5

material and may require replacement every 7 to 10 years.  When the Bio-COIR media has reduced in 
volume by 50%, and the effluent quality fails to meet minimum regulatory requirements, it needs to be 
replaced.  The open cell foam media is warranted to be free from defect 
for 10 years. If the media shows degradation after that time and the efflu-
ent quality fails to meet minimum regulatory requirements, new media 
should be added. When replacing either media, make sure to compact it 
below the spray nozzle by approximately 4-6 inches to make certain that 
the spray nozzles function properly.
3. Remove the spray nozzle by unsnapping the stainless steel spring from 
the pipe.  Clean any debris and replace them.  The spray nozzle piping 
can be removed at the unions and cleaned with a bottle brush or water 
pressure if needed.

NOTE: If effluent samples are needed, a grab sample can be taken by placing the sample bottle below the 
out fall of the recirculation device, being careful not to touch the bottle to any contaminated surface.  The 
effluent sample should be collected and transported according to the testing facility requirements. Efflu-
ent should be clear with a slight yellow tint and should be free 
from odor. Effluent results should be in accordance with NSF 
Standard 40 Class 1 requirements, BOD less than 25mg/L and 
TSS less than 30mg/L.

Section 7.0 Recirculation Device

1.  Check  to  see  if  the  stainless  steel  rod  is  moving  up  and 
down freely.  Also, check to see if the ball float is located at 
the proper level.  When the ball float is at its lowest position, 
it should be located equal to or just above the on position of 
the timer enable float. (figure 1)
2. Check that the design recirculation rates are maintained by observing the discharge through all five out 
falls of the recirculation assembly.  Adjust as needed by loosening the quick disconnects and leveling. 

TROUBLESHOOTING GUIDE

The AeroCell

®

 & Bio-COIR

®

 systems will handle all domestic wastewater from your home. By the term 

wastewater we are referring to rapidly biodegradable material. To keep maintenance at a minimum level 
and to prevent the system from malfunctioning, the following guidelines need to be followed:
* Since aerobic bacteria are responsible for treating the wastewater, inorganic or non-rapidly biodegrad-

able materials should not be put into the system. Examples of improper items are:  plastic products, 
rubber products, sanitary napkins or tampons, washcloths, cigarette butts, coffee grounds, eggshells, 
matches, or other non-biodegradable objects.

* Do not dispose of cooking grease or large amounts of oil into system; instead pour it into a container 

and dispose of it properly.

* To minimize pump-out frequency, limit use of garbage disposals.
* Lint from lint catchers, hair, etc., should be disposed in the trash and not washed down the drain.
* Water softener backwash should not be routed through the system.  Another source of disposal should 

be used.

* Diapers can be rinsed out in the toilet; however, do not flush cloth or disposable diapers down the toi-

let.

* Large amounts of harsh chemicals, high sudsing detergents, disinfectants or any substance that kills bac-

teria must not be discharged into the system.

Figure 1

Summary of Contents for AeroCell ATS-SCAT-86-AC-C750

Page 1: ...ESTWOOD KY 40014 FAX 502 992 8249 www quanics net CLASS I NSF STD 40 WASTEWATER TREATMENT SYSTEM OPERATION MAINTENANCE MANUAL MANUFACTURED PRODUCTS BY QUANICSTM FIXED FILM MEDIA WASTEWATER TREATMENT SYSTEMS Revised August 2007 E n g i n e e r i n g Water S o l u t i o n s ...

Page 2: ...ic Tank 3 Section 2 0 A300 8 Series Effluent Filter 3 Section 3 0 Dosing Tank 4 Section 4 0 Filtered Pump Vault 4 Section 5 0 Controls Pumps Floats 4 Section 6 0 Treatment Module 4 Section 7 0 Recirculation Device 5 TROUBLESHOOTING GUIDE 5 6 SAFETY 6 DRAWINGS TECHNICAL DATA 7 19 WIRING SCHEMATICS 20 21 DATA PLATES 21 ...

Page 3: ...ms utilizing fixed film media The module s consist of a fiberglass tank s containing a pre determined amount of media Ef fluent is sprayed over the media utilizing specialized spay nozzles This patented delivery system evenly distributes wastewater to achieve the desired treatment levels The AeroCell utilizes open cell foam media The foam has a high porosity large surface area and ease of microbia...

Page 4: ...nable float is down the pump will need to be activated manually by switching the HOA switch in the control panel to HAND 6 While the pump is running observe the spray nozzles in the treatment module for flow and pressure 7 While the pump is running observe the recirculation device for proper flow 8 Once the current operating condition of the system is established turn the HOA switch to the OFF pos...

Page 5: ...ned 2 Remove the filter panel Rinse the filter plates with fresh water making sure all septage is rinsed back into the tank The filter plates should be cleaned until all slots are open and free of de bris 3 Replace the filter panel and remove the white maintenance plate Repeat steps 1 and 2 for the second filter panel Section 5 0 Controls Pump Floats 1 Inspect the floats for proper placement and m...

Page 6: ...located at the proper level When the ball float is at its lowest position it should be located equal to or just above the on position of the timer enable float figure 1 2 Check that the design recirculation rates are maintained by observing the discharge through all five out falls of the recirculation assembly Adjust as needed by loosening the quick disconnects and leveling TROUBLESHOOTING GUIDE T...

Page 7: ...ridge has been removed b Check the septic tank to see if it appears normal If not check with the PROPERTY OWNER to determine what inappropriate materials might have been added to the waste stream 3 Recirculation device is not splitting properly a Check the out falls for clogging b Check the device for level 4 Control panel malfunction a Check all fuses and breakers b Check originating power source...

Page 8: ...sory personnel Follow these safety precautions when performing any excavation or construction work Follow all construction safety procedures during installation Follow electrical safety procedures during installation Fill all holes and depressions in and around the installation area remove and dispose of all debris from installation TECHNICAL DATA DRAWINGS INDEX ATS SCAT 8 AC C500 8 PDS ED 1 5 16 ...

Page 9: ...uanics net autocad htm 750 GPD AeroCell System www quanics net autocad htm The septic tank shall have a minimum L W ratio of equal to or greater than one The septic tank shall have a minimum L W ratio of equal to or greater than one ...

Page 10: ...uanics net autocad htm 1250 GPD AeroCell System www quanics net autocad htm The septic tank shall have a minimum L W ratio of equal to or greater than one The septic tank shall have a minimum L W ratio of equal to or greater than one ...

Page 11: ...nics net autocad htm The septic tank shall have a minimum L W ratio of equal to or greater than one The septic tank shall have a minimum L W ratio of equal to or greater than one 500 gallons per day 85ft3 of Bio COIR media 5 88 gpd ft3 hydraulic loading rate Four 120 degrees spray nozzles ...

Page 12: ...L W ratio of equal to or greater than one The septic tank shall have a minimum L W ratio of equal to or greater than one 750 gallons per day 138ft3 of Bio COIR media 5 88 gpd ft3 hydraulic loading rate Eight 120 degrees spray nozzles 1000 gallons per day 170ft3 of Bio COIR media 5 88 gpd ft3 hydraulic loading rate Eight 120 degrees spray nozzles ...

Page 13: ... W ratio of equal to or greater than one The septic tank shall have a minimum L W ratio of equal to or greater than one 1250 gallons per day 223ft3 of Bio COIR media 5 88 gpd ft3 hydraulic loading rate Twelve 120 degrees spray nozzles 1500 gallons per day 255ft3 of Bio COIR media 5 88 gpd ft3 hydraulic loading rate Twelve 120 degrees spray nozzles ...

