background image

Health and fresh!

 

 

 

8

   

Step 1: Select the position for installing the heater on the ceiling, and remove the 3 
aluminum gussets in the installation position and the 3 aluminum gussets in the side. 

 

Step 2: Right above the installation position of the heater, Make a 10mm diameter   
bolt hole with a percussion drill , insert the stainless steel expansion bolt,                             
and fix the "expansion screw fixing plate",The hole spacing between 
the two "expansion screw fixing plates" is 600mm. 

 

Step 3: Install the wire rope in the wire groove of regulator holder. 

 

 

 
 

Summary of Contents for QH16-18A

Page 1: ...carefully before setting up and operating this unit This manual is designed to provide you with important information needed to setup operate maintain for your radiant heaters Failure to follow these instructions may damage and or impair its operation and void the warranty ...

Page 2: ...r with other appliances in case of current overload Make sure the plug and socket good contact 4 Please pull plugs out when power off Do not pull wires by hands 5 Please stop power immediately once heaters failure or wires are broken Users can not repair heaters by themselves Please contact authorized servicer for maintenance if heaters failure 6 Radiant heater cannot be placed directly below the ...

Page 3: ...design and manufacturing technique Using a specially coated aluminum panel the heat generated by the heating element is transferred radiantly to people and objects with maximum efficiency The heat radiated from the panel surface is absorbed by people walls floors and furniture etc like sunshine Infrared heating will not lead to air movement making the air cleaner as dust and particles are not dist...

Page 4: ...he heat The air remains less humid and gives you a sense of fresh comfortable warmth similar to the warmth felt from the sun 5 WORKING CONDITION Ambient temperature 30 40 Rated Voltage 220 240V Rated frequency 50Hz 60Hz Relative humidity less than 95 6 INSTALLATION REQUIREMENTS 1 Qualified installer The installation must be carried out by trained personnel 2 Installation conditions 1 Supply voltag...

Page 5: ...Health and fresh 4 7 SPARE PARTS Expansion screw fixing plate 2pc Stainless steel expansion bolt 2pc 8 INSTALLATION INSTRUCTION JH NR16 18A Specifications Installation decomposition ...

Page 6: ...n position of the heater make a 10mm diameter bolt hole with a percussion drill insert the stainless steel expansion bolt and fix the expansion screw fixing plate The hole spacing between the two expansion screw fixing plates is 355mm Step 3 Install the wire rope in the wire groove of regulator holder Step 4 Ensure the surface of the heater is flush with the aluminum gusset by adjusting the length...

Page 7: ...Health and fresh 6 Step 5 Connect the lead wires of the heater to the corresponding power cable Note Make sure the product is completely grounded Step 6 Reinstall the removed aluminum gussets ...

Page 8: ...Health and fresh 7 8 INSTALLATION INSTRUCTION Specifications Installation decomposition ...

Page 9: ...uminum gussets in the side Step 2 Right above the installation position of the heater Make a 10mm diameter bolt hole with a percussion drill insert the stainless steel expansion bolt and fix the expansion screw fixing plate The hole spacing between the two expansion screw fixing plates is 600mm Step 3 Install the wire rope in the wire groove of regulator holder ...

Page 10: ...heater is flush with the aluminum gusset by adjusting the length of the wire rope Step 5 Connect the lead wires of the heater to the corresponding power cable Note Make sure the product is completely grounded Step 6 Reinstall the removed aluminum gussets ...

Page 11: ...lure Does wire connection correct Equipment failure Does electricity ground connected safely There is electricity leakage risk 10 ATTENTION Due to thermal expansion and contraction the heater would make noise when turning on or off It s a normal phenomenon and won t make bad affection 11 INSPECTION ITEMS FOR COMMISSIONING 1 Do not connect power until installation is complete 2 All wires connection...

Page 12: ...IST No Name QTY 1 Heater 1 pc 2 Expansion screw fixing plate 2 pc 3 Stainless steel expansion bolt M8 60 2pc 13 SPECIFICATIONS Model No Dimension mm Package size mm Net weight kg Gross weight kg QH16 18A 600 300 90 650 355 150 6 2 7 3 ...