Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. U • 1/12
28
Figure 7.9
Top Vent - Vertical Termination
Venting with 2 elbows (NG)
Top Vent - Vertical Termination
Venting with 2 elbows (Propane)
Note:
There MUST be a 25%
reduction in total H when
using fl ex vent except when
using the simple up and out
installation (see Figure 5.3).
Note:
Use SLP Series
components only.
V
1
Minimum
H
1
Maximum
V
2
V
1
+ V
2
Minimum
90 Elbow
1 ft.
305 mm
*
*
1/2 ft.
152 mm
2 ft.
610 mm
*
*
1-1/2 ft.
457 mm
3 ft.
914 mm
*
*
2-1/2 ft.
762 mm
5 ft.
1.5 m
*
*
3-1/2 ft.
1.1 m
7 ft.
2.1 m
*
*
4-1/2 ft.
1.4 m
15 ft.
4.6 m
*
*
H
1
MAX. =15 ft. (4.6 m)
V
1
+ V
2
+ H
1
MAX. = 40 ft. (12.2 m)
* No specifi c restrictions on this value EXCEPT V
1
+ V
2
+ H
1
cannot exceed 40 ft. (12.2 m)
V
1
Minimum
H
1
Maximum
V
2
V
1
+ V
2
Minimum
90 Elbow
Not Allowed
*
*
1/2 ft.
152 mm
1 ft.
305 mm
*
*
1-1/2 ft.
457 mm
3 ft.
914 mm
*
*
2-1/2 ft.
762 mm
5 ft.
1.5 m
*
*
3-1/2 ft.
1.1 m
7 ft.
2.1 m
*
*
4-1/2 ft.
1.4 m
15 ft.
4.6 m
*
*
H
1
MAX. =15 ft. (4.6 m)
V
1
+ V
2
+ H
1
MAX. = 40 ft. (12.2 m)
* No specifi c restrictions on this value EXCEPT V
1
+ V
2
+ H
1
cannot exceed 40 ft. (12.2 m)
H
1
V
1
V
2