Page 14: ...AT 886 BC C1250 1250 12 3 223 5 61 2500 1250 76 8 15 3 81 ATS SCAT 888 AC C1500 ATS SCAT 888 BC C1500 1500 12 3 255 5 88 3000 1500 76 8 15 3 98 The Zabel A300 8x18 VC model effluent filter is used in systems of 1200 gpd or less The A300 8x26 VC filter is used in systems up to 1800 gpd The septic tank shall have a minimum L W ratio of equal to or greater than one Features Effluent discharge and car...

Page 15: ...on Outlet hub accepts 4 or 6 SCH 40 outlet pipe All Zabel Filters accept SmartFilter alarm switch GPD Maximum Gallons Per Day FS Filtration Size Warranty for Defects in Material and Workmanship Effluent Filters Limited Lifetime FILTERED PUMP VAULT Hanging FPV H44 4 FPV H56 4 High density non corrosive polyethylene plastic with stainless steel screws Features Hanging filtered pump vault installs in...

Page 16: ... 3M 300 V SJOW jacketed 2 wire with ground Materials of Construction 300 grade stainless and cast iron Discharge 1 1 2 Warranty for Defects in Material and Workmanship All components 3 Years STEP SYSTEMS Effluent Discharges PDS ED 1 5 Materials Pipe 1 5 or 2 SCH 40 PVC 1 5 or 2 PVC flex tubing True Union Ball Valve PVC Plastic Double block full port design 1 5 or 2 slip slip hubs Fittings SCH 40 P...

Page 17: ...Years PDS GT 2 0 STEP SYSTEMS Float Tree AC FT 3 Materials Pipe 1 5 or 2 SCH 40 PVC 1 5 or 2 PVC flex tubing True Union Ball Valve PVC Plastic Double block full port design 1 5 or 2 slip slip hubs Fittings SCH 40 PVC threaded slip adapter SCH 40 PVC slip slip adapter Warranty for Defects in Material and Workmanship All components 2 Years ...

Page 18: ... electrical lines HOA Switch for manual pump control mounted on cir cuit board Float Switch Terminal Block Alarm and Control Fuses Programmable Timer with separate variable controls al lows for setting the on and off times from 05 seconds to 30 hours Circuit Breaker provides pump disconnect and branch circuit protection Power Supply Pump 120 208 240V 7 15FLA Alarm 120V Standard Alarm Package Red A...

Page 19: ...charge Assembly 2 Years Float Valve Assembly 2 Years ATS GRD 100 80 20 N Materials Risers and Lids High density non corrosive polyethyl ene plastic Stainless steel screws Neoprene gasket IMPORTANT When adding risers together for deeper installations QUANICS does not recommend exceeding a maximum depth of 48 Neoprene gaskets must be installed as per instructions To prevent unauthorized entry instal...

Page 20: ...19 Wiring Schematics ...

Page 21: ...20 Consecutively Serial Numbered Data Plates Maintenance Sticker ...

Page 22: ...TY OWNER Responsibilities The PROPERTY OWNER confirms that he has read and understands the AeroCell Bio COIR Operation Manual and agrees to operate the QUANICS AeroCell Bio COIR Advanced Treatment System in accordance with QUANICS s oper ating instructions Failure to use the system in accordance with the Operation Manual will void all warranties All repairs required to restore the system to normal...

Page 23: ...om the date of installation pumps for a period of three years from the date of installation and AeroCell Bio COIR foam for a period of ten years from the date of installation Failed warranted parts shall be prorated over the period of use with cost calculated at the list price at the time of failure Discontinued parts will be replaced with the closest current QUANICS equivalent In no event shall Q...

Page 24: ...OX 1520 PHONE 502 992 8200 6244 OLD LAGRANGE ROAD 1 877 QUANICS CRESTWOOD KY 40014 FAX 502 992 8249 www quanics net Treatment system service provider 082707 326 E n g i n e e r i n g Water S o l u t i o n s ...

Reviews: