background image

 2 

 

 

 

 

                        7082-132H 

 

 

 

             July 1, 2015

MT. VERNON E2 INSERT

B. Sample of Serial Number / Safety Label

LOCATION:  Behind right cast side panel

Serial No.

Model 

Name

Test Lab & 
Report No.

Mfg. Date

S

A

M

P

L

E

Mt Vernon E2 Pellet Insert

R

SERIAL NO. / NUMÉRO DU

007059

Listed Solid Fuel Room Heater/Pellet Type.  Also suitable for Mobile Home Installation.  This appliance has 

been tested and listed for use in Manufactured Homes in accordance with OAR 814-23-9000 through 

814-23-909.
Appareil de chauffage de combustible solide/de type de boulettes.  Accepté dans l'installation dans les 

maisons mobiles.  Cet appareil a été testé et enregistré pour l'usage dans les Maisons Mobiles en accord 

avec OAR 814-23-9000 jusqu'à 814-23-909.

PREVENT HOUSE FIRES / 

PRÉVENTION DES FEUX DE MAISON

Install and use only in accordance with manufacturer's installation and operating instructions.  Contact local 

building or fire officials about restrictions and inspection in your area.

WARNING - FOR MOBILE HOMES:  Do not install appliance in a sleeping room.  An outside combustion air 

inlet must be provided.  The structural integrity of the mobile home floor, ceiling and walls must be maintained.  

Refer to manufacturer's instructions and local codes for precautions required for passing chimney through a 

combustible wall or ceiling.  Inspect and clean vent system frequently in accordance with manufacturer's 

instructions.  DO NOT CONNECT THIS UNIT TO A CHIMNEY SERVING ANOTHER APPLIANCE.  Use a 3" 

or 4" diameter type "L" or "PL" venting system.
Installez et utilisez en accord avec les instructions d'installation et d'opération du fabricant. Contactez le 

bureau de la construction ou le bureau des incendies au sujet des restrictions et des inspections d'installation 

dans votre voisinage. Ne pas obstruez l'espace en dessous de l'appareil.

AVIS - Pour Les Maisons Mobiles:  Ne pas installer dans une chambre à coucher. Un tuyau extérieur de 

combustion d'air doit être installé et ne doit pas être obstrué lorsque l'appareil est en usage. La structure 

intégrale du plancher, du plafond et des murs de la maison mobile doit être maintenue intacte.  Référez vous 

aux instructions du fabricant et des codes locaux pour les précautions requises pour passer une cheminée à 

travers un mur ou un plafond combustibles, et les compensations maximums.  Inspectez et nettoyez la 

cheminée fréquemment. Ne pas connecter cet appareil à une cheminée servant un autre appareil.  Utilisez 

systèm de ventilation "L" ou "PL" diamètre 76mm ou 102mm

Conforms to ASTM Std E1509-12. Certified to ULC S628-93. Room Heating Pellet BurningType,  (UM) 

84-HUD FOR USE ONLY WITH PELLETIZED WOOD  FUEL. Do not use any other type of fuel.  
Input Rating: 55,000 Btu's/hr.  Electrical Rating:115 VAC, 60 Hz, Start 2.9 Amps, Run 2.45 Amps.  Route 

power cord away from unit.  Do not route cord under or in front of appliance.  Do not obstruct the space 

beneath the heater.
DANGER:  Risk of electrical shock.  Disconnect power supply before servicing.  Replace glass only with 5mm 

ceramic.  To start, turn dial control to desired setting and set thermostat above room temperature, the stove 

will light automatically.  To shutdown, turn dial control to OFF or set thermostat below room temperature.  For 

further instruction refer to owner's manual.  Keep viewing doors tightly closed during operation.  Keep viewing 

and ash removal doors tightly closed during operation.

Conforme à la norme ASTM E1509-12 Std. Certifié à la norme ULC S628-93. Room Heating Pellet Burning 

Type, (UM) 84-HUD POUR USAGE AVEC LES BOULETTES DE BOIS.  N’utiliser aucun autre genre de 

combustible.  
Puissance de Rendement: 55,00 Btu's/hr.  

Puissance Électrique: 115 VAC, 60 Hz, Début 2.9 Amps, Courir 

2.45 Amps, Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessus ou en 

dessous de l'appareil.  Ne pas bloquer l’espace au dessous de l’appareil

.  

