Quantek C Prox WAVE500-2B Manual Download Page 2

 

 

 

TECHNICAL CHARACTERISTICS 

 

WAVE500-2 

WAVE500-2B 

Frequency 

868.35MHz 

Coding 

High security rolling code 

Memory 

500 codes 

Number of relays 

2 (expandable to 4) 

Supply 

230Vac 

12/24Vac/dc 

Power supply range 

±10% 

9-23 / 22-35Vdc 
8-16 / 16-27Vac 

Relay contacts 

1A 

Standby/Op. consumption 

35mA / 50mA 

60mA / 350mA 

Access control output 

(3 readers max without external power supply) 

BUS-L 

Op. temperature 

-

20⁰C to +85⁰C

 

Watertightness 

IP54 (with glands IP65) 

Box dimensions 

140x220x55mm 

 

 
INSTALLATION AND CONNECTIONS 

 

Attach the rear part of the housing to the wall using the plugs and screws provided. Pass the cables 
through the bottom of the receiver. Connect the power cables to the terminals marked on the circuit 
board, as indicated. Connect the relay outputs and access control readers as required. Fix the receiver 
cover to the rear part using the screws provided. 
 

 

OPERATING 

The pilot lights are activated every 5 seconds to indicate the correct power supply to the equipment. 
Upon receiving a code, the receiver checks whether it is in its memory, activating the corresponding relay. 
The relay activation mode is selected in either impulse or on/off using the Imp/Bies jumper (only with relay 
2). 

 
PROGRAMMING 

MANUAL PROGRAMMING 

Press the receiver programming button for 1 second, an acoustic signal will be heard, release the button. 
The  receiver  will  enter  standard  programming  (see  table).  If  the  receiver  programming  button  is  held 
pressed down, the receiver will enter special programming, cyclically passing from one configuration to the 
next. Once the programming configuration for the transmitter to be registered has been chosen, send the 
code to be programmed by pressing the transmitter. Every time a transmitter is programmed, the receiver 
will issue an acoustic signal for 0.5 seconds.  
After  10 seconds without programming or pressing the first two transmitter buttons, the receiver will exit 
programming mode, issuing two acoustic signals of 1 sec. If upon programming a transmitter the receiver 
memory is full, it will issue 7 acoustic signals of 0.5 sec. and exit programming. 
 