Models Q4P09H, Q4P09X & Q4P09W
Installation, Operation and Maintenance
4
Rev 12/26/13
Q4P09-IOM-Q.doc
WARNING
V
ERTICAL
C
LEARANCE
Check the height of the area where the lift is to be
installed. Clearance should be calculated based on
the full raised height of the lift.
Failure by purchaser to
provide adequate clearance
could
result
in
unsatisfactory lift performa nce, property
damage, or personal injury.
F
LOORING
Be certain you have the proper concrete floor to
properly handle the loaded lift. Floor should be in
generally good condition with no large cracks,
spalling or deterioration.
Minimum requirements for concrete are 4
inches
minimum
depth,
with
steel
reinforcement, 3500 psi, cured for 28 days per
local commercial practice
. This lift is designed to
accommodate a 3 inch total variation in elevation
at the base of the four posts. Floor should be level
within 1/2 inch from side-to-side and 2 1/2
front-to-rear to avoid special shimming. No
anchors should be installed within 8 inches of any
crack, edge, or expansion joint. If these conditions
cannot be met, a pad may be poured to
accommodate the lift.
Check with local building inspectors and/or permits
office for any special instructions or approvals
required for your installation.
Failure by purchaser to
provide the recommen ded
mounting surface could
result in unsatisfactory lift performance,
property damage, or personal injury.
L
OCATION
This lift has been evaluated for indoor use only
with an operating ambient temp. range of 5 – 40°C
(41-104°F)
E
LECTRICAL
R
EQUIREMENTS
For lift installation and operation for single
phase units, it is necessary to have a dedicated
circuit with a single pole (11 5v) or Double pole
(230v) circuit breaker or time d elay fuse sized
for the following Full Load (FL) Amperage:
The 115V power unit FL amperage is 15 amps.
The 230V power unit FL amperage is 18 amps.
For lift installation and operation with standard
power unit, it is necessary to have a dedicated
115V single-phase 60-cycle circuit with a 20 amp
circuit breaker or time delay fuse
For lift installation and operation with 230V power
unit, refer to
Fig 24
.
S
AFETY
N
OTICES AND
D
ECALS
For your safety, and the safety of others, read and
understand all of the safety notices and decals
included here.
R
EAD ENTIRE MANUAL BEFORE ASSEMBLING
,
INSTALLING
,
OPERATING
,
OR SERVICING THIS
EQUIPMENT
.
P
ROPER MAINTENANCE AND INSPECTION IS
NECESSARY FOR SAFE OPERATION
.
DO
NOT
OPERATE A DAMAGED LIFT
.
Safety decals similar to those shown here are
found on a properly installed lift. Be sure that all
safety decals have been correctly installed on the
Power Unit reservoir. Verify that all authorized
operators know the location of these decals and
fully understand their meaning. Replace worn,
faded, or damaged decals promptly.
Do not attempt to raise a
vehicle on t he lift until the
lift has b een correctly
installed and adjusted as described in this
manual.
WARNING
WARNING