DANGER: Il y a risque de décharge électrique.  Déconnectez le fil électrique de la prise de contact avant le 

service.  Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible chez votre fournisseur.  

Pour commencer, tournez la molette de réglage à la température désirée et réglez le thermostat au-dessus de 

la température ambiante, le poêle s'allumera automatiquement. Pour éteindre, tournez la molette de réglage 

sur OFF ou réglez le thermostat dessous de la température ambiante.  Pour des instructions supplémentaires, 

référez vous au manuel du propriétaire.  Gardez la porte d'ouverture et la porte des cendres fermées 

hermétiquement durant l'opération.

7082-133B

HOT WHILE IN OPERATION DO NOT TOUCH, KEEP 

CHILDREN, CLOTHING AND FURNITURE AWAY. 

CONTACT MAY CAUSE SKIN BURNS.  SEE NAMEPLATE AND INSTRUCTIONS.  

CAUTION:

CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. 

GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE 

L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES 

BRÛLURES À LA PEAU.  VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS.  

ATTENTION:

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS / ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES

AS A BUILT-IN UNIT / COMME APPAREIL INSÉRÉ

A  Top of Hopper / Haut de la trémie 

Top/Rear Vent / Des Conduits Du Haut/Arrières 

3 in  [76mm]

B  Side of Outside Skin / Côté de Enveloppe extérieure 

Top/Rear Vent / Des Conduits Du Haut/Arrières 

2 in  [51mm]

C   Vent Pipe to Combustible / Des Conduits de combustible 

Top/Rear Vent / Des Conduits Du Haut/Arrières 

3 in  [76mm]

D  Cast Side to Side Wall / Moulage Side à Wall Side 

Top/Rear Vent / Des Conduits Du Haut/Arrières 

6 in  [152mm]

D

B

B

C

A

MASONRY OR ZERO CLEARANCE / DÉGAGEMENT DE LA MAÇONNERIE OU DÉGAGEMENT ZÉRO*

SIDE W

A

LL

 / MUR LA

TÉRAL

MANTEL / MANTEAU

C

A

B

D

E

A Cast Side to Side Wall / Moulage Side à Wall Side 

6 in  [152 mm]

B Insert top to face trim / Insérez le dessus de la garniture de façade 

0 in  [0 mm]

C Insert side to face trim / Insérez le côté de la garniture de façade 

0 in  [0 mm]

D Hearth extension from door opening / Prolongement d’âtre depuis l’ouverture de la porte devant 

6 in  [152 mm]

E Hearth extension from side of door opening / Prolongement d’âtre depuis le côté de l’ouverture de la porte 

6 in  [152 mm]

U.S. ENVIRONMENTAL PROTECTION AGENCY

Certified to comply with 2015 particulate emission standards at 0.5 g/hr EPA Method 28 and 

5G. Not approved for sale after May 15, 2020

This wood heater needs periodic inspection and repair for proper operation. Consult the 

owner’s manual for further information. It is against federal regulations to operate this wood 

heater in a manner inconsistent with the operating instructions in the owner’s manual.

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE

Made in U.S.A. of US and imported parts.

Fabriqué aux États-Unis-d’Amérique par des pièces d’origine américaine et pièces importées.

2015

2016

2017

JAN

FEB

MAR

APR

MAY

JUN

JUL

AUG

SEP

OCT

NOV

DEC

1445 North Highway, Colville, WA  99114

www.quadrafire.com

Manufactured by:Fabriqué par

Owners Manual

Install Manual

O-T L

Tested and 

Listed by

Portland

Oregon USA

OMNI-Test Laboratories, Inc.

C

US

Report:

 061-S-84-2 

A. Congratulations

Hearth & Home Technologies welcomes you to our tradition 
of excellence!  In choosing a Quadra-Fire appliance, you 
have our assurance of commitment to quality, durability, and 
performance.

This commitment begins with our research of the market, 
including ‘Voice of the Customer’ contacts, ensuring we 
make products that will satisfy your needs. Our Research 
and Development facility then employs the world’s most 
advanced technology to achieve the optimum opera-

tion of our stoves, inserts and fi replaces.  And yet we are 
old-fashioned when it comes to craftsmanship.  Each unit 
is meticulously fabricated and gold and nickel surfaces are 
hand-fi nished for lasting beauty and enjoyment.  Our pledge 
to quality is completed as each model undergoes a quality 
control inspection.      

