POWER 

(

1

) power switch may be set in two positions: 

O

 - lamp switched off,

I

 - mains supply,

You can connect the power cord only if the switch is set to  

O

  position. Failure to

comply to this recommendation may damage the device.

2. After the power cord is connected to the device, turn the lamp's switch (

1

) to 

I

 position.

Light Output Adjustment

Light output may be adjusted with a knob (

3

). To reduce the brightness, turn the knob in the counter clockwise

direction. To increase the power, turn the knob in the opposite direction.

Fuse Replacement

The device is equipped with a 10A (

2

) fuse; its socket is located above the power socket. If the lamp stops

working, check if the fuse has not been blown. A blown fuse should be replaced with a fuse of the same type
and parameters (10A). It is forbidden to use fuses featuring different parameters. Fuse should be replaced only
if the lamp is disconnected from power supply, and the device's switch (

1

)

 

is set to the "O" position. If the device

is still not functioning after the switch replacement, contact Quadralite brand's authorized service center.

Warranty and Maintenance

1. Turn the device off immediately if it works improperly or when you find that the lamp's casing or the

power cord is damaged.

2. Protect the lamp against shocks, impacts and dustiness, and regularly keep the casing clean.
3. The lamp may heat up during operation. This is normal especially when you use the maximum light

output.

4. Repair,   maintenance   and   cleaning   of   the   lamp's   internal   components   may   be   carried   only   by   the

authorized   service   center.   Repairing   the   lamp   outside   the   authorized   service   center   shall   void   the
warranty.

5. Do not use the lamp, if you suspect that it is damaged, dusted or exposed to excessive moisture.

In such a case, immediately contact the authorized Quadralite service center to evaluate the device's
suitability for further operation.

6. Before   attempting   to   transport   the   lamp,   you   must   always   disconnect   it   from   the   power   source

and wait until it completely cools down.

7. Clean the lamp only if it is turned off and disconnected from the power source. Clean the device with a

dry brush, and in the case of stubborn marks with a slightly moistened, soft cloth. Do not immerse the
device in water and do not use detergents to clean its surface. Only surface cleaning is possible!

Technical Data

Name:

Quadralite VideoLED 600

Type:

Continuous Light Studio Lamp

Light Source:

LED Diode,

Output:

60W

Brightness Adjustment:

smooth

Color Temperature: 

5400K (±100K)

Accessories Mount:

Bowens

Cooling:

passive (radiator) and active (cooling fan)

Fuse: 

10A

Power Supply:

200~240V 50Hz

Dimensions:

136 x 127 x 300 mm

Weight:

2.2 kg

Made in China

www.quadralite.pl

[email protected]

Page 4

Summary of Contents for VideoLED 600

Page 1: ...ektywnie wykorzysta jego mo liwo ci Prosimy zachowa niniejsz instrukcj i przechowywa j w miejscu atwo dost pnym dla wszystkich u ytkownik w urz dzenia Spis tre ci Wprowadzenie 1 Bezpiecze stwo 1 Eleme...

Page 2: ...as pracy urz dzenia Elementy te nagrzewaj si a ich dotykanie mo e spowodowa oparzenia Przed przyst pieniem do czynno ci wymagaj cych dotykania LED lub radiatora nale y odczeka do momentu ich ca kowite...

Page 3: ...diody LED 2 Nale y zamocowa urz dzenie na odpowiednim statywie studyjnym przy pomocy mocowania statywowego 6 dopasowa kierunek wiecenia i k t nachylenia lampy oraz dokr ci zacisk 5 Mocowanie modyfikat...

Page 4: ...a ania lub stwierdzenia e obudowa lampy b d kabel zasilaj cy jest uszkodzony 2 Nale y chroni lamp przed wstrz sami uderzeniami i zapyleniem oraz regularnie dba o czysto obudowy 3 Podczas pracy lampa m...

Page 5: ...of the device Table of Contents Introduction 1 Safety 1 Lamp Components 2 Included Accessories 3 Optional Accessories 3 Lamp Use Operation 3 Preparing the Lamp for Operation 3 Attaching Light Modifier...

Page 6: ...t would require you to touch LED diodes or the radiator you should wait until they cool down completely minimum 30 minutes Do not mount filters diffusers or other accessories directly on the LED diode...

Page 7: ...y damage to the equipment Preparing the Lamp for Operation 1 Remove the LED diode s cover 2 Mount the device onto an appropriate studio tripod using a tripod mount 6 set the light beam direction and t...

Page 8: ...aged 2 Protect the lamp against shocks impacts and dustiness and regularly keep the casing clean 3 The lamp may heat up during operation This is normal especially when you use the maximum light output...

Reviews: