Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. U • 1/12
26
Figure 7.6
Top Vent - Horizontal Termination
Venting with 3 elbows (NG)
Top Vent - Horizontal Termination
Venting with 3 elbows (Propane)
Note:
There MUST be a 25%
reduction in total H when
using fl ex vent except when
using the simple up and out
installation (see Figure 5.3).
Note:
Use SLP Series
components only.
V
1
Minimum
H
1
+ H
2
Maximum
90 Elbow
0 ft.
0 mm
1/2 ft.
152 mm
1 ft.
305 mm
1-1/2 ft.
457 mm
2 ft.
610 mm
2-1/2 ft.
762 mm
4 ft.
1.2 m
3-1/2 ft.
1.1 m
6 ft.
1.8 m
H
1
+ H
2
MAX. =14 ft. (4.3 m)
V
1
+ V
2
+ H
1
+ H
2
MAX. = 40 ft. (12.2 m)
V
1
Minimum
H
1
+ H
2
Maximum
90 Elbow
Not Allowed
1/2 ft.
152 mm
0 ft.
0 mm
1-1/2 ft.
457 mm
2 ft.
610 mm
2-1/2 ft.
762 mm
4 ft.
1.2 m
3-1/2 ft.
1.1 m
6 ft.
1.8 m
H
1
+ H
2
MAX. =14 ft. (4.3 m)
V
1
+ V
2
+ H
1
+ H
2
MAX. = 40 ft. (12.2 m)
H
2
H
1
V
2
V
1