Wiring Wireless Control to Tank Assembly…
Grey: Retract Solenoid Operation Post, Blue: Extend Solenoid Operation Post, Orange: Cap off (not used),
Red: Solenoid Power Stud w/ Copper Strip, Black: Ground (to solenoid mounting stud to tank body).
Two screws can be mounted
at any corner, take care to
avoid plastic reservoir.
Plumbing of Hydraulic Lines…
1pt or Drive Leg: If the tank hoses are not already connected to the leg, the left fitting on the tank
assembly goes to the bottom fitting on the Bigfoot Jack, (the longest hose.)
2pt Slave Legs: Install “T” fittings at the drive leg’s ports, run the short hoses from the tank assembly to
the “T” fittings, run the longer hoses to the slave or driven leg.
Hydraulic Line Bleeding Process…
Prior to hooking up both slave leg hydraulic lines; install the retract line only, leave the extend line un-
attached at the slave leg and place the line in a container (the same container used for filling the reservoir
works well). After filling the reservoir and installing the controls and power (may be temporary), press the
extend button on the control to extend the jacks for a moment until the container starts to be filled with
the fluid from the slave leg’s extend line. This means all the air is removed from that line and cannot be
internally trapped in the system. Install the extend line to the slave leg and continue to run the jacks to full
extension and leave for a moment (typically 15 minutes) and back down again. After doing so, top off the
hydraulic reservoir and process complete!