PCR 19033 A Failed move to the Lower Pass thru leaves the unit stuck in a Moving state PCR 19034 Remote Management Pages Allow more than 15 chars in the Find Media ID area PCR 19037 A...

Page 5: ...doesn t enforce APTPL bit PCR 19676 Reservation conflict status returned to host with a valid I_T nexus registration following library power cycle with APTPL bit set PCR 19852 Warn user that reconfig...

Page 6: ...he customer is able to view critical warning and information This will be corrected in future releases of library firmware PCR 19188 Remote Management Pages The drive firmware update does not refresh...

Page 7: ...y of the source code covered by the Open Source License contact the Quantum Technical Assistance Center Refer to Contacting Quantum below PCR 20130 The User password is rejected if it contains _ Do no...

Page 8: ...tacked Libraries 81 81289 A01 Software Interface Guide To order a copy of the source code covered by the Open Source License contact the Quantum Technical Assistance Center Refer to Contacting Quantum...

Reviews: