F
RONT
P
ANEL
U
SER
I
NTERFACE
BMC
3-4
11
FAN_SYS0
FAN_SYS1
FAN_SYS2
FAN_SYS3
FAN_SYS4
FAN_SYS5
Fan_SSD0*
Fan_SSD1*
* It depends on physical plat-
form
Lower Critical Going low
Lower Non-Critical Going low
12
Volt_P3V3
Volt_P5V
Volt_P12V
Volt_P1V05
Volt_P1V8_AUX
Volt_P3V3_AUX
Volt_P5V_AUX
Volt_P3V_BAT
Lower Critical Going low
Upper Critical Going High
13
PSU1 Status
PSU2 Status
0: Presence detected
1: Power supply failure detected
2: Power supply input lost (AC/DC)
14
PSU Redundancy
1: Redundancy Lost
15
Event Log
4: SEL Full (909 records)
5: SEL almost full (909 x 75% = 681 records)
16
Watchdog
0: Timer Expired
1: Hard Reset
2: Power Down
3: Power cycle
17
System Event
4: PEF Action
18
Critical IRQ
0: Front Panel NMI / Diagnostic Interrupt
19
CATERR
1: State Asserted
20
PSU1 Input
PSU2 Input
HSC0 Input
Lower Critical Going low
21
PDB Event*
* It depends on physical plat-
form
0: PDB Abnormal Reset (A, R)
1: PDB Pre-test Failed (A, R)
2: Programming HDD repeater failed (A, R)
3:Linking Board status error
4: Over Current Protection
Table 3.2: Status LED Activity (Continued)
N
O
.
S
TATUS
LED A
CTIVITY
D