TABLE OF CONTENTS

     Safety Alert Key:

• 

DANGER! 

Indicates a hazardous situation which, if not avoided will result in death or serious injury.

• 

WARNING!

 Indicates a hazardous situation which, if not avoided could result in death or serious injury.

• 

CAUTION! 

Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

• 

NOTICE:

 Indicates practices which may cause damage to the appliance or to property.

Quadra-Fire is a registered trademark of Hearth & Home Technologies.

NOTE:  This installation must conform with local codes. In the 

absence of local codes you must comply with the UL1482-07, (UM) 

84-HUD and NPFA211 in the U.S.A. and the ULC S627-00 and 

CAN/CSA-B365 Installation Codes in Canada. 

NOT APPROVED 

FOR MOBILE HOME INSTALLATIONS IN CANADA!

Important Safety Information

..............

3

A.  Appliance Certification ......................................................3

B.  BTU & Efficiency Specifications........................................3

C.  Mobile Home Approved (USA ONLY) ............................... 3

D.  Glass Specifications .........................................................3

E. Non-Combustible Materials ...............................................3

F. Combustible Materials ........................................................3

Getting.Started.....................................

4

A. Design and Installation Considerations .............................4

B. Fire Safety .........................................................................4

C.  Negative Pressure ............................................................5

D.  Tools And Supplies Needed ..............................................5

E.  Inspect Appliance and Components .................................5

F. Install Checklist ..................................................................6

Dimensions and Clearances

...............

7

A.  Appliance Dimensions ......................................................7

B. Clearances to Combustibles ..............................................8

C.  Locating Your Stove & Chimney .......................................9

D.  Chimney Termination Requirements ................................9

E.  2-10-3 Rule  ......................................................................10

Chimney Systems

..............................

11

A.  Venting Components  .......................................................11

B.  Chimney Systems .............................................................11

C. Installing Chimney Components ........................................13

Appliance Set-Up

...............................

14

A.  Hearth Protection Requirements ......................................14

B. Outside Air Kit Installation  .................................................15

C.  Blower (Optional) ..............................................................16

D.  Reversible Flue Collar and Horizontal Flue Heat Shield ..17

Mobile.Home.Installation...................

18

Accessory List

...................................

19

Summary of Contents for XPLRMED-PBK

Page 1: ...sonnel Hearth Home Technologies recommends NFI certified professionals or technicians supervised by an NFI certified professional HOT SURFACES Glass and other surfaces are hot during operation AND coo...

Page 2: ...Canada NOT APPROVED FOR MOBILE HOME INSTALLATIONS IN CANADA 1 Important Safety Information 3 A Appliance Certification 3 B BTU Efficiency Specifications 3 C Mobile Home Approved USA ONLY 3 D Glass Spe...

Page 3: ...tained The appliance must be properly grounded to the frame of the mobile home with 8 copper ground wire and chimney must be listed to UL103 HT or a listed UL 1777 full length six inch 152mm diameter...

Page 4: ...with unit Do NOT Overfire If appliance or chimney connector glows you are overfiring Any such action that may cause a fire hazard WARNING Fire Risk Hearth Home Technologies disclaims any responsibilit...

Page 5: ...ipped or sealed Attic mounted duct work and air handler joints and seams taped or sealed Basement installations should be avoided WARNING Negative pressure can cause spillage of com bustion fumes soot...

Page 6: ...earance Chimney meets recommended height requirements 14 16 feet Roof flashing installed and sealed Terminations installed and sealed Clearances Section 3 Pg 7 Combustible materials not installed in n...

Page 7: ...19 1 2 26 3 4 Figure 7 1 Front View Figure 7 2 Side View 12 1 4 20 1 16 7 15 16 27 28 15 16 Figure 7 2 Top View 29 3 25 7 8 22 3 16 Figure 7 4 Side View with horizontal fl ue 3 Dimensions and Clearanc...

Page 8: ...1397 Explorer II 10 1 2 267 6 1 2 165 20 1 4 514 6 1 2 165 7 178 17 1 4 438 55 1397 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS in inches Millimeters NOTE A C and F Dimensions are to the center of th...

Page 9: ...mney should Install through the warm space enclosed by the build ing envelope This helps to produce more draft espe cially during lighting and die down of the fire Penetrate the highest part of the ro...

Page 10: ...Minimum 3 ft 91cm Minimum Wall or Parapet Flat Roof E 2 10 3 Rule These are safety requirements and are not meant to assure proper flue draft This appliance is made with a 6 inch 152mm diameter chimn...

Page 11: ...l black or 26 gauge blued steel or an approved air insulated double wall venting pipe Thimble A manufactured or site constructed device installed in combustible walls through which the chimney connect...

Page 12: ...utside dimension frame from 2 x 2 framing lumber to fit into wall opening Inside opening of frame should be no less than 14 inch x 14 inch 356mm x 356mm Figure 12 1 4 Attach the wall spacer to the chi...

Page 13: ...ctors must conform to each other to ensure a proper fit and seal Flue Gas Direction Crimped End Toward Appliance Secure pipe sections with a minimum of 3 screws Figure 13 2 Chimney Connector Stove Pip...

Page 14: ...ary to install a floor protector Type I of a minimum of 3 8 inch 9 5mm thick metal clad millboard or equivalent a minimum of 16 inches 406mm in front of glass and 8 inches 203mm to both sides of the f...

Page 15: ...a 2 Phillips screw driver attach the flex adapter to the stove using 4 screws Figure 15 1 15 2 3 Floor Rear Installation Cut a 4 inch 102mm hole in outside wall or floor to accommodate outside air pip...

Page 16: ...lts securing blower onto outer wall of appliance 4 Place the bracket containing the snap disc and magnet under the bottom left rear corner See Owner s Manual for detailed operating instructions for th...

Page 17: ...lips and convection chamber top 2 Phillips 2 Remove 1 bolt from each side of the flue transition and retrieve nuts attached to bolts 3 Turn flue transition to horizontal position Inspect rope gasketin...

Page 18: ...a 6 inch 152mm factory built chimney conforming to CAN ULC 629M STANDARD FOR FACTORY BUILT CHIMNEYS 6 Follow the chimney and chimney connector manufacturer s instructions when installing the flue syst...

Page 19: ...REPAIR Y Nut Ser Flange Small 1 4 20 Pkg of 24 226 0130 24 Y Screw Pan Head Philips 8 32 X 3 8 Pkg of 40 225 0500 40 Y Screw Sheet Metal 8 X 1 2 S Grip Pkg of 40 12460 40 Y Washer 1 4 Sae Pkg of 24 2...

Page 20: ...eration DO NOT DISCARD Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com CONTACT INFORMATION This prod...