background image

QE7044 

INSTALLATION INSTRUCTIONS 

 

 

 

ALL ELECTRICAL WORK SHOULD BE CARRIED OUT BY A COMPETENT ELECTRICIAN 

 

 

1  Decide on a suitable location. 

 

2  Mark the position for the 2 No.8 Woodscrews. (supplied) 

 

3  Fit the screws leaving the screws protruding 15mm from the wall.  

 

4  Mark the position on the wall for the 13A Fused Spur connection. 

 

5  Install the fused spur back box and supply cable. (Surface mount or sunken)  

 

6  Mount the heater on to the 2 off No.8 Woodscrews. 

 

7  Ensure that the mains supply is turned off. 

 

8  Connect the supply to the fused spur front plate. 

 

9  Connect the unit to the front plate as described below. 

 

10  Replace the front plate. 

 

11  Installation is now complete. 

 
CONNECTION DETAILS 
 

THIS UNIT MUST BE CONNECTED TO THE MAINS SUPPLY BY A SWITCHED SPUR 

 

The wires in the cable attached to this unit are coloured in accordance with the following code:- 

 

BROWN 

====================== 

LIVE 

 

GREEN/YELLOW 

===

=

===

=

===

=

===

=

===

=

==

 

EARTH 

 

BLUE 

====================

  

NEUTRAL 

 

THIS APPLIANCE MUST BE EARTHED 

 
As the colours may not correspond with the markings indentifying the terminals in the fused spur proceed as follows. 
 

 

Blue wire must be connected to the terminal marked ‘N LOAD’ 

 

Brown wire must be connected to the terminal marked ‘L LOAD’ 

 

Green/Yellow wire must be connected to the terminal ‘E’ or marked 

 

 

Summary of Contents for QE-7044

Page 1: ...the box should also contain the following items The most important item is a QE 7044 wall heater 1 Remote control 2 Woodscrews 35 mm long 2 plastic wall plugs used for fixing the heater to a brick or concrete wall If there is anything missing or you have any questions please call 05602 045420 between 8 00am and 4 00pm Mon to Fri and we will do our best to help you We can be contacted by email at s...

Page 2: ... supply to the fused spur front plate 9 Connect the unit to the front plate as described below 10 Replace the front plate 11 Installation is now complete CONNECTION DETAILS THIS UNIT MUST BE CONNECTED TO THE MAINS SUPPLY BY A SWITCHED SPUR The wires in the cable attached to this unit are coloured in accordance with the following code BROWN LIVE GREEN YELLOW EARTH BLUE NEUTRAL THIS APPLIANCE MUST B...

Page 3: ...on the remote control to switch on the FAN and open the vanes Pressing the HEATER button will select the low heat setting 1000W Press the HEATER button again to select the high heat setting 2000W The ambient temperature of the room can be controlled from 18C to 30C by pressing the UP or DOWN to select the required temperature The timer can be set from hour to 7 hours by pressing the TIMER button w...

Page 4: ...vicinity of bathtubs showers wash basins or swimming pools Do not leave switched on unattended overnight Do not use outdoors Do not use this appliance for other than its intended purpose This appliance is for interior use only Do not attempt to repair disassemble or modify the appliance in any way There are no user serviceable parts inside Do not insert or allow to be inserted any foreign objects ...