We wish you and your family many years of enjoyment in 
the warmth and comfort of your hearth appliance. Thank 
you for choosing Quadra-Fire.

NOTE:  Clearances may only be reduced by means 

approved by the regulatory authority having jurisdiction

and Welcome to the Quadra-Fire Family

!

Summary of Contents for MTVI-E2-MBK

Page 1: ...sted and approved for wood pellets and shelled corn only Burning of any other type of fuel voids your warranty NOTE To obtain a French translation of this manual please contact your dealer or visit www quadrafire com 00Pour obtenir une traduction française de ce manuel s il vous plaît contacter votre revendeur ou visitez www quadrafire com CAUTION Check building codes prior to installation Install...

Page 2: ...lectrique de la prise de contact avant le service Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible chez votre fournisseur Pour commencer tournez la molette de réglage à la température désirée et réglez le thermostat au dessus de la température ambiante le poêle s allumera automatiquement Pour éteindre tournez la molette de réglage sur OFF ou réglez le thermostat dessous de ...

Page 3: ...ructions 8 A Fire Safety 8 B Non Combustible Materials 8 C Combustible Materials 8 D Fuel Material and Fuel Storage 8 E Before Your First Fire 9 F Filling the Hopper 9 G User Dial Control 9 H Normal Startup Sequence 9 I Firepot Purge 9 J Shutdown 9 K Fire Characteristics 10 L Your Pellet Appliance s General Operating Parts 10 M LED Color Coding Chart and Explanation 11 N Restarting the Appliance 1...

Page 4: ...ruction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty period for parts and labor for covere...

Page 5: ...MT VERNON E2 INSERT WARRANTY CONDITIONS This warranty is void if LIMITATIONS OF LIABILITY 8 K N N OQ R U Z 8 88 U 8 U Q 8 N N Q Z R N U Q 8 R Z N N 88 N U Q 8 N O K WARRANTY EXCLUSIONS N Z N _ q _ q _ q _ q _ q _ q _ q _ q _ q ...

Page 6: ...g appliance plug it back in and repeat Priming is only needed for first fire or starting fire on empty hopper HEAT SETTING HEAT SETTING O F F HI LO HEAT SETTING HEAT SETTING O F F HI LO HEAT SETTING HEAT SETTING O F F HI LO 2 Choose Setting LO HI Green LIGHT will be gin flashing and stove will start It may take as long as 10 minutes to achieve a fire in the firepot Turning the knob or thermostat t...

Page 7: ...ire Risk Hearth Home Technologies disclaims any responsibility for and the warranty will be voided by the following actions B BTU Efficiency Specifications C Glass Specifications This stove is equipped with 5mm ceramic glass Replace glass only with 5mm ceramic glass Please contact your dealer for replacement glass D Electrical Rating 115 VAC 60 Hz Start 2 9 Amps Run 2 45 Amps E Mobile Home Approve...

Page 8: ...Higher Ash Content Material Hardwoods with a high mineral content Fuel that contains bark Standard grade pellets or high ash pellets Lower Ash Content Material Most softwoods Fuels with low mineral content Most premium grade pellets Corn A 2 1 mix of pellets to corn is approved but may re quire the firepot to be cleaned more frequently When using a pellet corn fuel mixture it is recommend ed that ...

Page 9: ...ellets are warming on the verge of igniting it NOTE UNIT CAN USE 2 1 PELLET CORN MIXTURE We recommend the use of a 2 1 pellet corn mixture The only change in operation is that the feed rate may require a slight adjustment is not uncommon for the firebox to fill with smoke Once ignition happens the smoke should quickly disap pear During this stage as well as any part during the burn process the fro...

Page 10: ...peration Curing of high temperature paint Open windows for air circulation Odors may be irritating to sensitive individuals CAUTION WARNING HOT SURFACES Glass and other surfaces are hot during operation AND cool down Hot glass will cause burns DO NOT touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as appliance Alert ch...

Page 11: ... or in shutdown During shut down the blowers will shut off when the exhaust temperature has cooled Green 1X Stage 1 Low heat BTU Range 14 620 19 694 Average 19 054 Green 2X Stage 2 Med Low heat BTU Range 22 102 23 506 Average 22 735 Green 3X Stage 3 Med heat BTU Range 30 778 32 680 Average 31 603 Green 4X Stage 4 Med Hi heat BTU Range 38 576 42 914 Average 40 665 Green 5X Stage 5 Hi heat BTU Range...

Page 12: ...llet Fuel or High Ash Pellet Fuel QuadraFire recommends setting the appliance and leaving at a 4 trim setting From our testing lower BTU fuels result in large clinkers in the bottom of the firepot during normal operation Using this type of fuel will increase the recommended firepot cleaning interval If Burning Softwood Pellet Fuel QuadraFire recommends starting at a 2 trim setting and adjusting ba...

Page 13: ...ay To cancel the temporary setting at any time press RUN SCHEDULE Program Schedule Override permanent Press HOLD to permanently adjust the temperature This will override the temperature settings for all time periods The Hold feature turns off the program schedule and al lows you to adjust the thermostat manually as needed Whatever temperature you set will be maintained 24 hours a day until you man...

Page 14: ...the blowers to quiet them down No The most often cause of noisy blowers is from the impellers becoming dirty over time See maintenance and service section for maintaining and servicing What is the metal object with the bend in it that came inside the plastic bag It is a clean out tool used to help clean the firepot and remove any jams in the rare event they occur in the feed tube Why is there a bl...

Page 15: ...ocate a dealer We recommend annual service by a qualified dealer A Proper Shutdown Procedure Turn dial control to OFF let appliance completely cool and exhaust blower must be off Now you can unplug appli ance before servicing Cleaning or Inspection Frequency Daily Weekly Monthly Yearly Firepot As needed OR X Ash Removal from Firebox About 5 bags of fuel depend ing on ash build up OR X Glass When c...

Page 16: ... the 2 side latches Clinkers filling the ash pan will have to be cleaned out more often than ash Ash Disposal Ashes should be placed in a steel container with a tight fitting lid The container of ashes should be moved outdoors immediately and placed on a non combustible floor or on the ground well away from combustible materials pending final disposal If the ashes are disposed of by burial in soil...

Page 17: ... the majority of the ash Be sure to vacuum the back of the baffle also Inspect the drop tube and remove any residue build up in the drop tube Figure 17 3 c Assemble the crevice tool from the micro cleaning kit to attach to a Shop Vac Figure 17 4 d Use the crevice tool to finish cleaning the heat exchanger fins It is critical that the 2 exhaust exits at the back of the firebox floor left and right ...

Page 18: ...the appliance is allowed to cool b Open the front cast door and cycle the ash removal handle these should be inspected for functionality c Inspect for any degradation or deformation As the springs heat up and cool down they can lose tension If there is a gap showing above the firepot bottom approximately 1 16 inch 1 59mm or more it means the springs have lost their tension Lost tension cannot keep...

Page 19: ...he glass and firebox should be inspected periodically to make sure there is a good seal If the gasket is frayed or damaged replace with a new one 8 Cleaning Exhaust System Requires No Lubrication Frequency See chart on pg 15 By Homeowner a Be sure the appliance is allowed to cool b Remove blower per replacement instructions c Use a soft brush and vacuum to clean the propellers d Vacuum out exhaust...

Page 20: ...rmation on how to handle a chimney fire In the event of a soot or creosote fire close the firebox door exit the building immediately and contact the proper fire authorities DO NOT under any circumstances re enter the building E High Ash Fuel Content Maintenance Frequency Daily By Homeowner If the ash build up exceeds the half way point in the firepot or clinkers are adhering to the sides of the fi...

Page 21: ...2 5 Rock the top of the blower slightly and lift up The blower will pass out the left side of the appliance Note You may need to loosen the surround to move it out of the way 6 Install replacement blower by placing the bottom flange into the opening first then rotate blower up into position 8 When the blower is properly positioned the latch will engage the notch to hold the blower in place Figure ...

Page 22: ...witch wires for integrity Safety snap disc is tripped Check to make sure convection blower wires are connected and reset snap disc located on RH side of appliance Clean inspect convection blower and convection air path Feed System is jammed Inspect and un jam the feed assem bly Feed motor not plugged in Reconnect feed motor Igniter not plugged in Connect the igniter wires Defective igniter Replace...

Page 23: ... Replace blower Exhaust probe not sensing correct temperature Secure the exhaust probe to exhaust blower housing keeping its wire away from hot surfaces Control board is defective Replace control board Convection Blower fails to shut off Wire short between blower and ground Control board is defective Repair wire and replace control board Exhaust blower fails to start and or red flashes 6X indicati...

Page 24: ...fuel spilling over the fire pot and or excessive flame Dirty Appliance Clean unit including the firepot exhaust path and venting system Feed Motor locked on Follow corrective action for feed motor not turning off Black soot on the side of the house Dirty Appliance Clean unit including the firepot exhaust path and venting system Exhaust termination cap too close to the structure Extend the terminat...

Page 25: ...t terminal end to control board Failed component Replace exhaust probe securing it to exhaust blower housing keeping wire away from hot surfaces 4 Red Flashes Missed Ignition Hopper empty Fill the hopper Feed motor doesn t turn Inspect feed motor circuit hopper lid must be closed vacuum switch must be closed snap disc closed and feed motor must be plugged in Clear jam in feed tube Dirty appliance ...

Page 26: ...nvection Blower The convection blower is mounted at the bottom left of the appliance The convection blower pushes heated air through the heat exchange system into the room 4 Feed System The feed system is located on the right side of the appliance and can be removed as an entire assembly The hollow feed spring auger pulls pellets up the feed tube from the hopper area and drops them down the feed c...

Page 27: ...RNON INSERT E2 Beginning Manufacturing Date Feb 2014 Ending Manufacturing Date Active Pellet Insert MTVI E2 CSB MTVI E2 MBK MTVI E2 PMH Part number list on following pages 06 15 39 38 37 36 35 34 33 32 31 30 29 28 27 8 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 ...

Page 28: ...101MBK Porcelain Mahogany 7036 101PMH Sienna Bronze 7036 101CSB 4 Catch Clip 7036 146 5 Elbow Catch 7000 393 6 Bracket Catch 7036 145 7 Backer Side Window 414 0280 8 Side Matte Black 7036 103MBK Porcelain Mahogany 7036 103PMH Sienna Bronze 7036 103CSB 9 Gasket Door Rope SRV7034 177 Y 10 Hinge Male 7034 138 11 BafÀe SRV7034 263 Y 12 Latch BafÀe 7034 149 13 Hinge Pin Retainer 7036 112 14 Pin Hinge S...

Page 29: ...mbly 21 W x 14 H 7034 007 Y 19 3 Hinge Female 450 2910 19 4 Door Latch Assembly 413 5200 Gasket Channel 3 Mm X 32 Field Cut to Size 10 Ft 7000 377 10 Y 20 Ash Pan Door 7034 133 21 Ash Pan Assembly SRV7034 069 Twin Ball catch SRV7000 532 Y 22 Intake Shield 7034 224 Y 23 Firepot Riser Assembly SRV7080 002 23 1 Firepot Assembly SRV7034 072B Y 23 2 Gasket Firepot 7034 190 Y 23 3 Spring Pkg of 4 7000 5...

Page 30: ...tor Blower Combustion Between Housing Motor SRV7080 107 Y 31 Snap Disc L250 Manual Reset SRV230 1290 Y 32 Flue Collar Assembly SRV7082 013 33 Gasket Flue Adpator Flange 7036 180 Y 34 Top Vent Adapter TPVNT 4 35 Convection Blower SRV7080 105 Y 36 Feed Assembly SRV7080 010 Y Feed Spring Assembly Only SRV7001 046 Y Gasket Feed Motor 7034 144 Feed Motor 812 4421 Y 37 Elbow Catch 7000 393 38 Magnetic S...

Page 31: ...og Set 2 Pc Sold as set only LOGS 60 AE B Y Outside Air Kit OAK 3 Top Vent Adapter TPVNT 4 Surround Std Panel For Cast Trim SP MTVS CST Component Pack 7036 041 Surround Std Panel w Gold Trim SP MTVS GD Component Pack 7036 042 Trim Panel Set Gold 250 4660 Surround Std Panel w Nickel Black Trim No Longer Available SP MTVS NB Component Pack 7036 042 Trim Set Black Nickel 7019 027 Trim Cast Matte Blac...

Page 32: ...ville WA 99114 Division of HNI INDUSTRIES Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com This product may be covered by one or more of the following patents United States 5341794 5263471 6688302 7216645 7047962 or other U S and foreign patents pending We recommend that you record the following pert...

Reviews: