Battery Saver Feature

When the battery capacity drops to below 21V (typically two lights), the controller will reduce power 
chair performance to conserve battery power.

Sleep Mode (If Enabled)

The power chair controller features a sleep mode. Sleep mode is a built-in circuit that will automatically 
shut off the main power if the joystick is not moved in any direction for a period of time. This time factor 
is programmed into the controller. To restore power and continue, turn your power chair on.

Out of Neutral at Power Up (OONAPU)

Your power chair joystick is equipped with Out Of Neutral At Power Up (OONAPU). If you power up the 
system and the joystick is not in the neutral position, the system status light flashes rapidly for either 
as long as the joystick is out of the neutral position or five seconds. If this has happened and all of the 
battery condition meter lights are flashing, you may have set an error code. See “Error Codes.”

Error Codes

The system status light is displayed within the on/off key. This light is lit if the system is turned on. It 
also flashes in groups called error codes to indicate system faults. If your keypad displays one of these 
codes (

see Table 1

), contact your Pride/Quantum Provider.

NOTE: You must turn the controller off and then on again to reset the controller, even if the 

source of the error is removed/corrected.

In the event of an error, the system status light displays diagnostic indications. Errors are encoded 
as follows: one (DX Module fault) to twelve (module mismatch) and are displayed by the light flashing 
the number of times prescribed by the error code. The flash sequence (one to twelve) is followed by a 
long off period (2 seconds). If more than one error exists, then the error having the highest priority is 
indicated. The controller must be turned off and then on again even if the source of the error is removed. 
If you cannot resolve the problem, contact your Pride/Quantum Provider.

Summary of Contents for Europa

Page 1: ...Basic Operation Instructions I O Europa Controller...

Page 2: ...icon is represented as a white symbol on a blue dot with a white border PROHIBITED These actions are prohibited These actions should not be performed at any time or in any circumstances Performing a...

Page 3: ...troller 6 Operating the Europa Controller 10 Controller Communications Connector 13 Off Board Charger Socket 13 Power Accessory Control 13 Battery Saver Feature 14 Sleep Mode 14 Out of Neutral at Powe...

Page 4: ...portant for you to read them and understand them completely Read and follow the information in the owner s manual Avoid exposure to rain snow ice salt or standing water whenever possible Maintain and...

Page 5: ...on to the power base owner s manual that came with your power chair If there is any information in this manual which you do not understand or if you require additional assistance for setup or operatio...

Page 6: ...lity and braking If it is programmed incorrectly or outside of the safe limits as determined by your healthcare professional it can create a dangerous situation Only the power chair manufacturer an au...

Page 7: ...ll phones two way radios laptops electricity generators or high power sources and other types of radio transmitters may cause unintended movement of your electrically powered mobility vehicle due to E...

Page 8: ...l The joystick is used to control the direction and speed of the power chair Actuator Adjustment The user can control positioning of power seat actuators with the Europa Drive Profile Selection The us...

Page 9: ...Magnetic Key Lock System is not in use System Status Light Indicates the On Off status of the power chair and flashes to indicate system faults Magnetic Key Lock System LED Magnetic key used to power...

Page 10: ...allow it to return to the neutral position you engage the electromagnetic brakes This causes your power chair to decelerate and come to a complete stop Keypad The keypad is located directly in front o...

Page 11: ...11 1 0 1 2 3 4 Figure 2 Europa Controller Figure 3 Europa Keypad...

Page 12: ...rn off itself Battery Condition Meter The battery condition meter consists of six lights arranged in an arc over the battery icon From left to right the first two are red the second two are orange and...

Page 13: ...essory actuators are selected and controlled using the joystick To select a power accessory actuator 1 Press the drive program select key until the 7 segment display displays A NOTE The power chair wi...

Page 14: ...eter lights are flashing you may have set an error code See Error Codes Error Codes The system status light is displayed within the on off key This light is lit if the system is turned on It also flas...

Page 15: ...otor brake itself is shorted Check motor brake wiring 6 Right Park Brake or connection Fault The connection between the power module and the right motor brake is either open or shorted or the motor br...

Page 16: ...16...

Page 17: ...17...

Page 18: ...18...

Page 19: ......

Page 20: ...ire OX26 4UL www quantumrehab co uk Australia 20 24 Apollo Drive Hallam Victoria 3803 www quantumrehab com au New Zealand 38 Lansford Crescent Avondale Auckland New Zealand 1007 www pridemobility co n...

Reviews: