background image

ELM2LF

EMERGENCY LIGHTING UNIT

Installation and wiring …………………..…………......…………………………………… P. 2-3
Testing and maintenance ………...…………………………………………………………P. 4-5

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions

should always be followed, including the following:

!
!

!

!

!

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

WARNING: 

FAILURE TO FOLLOW THESE INSTRUCTIONS AND WARNINGS MAY RESULT IN DEATH, SERIOUS INJURY OR

SIGNIFICANT PROPERTY DAMAGE

- For your protection, read and follow these warnings and instructions carefully before installing or 

maintaining this equipment. These instructions do not attempt to cover all installation and maintenance situations. If you do not understand 

these instructions or additional information is required, contact Lithonia Lighting or your local Lithonia Lighting distributor.

WARNING:

RISK OF ELECTRIC SHOCK – NEVER CONNECT TO, DISCONNECT FROM OR SERVICE WHILE EQUIPMENT IS 

ENERGIZED

.

WARNING:

DO NOT USE ABRASIVE MATERIALS OR SOLVENTS. USE OF THESE SUBSTANCES MAY DAMAGE FIXTURE, 

WHICH MAY RESULT IN PERSONAL INJURY.

WARNING

RISK OF PERSONAL INJURY – This product may have sharp edges. Wear gloves to prevent cuts or abrasions when removing

from carton, handling, installing and maintaining this product.

WARNING: 

The battery used in this device may present a risk of fire or chemical burn if mistreated. Do not disassemble, heat above 70° C    

(158° F), or incinerate. Replace battery only as directed on the battery label and page 5 of these instructions. Use of unauthorized battery voids 

warranty and UL listing of this product, and may present a risk of fire or explosion.

•Disconnect A.C. power before servicing.

•All servicing should be performed by qualified personnel.

•Consult your local building code for approved wiring and installation.

•Do not use outdoors unless used with Acuity Brands accessories appropriate to the application.

•Do not mount near gas or electric heater.

•Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.

•The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.

•Do not use this equipment for other than intended use.

SAVE THESE INSTRUCTIONS

AND DELIVER TO OWNER AFTER INSTALLATION

“TEST” button / status 

indicator

Press latches to disengage 

housing from mounting plate

Remote test option

NOTE:

Product versions that comply with CA Title 20 are marked  BC  on the product label.

Summary of Contents for ELM2LF

Page 1: ...abrasions when removing from carton handling installing and maintaining this product WARNING The battery used in this device may present a risk of fire or chemical burn if mistreated Do not disassemble heat above 70 C 158 F or incinerate Replace battery only as directed on the battery label and page 5 of these instructions Use of unauthorized battery voids warranty and UL listing of this product a...

Page 2: ...mp Wires If no remote lamps are connected remote lamp leads and low voltage DC should be left capped and dressed in mounting plate as shown Taking care not to pinch wires or connectors dressed inside junction box secure mounting plate to junction box screws NOTE To ensure proper engagement of the mounting plate latches to the housing DO NOT OVER TIGHTEN THE SCREWS At upper center of the mounting p...

Page 3: ...ect the polarized battery plug to the charger board Make certain that the battery cable is routed to avoid interference with the AC input connector or other components Federal Communications Commission FCC Requirements This device complies with Part 15 of the FCC Rules This device may not cause harmful interference battery connector Battery Lamp Lamp Status Indicator LED Remote test Option standar...

Page 4: ...henever the total connected lamp load of the unit is changed or a lamp is replaced NOTE Manual load learning functions cannot be initiated if there is inadequate charge in the batteries If this is so wait until the unit indicates full battery charge solid green status indication before initiating the manual load learning function Clearing a failure indication After a failure condition has been cor...

Page 5: ...essing the assembly toward the inside of the unit Gently bend the snap at each side of the bracket to release the lamp assembly Cut wires near lamp board and strip back 1 4in Connect stripped wires to the replacement lamp following the yellow blue polarity as marked Secure the new lamp assembly onto the lamp bracket and re assemble it into the housing routing the lamp wires to avoid damage by othe...

Page 6: ...Part 912 00026 001 Rev C 1 15 2018 Acuity Brands Lighting Inc 2018 All Rights Reserved LIFE SAFETY SOLUTIONS TEL 800 334 8694 www lithonia com ...

Page 7: ...ararlo ADVERTENCIA La batería utilizada en este dispositivo puede presentar un riesgo de incendio o quemadura química si no se utiliza correctamente No desmontar calentar a más de 70 C 158 F o incinerar Cambie la batería solo como se indica en la etiqueta de la batería y en la página 5 de estas instrucciones El uso de una batería no autorizada anula la garantía y la certificación UL de este produc...

Page 8: ...os y colocados dentro de la placa de montaje como se muestra Teniendo cuidado de no presionar los cables o conductores organizados dentro de la caja de unión fije la placa de montaje a los tornillos de la caja de unión NOTA Para asegurar que los pestillos de la placa de montaje estén correctamente enganchados a la carcasa NO AJUSTE DEMASIADO LOS TORNILLOS En la parte superior del centro de la plac...

Page 9: ...atería polarizado a la placa del cargador Asegúrese de verificar el recorrido del cable para evitar interferencias con el conector de entrada de CA o con otros componentes Requisitos de la Comisión Federal de Comunicaciones FCC Este dispositivo cumple con la Parte 15 de las reglas de la FCC Este dispositivo puede no ocasionar interferencias perjudiciales conector de la batería Batería Lámpara Lámp...

Page 10: ... la lámpara conectada esté totalmente cargada o que una lámpara sea reemplazada NOTA Las funciones de aprendizaje de carga manuales no pueden iniciarse si las baterías no tienen carga suficiente Si esto es así espere hasta que la unidad indique que la batería ha sido totalmente cargada indicador de estado verde fijo antes de iniciar la función de aprendizaje de carga manual Aclaración de indicacio...

Page 11: ... la lámpara y tira hacia atrás 1 4in Conecte los cables pelados a la lámpara de reemplazo siguiendo la polaridad amarilla azul marcada Sujete el nuevo el ensamblaje de la lámpara al soporte de la lámpara y vuelva a montarlo en la carcasa y direccione correctamente los cables de la lámpara para evitar daños de otros componentes Vuelva a ensamblar la unidad consulte también el paso 5 en la página 3 ...

Page 12: ...N º de pieza 912 00026 001 Rev C 1 15 2018 Acuity Brands Lighting Inc 2018 Todos los derechos reservados SOLUCIONES DE SEGURIDAD PERSONAL TELÉFONO 800 334 8694 www lithonia com ...

Reviews: